:TRACe:MARKer:BANDwidth:TYPE

command/query

Gets or sets the Band Power base calculation (either power or density values).

Command Syntax:

:TRACe[1:N]:MARKer[1:N]:BANDwidth:TYPE <bandType>

<bandType> ::= "Power" | "Density"

Query Syntax:

:TRACe[1:N]:MARKer[1:N]:BANDwidth:TYPE?

Returns ::= "Power" | "Density"

Remarks:

<none>

Example:

:TRAC:MARK:BAND:TYPE "Power"

Version:

13.01 or later

.NET Equivalent:

For more operation and usage information, see:

Agilent.SA.Vsa.Interfaces.Marker.BandType

Agilent.SA.Vsa.MarkerBandType

 