:TRACe:MARKer:BANDwidth:CALCulate

command/query

Gets or sets the Band Power summation method (either mean or RMS).

Command Syntax:

:TRACe[1:N]:MARKer[1:N]:BANDwidth:CALCulate <bandCalc>

<bandCalc> ::= "Mean" | "Rms"

Query Syntax:

:TRACe[1:N]:MARKer[1:N]:BANDwidth:CALCulate?

Returns ::= "Mean" | "Rms"

Remarks:

<none>

Example:

:TRAC:MARK:BAND:CALC "Mean"

Version:

13.01 or later

.NET Equivalent:

For more operation and usage information, see:

Agilent.SA.Vsa.Interfaces.Marker.BandCalc

Agilent.SA.Vsa.MarkerBandCalc

 

Copyright © 2000-2013 Agilent Technologies, Inc.