Agilent Resolutions Version 5.2.0.861 CD Readme file

 

 

(c) Agilent Technologies, 2012. All rights reserved.

 

This document provides the following information:

 

  

 

 

Agilent Resolutions Version 5.2.0.861 CD Contents

 

Resolutions Pro v5.2.0.861 employs Microsoft™ Installer (Windows Installer) deployment systems.  The Installation CD contains the files required to install Resolutions Pro v5.2.0.861 and update the firmware of the Agilent 600-IR series FT-IR spectrometers. There are three discs to install which should be installed in order. See installation instructions below before installing.

Install disc 1:  Imaging Drivers v1.0 (for “Type B FPA” imaging system only)

Install disc 2: Resolutions Pro v5.2.0.861

Install disc 3: Sample Data and Sample Spectral Libraries

Install disc 4: Resolutions Pro Help

 

Note: Non-Imaging Resolutions Pro software installation will consist of three CDs.

Imaging Resolutions Pro software will consist of four CDs.

What's New in Version 5.2.0.861?

 

-   Support for “Type B” Focal Plane Array (FPA) detectors. These are characterized by three cables coming out of the FPA back panel. This is only supported under Windows 7 (32bit)

Support for existing “Type A” FPAs, with two cables out the rear of the FPA will be maintained. Type B FPA imaging systems will require a new “imaging drivers” CD to be installed prior to the installation of Resolutions Pro. The installation for “Type A” FPAs will remain unchanged and by supported under both XP (SP3, 32bit) and Windows 7 (32bit)

-   Support for the operation of Resolutions Pro (Imaging excluded) in restricted user modes. Imaging is onl supported under Administrator mode.

 

Users upgrading from version 5.0 will also observe:

 

-Rebranded

Some components of the Resolutions Pro software have been rebranded to the new Agilent format.

 

-Source Life

Firmware enhancements to improve source life

 

-Compatibilty

Compatible with Windows 7 (32bit) and XP (SP3, 32bit) operating systems . Imaging with Type A FPAs is supported under XP (SP3, 32bit) and Windows 7 (32bit) and Imaging with Type B FPAs is supported only under Windows 7 (SP3, 32bit).

 

-Compatible with earlier models

Compatible with FTS-7000(e), 4100, 3600, 3100, 2000, 1000, 800 instruments. Check with your local Agilent office for compatibility with earlier models

 

-Step scan

Support for 680-IR with step scan capability for modules such as us and ns-Time Resolved Spectroscopy, Photoacoustic Spectroscopy, Polymer Stretcher and PEM-IRRAS

 

-Dual A/D mode

For instruments with dual A/D, the ability to monitor two data channels simultaneously in rapid scan mode for applications such as PEM-IRRAS.

 

-Expanded trigger functionality

Trigger In and Trigger Out capability in both Rapid and Kinetics scan modes enabling coupling with external hardware such as LC, GC, TGA.

 

- Source sleep mode

User definable sleep mode to help extend source lifetime.

 

-Expanded configuration view

Expanded live display of Diagnostics and Configuration information

 

Users upgrading from version 4.0 or 4.1 will also observe:

 

-Merged Resolutions and Resolutions Pro.  The Resolutions and Resolutions Pro software packages have been merged into a single comprehensive package; Resolutions Pro.  The user interface has been simplified and improved to ensure that features, previously unique to Resolutions, are now available in the new Resolutions Pro.

 

-New protocol for Software Registration

The Resolutions Pro v5.2 software must be registered online (or offline via web portal) within 60 days of installation or it will stop running. The imaging component of Resolutions Pro v5.2, if installed, must be registered immediately.

 

-New Method Editor

A new Method Editor interface replaces the previous Collection > Scan (or Collect > Rapid Scan) dialogs and includes pre-loaded sample methods for standard transmission, ATR, high resolution, NIR and microscope collects.

 

-Enhanced Main User Interface

The user interface has been significantly enhanced and its layout improved. 

 

-Accessory and Component Recognition

Agilent 600 series FTIR users will be able to take advantage of sample compartment accessory recognition and component recognition.  These features assist and simplify spectrometer setup and help ensure the stored method requirements match the specific hardware configuration of the system.

 

-Performance Tests

A new software interface under Collect > Performance Test allows automated collection of routine instrument performance tests.

 

-New Languages

Software supports English, Japanese, Chinese, Italian, Spanish, French and German languages.

 

-KnowItAll library

 Direct searching of Bio-Rad KnowItAll and ST-Japan libraries. Note: Resolutions Pro Search is not supported in double byte languages, eg., Japanese and Chinese.

 

 

Important Information

 

Agilent Resolutions Pro Version 5.2 is supported on Windows XP (SP3), Windows Vista (SP 2) and Windows 7 operating systems only. All operating systems must be 32-bit ONLY. This software is not supported under earlier operating systems such as the Windows 2000 platform, Windows 98, Me, or NT.  If you currently have one of these operating systems installed on your computer you must upgrade to Windows XP, Vista or Windows 7 before running this software. 

Installing/Upgrading to Resolutions Pro 5.2

 

 

Before you can upgrade to Resolutions Pro 5.2 you need to know:

1. What version of Windows you are running,

2. The FTIR software version you are currently using, and

3. The FTIR hardware you are using.

 

>>>To find out what version of Windows you are running:

1. Right-click on the computer icon on the desktop.

2. Select Properties from the menu. The General tab page should be active. The operating system is given directly under "System".

 

>>>To find out what release of FTIR Software you are running:

1. Start Resolutions Pro.

2. Select Help/About Resolutions Pro. The splash screen shows the release number.

 

>>>To find out what FTIR hardware you are using;

1. Refer to the model label on the front of the FTIR spectrometer.

 

Refer to Resolution Pro software installation manualfor full details on installing Resolutions Pro 5.2.0.861 and forusers upgrading from Resolutions Pro 4.1 or. It is important these instructions are followed carefully.

 

  Other applications included

 

The following Resolutions Pro tools can be run by selecting Start > Programs > Agilent Resolutions > "Program Name", or run from within the menus of Resolutions Pro;

 

Autosampler:  Software to support the microscope stage autosampler.

Average:      Calculates the average of selected spectra in a document.

Convert:      Converts a Multispectral document (.bsp) to JCAMP, comma separated value (csv), GRAMS, or Bio-Rad Sadtler SearchMaster formats.

EasyID:       Simple software for collection and comparison of IR data used in a Quality Control environment. NOTE: this tool must be purchased separately from Resolutions Pro.

Imaging Kinetics:  Collects a set of Image Data files at specified time intervals.

SNIFTIRS:     Collects interleaved scans and co-adds blocks of data for electrochemical experiments.

Simple FTIR:  Reduced User Interface with only basic controls; Sample Collect, Open and Print.  Administrator may setup and manage methods used.

 

The following Resolutions Pro tool can be run by selecting File > Run from within Resolutions Pro:

 

RMS Noise:    Calculates Root Mean Square Noise for displayed spectra within a user defined range.

 

For a standard install location this file can be found here; C:\Program Files\Varian\Resolutions\bin