Software Status Bulletin
Chemstation ChemStation (G2070BA)
Known Problem Report as of May 6 2010 10:13AM
Preface
-------------------------
This Software Status Bulletin (SSB) documents all known problems in the software
product designated above. The SSB is derived from Known Problem Reports (KPR)
which result from user problems that have been classified as documentation
problems or software defects. When a KPR is written, an identifying number is
assigned to it, and the KPR is added to the next edition of the SSB.
User inputs that have been classified as Enhancement Requests are not documented in the SSB. User problems that have been submitted, but that have not been classified by the time the SSB is generated are not included in the SSB.
How to use the SSB
-------------------------
When you experience a problem with a product, first check this SSB to see if the
problem has been reported already, and if there is a temporary workaround
available for the problem, or if the problem has already been fixed by a new
revision. If the problem is not listed in this SSB then you may wish to report
it to the Response Center or to your field support representative.
To determine if your problem is documented in this SSB, first look in the "Keyword Index" section of the SSB. Under each keyword is a listing of one-line descriptions of related KPRs. If any of these sound like yours, locate the KPR # in the "Known Problem Reports" section of the SSB, and read the full KPR. The KPRs in the "Known Problem Reports" section are sorted by KPR #.
There are two sections in the SSB:
Keyword Index: This index is categorized by keyword. For each KPR there is a
brief description and a KPR #. A KPR may be associated with more than one
keyword.
Known Problem Reports: This section contains KPRs, with all the available information relevant to the problem. KPRs in this section are sorted by KPR #.
Keyword Glossary
Keyword Index
1046 FLD cannot be set up from the GUI
KPR#:1153
Signal change in LC Detector during a run
KPR#:38
two MWD in one instrument: problem to control MWD 2 via GUI
KPR#:43
'Fast Reconditioning' enabled in Normal Mode of capillary pump
KPR#:64
with Column flow of 0.00 ul/min no data acquisition
KPR#:89
EMF indicators do not work
KPR#:135
Using flow gradients during Fraction Collection results in Wrong times in Report
KPR#:179
DAD Diagnosis: lamp indicate green, even when lamps off
KPR#:213
Pressure and Leak test in prep. Pump will not finish, unless Press. released
KPR#:287
Flow composition not updated in GUI when loading new method
KPR#:290
G1321A FLD: cuvette is not correctly recognized
KPR#:407
Starlight and FIA: double start pulsing of G1315C
KPR#:416
G1323B colum setting calles negative value in ChemStation column setting
KPR#:451
DAD Calibration history information logged in chemstation.ini
KPR#:454
Using same detector type twice no selection can be set diagnostic
KPR#:457
Sequence table not accepting options of Next Location/Plate
KPR#:471
G1314C VWD Detector diagnostic test results issue
KPR#:472
Fast Comp. Change / Reconditioning disabled after initialization
KPR#:474
"next plate" option using Vial Trays in Fraction Collection mode
KPR#:475
Customized methods for Noise, Wander, Drift issue
KPR#:476
Aborting System Test on LC systems might perform error state
KPR#:487
micro pressure test failed randomly
KPR#:561
injection number in column tag not update for non-switching valve TCC
KPR#:715
ECD detector scaling in online plot 10x larger than in the data file
KPR#:787
G1362A RID Calibration Value cannot be entered
KPR#:1189
Autobalance not accesible after stopping a sequence with AutoBalance off
KPR#:513
Method Overview: wrong value shown for TCC temperature for "as detector cell"
KPR#:670
impossible to enter a maximum pressure of 600 bar into column information
KPR#:775
Fraction Collector settings of the Peak Detectors table are not saved
KPR#:781
Sample scan not acquired in case of spectral range mismatch for VWD G1314D/E
KPR#:1064
attenuation of 4000 cannot be specified for the Analog Output of VWD G1314D/E
KPR#:1065
G1365C/D Detectors not reporting wavelength scan summary
KPR#:1103
when solvent recycling for the RID is used the bottle filling still changes
KPR#:1181
Column Compartment G1316A/G1316B not available if it is part of cluster
KPR#:1213
CTC: Injection volume not displayed on sampler GUI
KPR#:1227
CTC: UI does not display correct plate
KPR#:1228
Solvents not available for selection in the pump timetable for a Preparative Pump
KPR#:1365
the unit for the void volume in the Edit Columns dialog cannot be entered
KPR#:1383
problem with data rate for LC, LC/MS, and CE ChemStation with RC.NET drivers
KPR#:1388
signal description for the RID differs between signals acquired with classic and RC.NET drivers
KPR#:1389
position of the CSV of a TCC G1316X is incorrectly displayed in the Instrument Actuals
KPR#:1393
"Waste" or "Coulmn bypass" runs are causing injection counters to be incremented
KPR#:1399
the valve does not switch to by-pass position for the last injection when using overlapped injection
KPR#:1411
run cannot be stopped/aborted when the injector program is longer than the run time
KPR#:1418
LC RC.NET drivers: progress bar not updated during post-conditioning
KPR#:1421
5890: Data rate 10Hz used, Real Time Plot display is doubled
KPR#:1047
6850 GC feature loss, such as Prep Run, when controlled by Chemstation
KPR#:707
6890 Workstation Internal Software Error
KPR#:415
GC system crashes when view/instrument diagram active in Offline
KPR#:422
6890 FPD is missing the "Air" and "Makeup" Actuals in Edit Parameters
KPR#:848
IQ1.CFG file of 6890/6850 instrument corrupted after regional setting change
KPR#:1167
6890 RC.NET driver: instrument diagram not updated to show configuration
KPR#:1352
6890 RC.NET driver: instrument diagram not updated to show configuration
KPR#:1412
6890N with no tray or ALS is seeing GC Injector Front/Back/Dual as an injection source
KPR#:1461
Initial valve position set to ON before start when it should be OFF; Meth change
KPR#:911
7890A: ALS errors abort sequence; no Retry/Abort option offered
KPR#:914
7890A: Auto Start Macro fails -9999
KPR#:985
7890A: Method modified after loading if run started from GC keyboard start butto
KPR#:1049
7890A Full report does not contain ALS module type information
KPR#:1110
Can Accept Missing Location Vial in Sequence Table
KPR#:1117
7890A: Signal data is not acquired if oven hold time is set to 0.0
KPR#:1151
7890A: need ability to disable method resolution for columns and valves
KPR#:1166
7890A seq aborts part way through run: "AgGC7890Drv" already has ownership"
KPR#:1169
7890A: HeadSpace information not provided in the GLP + Details Report
KPR#:1180
7890A keyboard is locked even though the Software GC Config is set to unlock
KPR#:1186
7890A: Shutdown events are not published to the software GC Status screen
KPR#:1196
7890A does not show the vial number being injected on the sequence screen
KPR#:1198
7890A Runs cannot be started until the GC and injector are idle, view GC Status
KPR#:1239
7890A logbook shows 7693A turret, plunger errors as GCI1 did not start a run
KPR#:1251
7890A Parameter Mismatch error after upgrade
KPR#:1255
GCI1 did not start a run shown in instrument logbook
KPR#:1257
No dialog box presented for 7693A/7890 ALS errors
KPR#:1273
7890A Two inlets with one detector and one injector causes method resolution
KPR#:1283
ALS errors abort sequence; no Retry/Abort dialog box option offered
KPR#:1329
7890A with no tray will display the Sampling Diagram
KPR#:1462
Time stamp errors in LC Chemstation & Chemstore, Win 2000 time format ignored.
KPR#:12
error "no string 8008" in sample information
KPR#:299
'Active signals" comment is chopped in MSD TIC title.
KPR#:308
Agilent Active Splitter will sometimes not start up correctly after installation
KPR#:375
Snapshot is not created if method or sequence name is of 40 characters long
KPR#:448
FIA runs with Dual Loop Autosampler are not reproducible
KPR#:491
Acquiring multi-signal data with low SIM Dwell times causes erroneous data.
KPR#:492
Main root path as data path in Preferences does not work for data acquisition
KPR#:777
Max oven temp not changed after installing column with higher max temperature
KPR#:1178
Run Time Checklist: selected Acquisition only but Data Analysis still occurred
KPR#:1250
ChemStation switches to default path without warning if data path not available
KPR#:1316
sporadically the next run in a sequences will not start
KPR#:1321
report preview or printout from Report Layout does not trigger report history
KPR#:1122
deletion of compound group not tracked in method audit trail
KPR#:1133
CE system: Pressure are not applied correctly
KPR#:263
CE: Online plot does not adjust into negative not into y axis
KPR#:302
Not ready condition won't go away after applying external pressure
KPR#:307
CE Timetables entries cannot be selected seperatly
KPR#:500
CE: Partial Sequence initializes very slowly directly after loading a method
KPR#:536
CEMS configuration editor issue removing the MS part
KPR#:682
CE replenishment will stop sequence
KPR#:881
Number format causes autostart macro error #16289 during CE ChemStation start
KPR#:1015
errors when trying to edit the Capillaries Table and subsequently when trying to create a Mobility report
KPR#:1398
Method and Run Control not displayed correctly after reconfiguring the instrument from G1600 CE to G7100 CE
KPR#:1432
Calibrated compound found as uncalibrated one using library search report
KPR#:9
CE ChemStation: Update calibration level ignores area correction
KPR#:889
Run a sequence with recalibration, only the first ISTD is updated
KPR#:1089
amount is given as zero when it actually could not be calculated
KPR#:1311
Companion: Adding runs to run table is not possible while a sample is running
KPR#:1200
Companion: operator names cannot have spaces; invalid entry error
KPR#:1278
Companion: Adding runs to run table is not possible while a sample is running
KPR#:1403
Sequence and method path cannot be changed from the Configuration Editor
KPR#:1
LC Chemstation allows configuring a GC6890
KPR#:275
G1600A CE: display problem in Configuration Editor
KPR#:1341
XML import does not support Custom Fields
KPR#:1344
Add ability to insert JPG, GIF or BMP graphical file formats in Report Layout.
KPR#:6
Custom Reports General cal.Signals always reports uncalibrated peaks
KPR#:208
Excel area % report based on hparea00.xls not created when no peaks identified
KPR#:261
Relative Retention Time solution does not work for uncalibrated peaks
KPR#:980
Response range from Signal Options not applied to custom reports
KPR#:1242
Cannot resize chromatogram after you have resized it to a little box
KPR#:15
Chemstation Data Analysis Overlay function shows limited signals per window
KPR#:20
Multiplier difference if used in sequence table or calibration settings
KPR#:365
hpistd00.xls fails to produce ISTD report
KPR#:421
DA.M available for "Aquisition only methods" run in a sequence table
KPR#:447
Sequence Summary Reports do not work with Offline DA
KPR#:493
Running with Offline Data Analysis does not allow calibration .
KPR#:494
Signal Overlay toggle buttons work inverse
KPR#:531
error message "Not a range" when opening a data file with very long sample info
KPR#:555
sequence container is not loaded if Blank(s) in the sequence name
KPR#:721
Configured colors set in configuration editor not taken
KPR#:745
Calibration Table: From/To column not correctly updated
KPR#:793
Tic marks of fraction collector disappear after integration
KPR#:846
Autoscale doesn't work in GC Chemstation when loading next file
KPR#:913
data files cannot be loaded when the complete data path exceeds 140 characters
KPR#:972
Offline session freezes running online sequence and processing data
KPR#:1001
Certain chromatograms cannot be displayed in user scale
KPR#:1007
ChemStation explorer content may disappear
KPR#:1032
Additions to compound name do not show / print correctly
KPR#:1039
Data analysis autoscales incorrectly
KPR#:1069
error messages when switching tasks during reprocessing in Data Analysis view
KPR#:1113
Need to use different data analysis method for second signal, 3rd signal, etc
KPR#:1191
Cannot reprocess from Run Time Checklist
KPR#:1249
Chromatogram will rescale when switching between integration and calibration
KPR#:1354
Reprocess a sequence that is still in progress
KPR#:1356
Isoplot for FLD data shows wrong range for EM wavelength
KPR#:1361
impossible to load only one signal from all runs of current sequence and then overlay with runs from another sequence
KPR#:1375
GC sequences including runs from Back Injector cannot be migrated to container format
KPR#:1394
ChemStation hangs up when overlaying many in the chromatogram window
KPR#:1401
GC sequences cannot be reprocessed anymore after migration to container format
KPR#:1436
Keyword: ECM Integration/OpenLab Option
wrong file extension for SSizip after navigating in the dialog for saving to ECM
KPR#:585
ChemStation reports with CyberPrinter limited to 30 characters as file name
KPR#:593
ECM->Save Data As changes default SSIZIP file name
KPR#:744
data review does not update the .acaml file
KPR#:774
CE .ACAML file: measured mobility and corrected area are missing
KPR#:966
ACAML export: inconsistent availability of creation date and modified date
KPR#:968
ChemStation Administration tool cannot be started right after installation
KPR#:1091
upload process to ECM checks for server name in case sensitive way
KPR#:1101
user without corresponding privileges can save report template
KPR#:1102
user without privileges can preview and print reports in Report Layout view
KPR#:1107
incomplete view initialization when unlocking ChemStation
KPR#:1128
User without corresponding privilege is able to edit Run Time Checklist
KPR#:1129
"System out of memory" exception on uploading large sequence containers to ECM
KPR#:1136
ECM Operator in case of data modification during acquisition and forced upload
KPR#:1156
ECM path dropdown box does not support tokens
KPR#:1204
error message when trying to download a sequence container without data from ECM
KPR#:1205
next injection of a sequence does not continue during Change User
KPR#:1207
OpenLAB Intelligence report can't be created for single runs from ChemStation UI
KPR#:1210
Report history displays a wrong amount in case of a Library Search report
KPR#:1211
OpenLAB Option: Difficulties to lock the ChemStation during reprocessing
KPR#:1212
Problems after moving items from ChemStation to a different LCDF path in ECM
KPR#:1215
Column position of the TCC is only exported to .acaml if the columns are tagged
KPR#:1216
The name of the ISTD compound is not exported to .acaml
KPR#:1220
upgrade installation resets the settings in the Administration Tool
KPR#:1235
no automatic "check-in" after deleting a checked-out method
KPR#:1267
Token "Operator" for LCDF path uses full name including special characters
KPR#:1284
ChemStation instrument not responding during upload of large data sets to ECM
KPR#:1301
data is locally cleaned even if stuck in the Queue
KPR#:1306
Full menu is available after Change User without necessary privileges
KPR#:1308
Acquisition only runs do not write instrument and column parameters to ACAML
KPR#:1309
OpenLAB Option: there is no audit trail for deleting items from spooler queue
KPR#:1337
There is no warning message when deleting items from the queue
KPR#:1338
OpenLAB Option: Cleanup doesn't check whether queue is empty before deleting
KPR#:1339
incorrect DA method in ACAML after reviewing runs in offline session during
KPR#:1347
ChemStation OpenLAB Option does not work when using non-standard ports for communication with ECM
KPR#:1362
token "operatorname" uses full name including special characters
KPR#:1363
column position is only written into the ACAML file for tagged columns
KPR#:1364
OpenLAB Option: color scheme for status of data related to ECM is missing in B.04.02
KPR#:1378
OpenLAB Option: ECM version in reports created before automatic upload after reprocessing
KPR#:1386
OpenLAB Option: no warning message if manually integrated data have not been uploaded to ECM
KPR#:1406
OpenLAB Option: sequence does not continue during Change User
KPR#:1408
a new version of a sequence is created in ECM any time a single result changes
KPR#:1416
data flagged as related to ECM even if the data was deleted from the spooler queue
KPR#:1422
Sequence progress state may not be updated in data analysis view
KPR#:1427
ACAML result file does not contain all peak performance parameters
KPR#:1428
the module type is incorrect in the ACAML file
KPR#:1434
incorrect sample information in ACAML file after reprocessing if the file did not previously exist
KPR#:1438
OpenLAB Option: automatic upload "after any data modification" does not work reliably when keeping the Integration Events table open
KPR#:1439
ECM Target Path missing in report after running a method with automatic upload to ECM switched off
KPR#:1444
OpenLAB Option: data not marked as modified after changing the method
KPR#:1449
report history may display more peaks than the actual report
KPR#:1452
chromatogram data not included in the ACAML file when a sequence is acquired in "Acquisition only" mode
KPR#:1453
ChemStation .pdf reports not uploaded to ECM with the ChemStation data
KPR#:1456
incorrect injection volume in the .ACAML file when using injector program
KPR#:1458
Easy sequence: multiplier value entered in easy sequence user interface is ignored
KPR#:1424
Displaying method in control module prevents other meth download during seq
KPR#:667
Offline crash requires reboot of PC
KPR#:1184
Methods have to be in single folder
KPR#:1185
6850/6890 logbook does not advise of invalid inj volume overrides from seq table
KPR#:1277
Low Thermal Mass (LTM) logging should be in Seconds and not Minutes
KPR#:1423
Read barcode just before injection and use barcode as sample name in report
KPR#:1425
Sample Info vial range for HeadSpace Sampler is 0 - 999; it should be 1 - 70
KPR#:1430
Maximum oven temp not changed after installing column with higher maximum temp
KPR#:1457
ChemStation displays -1.0 during CTC cycle process pre and post run
KPR#:1459
When look-ahead vial is not found in a sequence using overlap, the currently running sample and sequence will abort
KPR#:1460
parameter mismatch error when using a calibrated method for the 68xx GC with RC.NET driver
KPR#:1372
Selecting RTL Help Contents brings up ChemStation Help not RTL Help
KPR#:549
Help for the Purification Software can not be displayed on Windows Vista
KPR#:1105
Resolution Based on EP,BP,JP and DAB incorrectly explained in Help file
KPR#:1357
Isoabsorbance and 3D plots not available in data acquired with two DADs
KPR#:325
Opening Reprocessing copy opens also C:\WINNT\System32\CMD.exe
KPR#:33
unexpected information box when initializing Dual Loop Sampler
KPR#:59
ChemStation does not launch when two MWD detectors are configured
KPR#:289
Problems with initialising the 1100 instrument when a DAD G1315C is present
KPR#:294
ChemStation startup failure in case of printer name exceeding 92 characters
KPR#:372
CE: macro error in instrument logbook after startup without modules
KPR#:1345
Installed two A/D licences, one instrument appears
KPR#:18
IQ fails after upgrade to B.01.03 if LCMS patches are previously installed.
KPR#:327
Multimode Ion Source Report Will Sometimes Not Print Out
KPR#:377
Retention Time Locking B.01.02 SW will not install on GC Chem B.02.01
KPR#:505
uninstallation of B.02.01 SR1 (upgrade installation from B.xx.xx)
KPR#:554
IQ fails after upgrade of CE/MS ChemStation B.01.03 to B.02.01 SR1
KPR#:565
Upgrade of G2730BA LC/MS Data Analysis only from B.01.01 fails
KPR#:578
duplicate Start Menu entries after upgrade of 2D/3D Data Analysis only
KPR#:582
problems with CE/MS upgrade installations
KPR#:591
GPC software does not work if installed on a path containing a blank
KPR#:702
CE IQ is failing after G2201BA CEMS addon uninstallation
KPR#:806
IQ fails after an upgrade to B.03.01 (LC 3D ChemStation)
KPR#:820
SR2 for B.02.01 does not update Help -> About for Config Editor and IQ tool
KPR#:865
With Chinese ChemStation B.03.01 SR1 IQT fails for G2090BA, G2190BA, and G2730BA
KPR#:899
Chinese ChemStation: IQ fails after upgrade from B.03.01 to B.03.02
KPR#:1004
system files may appear as different in the IQT report
KPR#:1097
Cancelling the installation does not rename the ChemStation backup folder
KPR#:1098
ChemStation SR Entries in Add/Remove Programs after upgrade installation
KPR#:1124
B.04.01SP1 upgrade installation removes icons of add-on products from Start Menu
KPR#:1219
Uninstallation of ChemStation does not detect addons
KPR#:1236
no warning displayed during upgrade installation if add-on software is installed
KPR#:1240
Could not install ChemStation after removing previous ChemStation Installation
KPR#:1269
ChemStation B.04.02 on bundle computers cannot be upgraded to DSP1
KPR#:1381
Installing B.04.02 sometimes corrupts the Add/Remove programs list
KPR#:1404
IQT Report checks content of shutdown.mac
KPR#:1409
after upgrade from ChemStation B.01.03, screen of UV/Vis ChemStation is displayed during startup
KPR#:1431
Upgrade Installation fails after changing the installation path
KPR#:1445
manual integration not displayed when separate zooming is enabled
KPR#:298
Height-Reject is not take in account during manual integration
KPR#:413
Reporting of negative peaks resulting from Area Summing
KPR#:690
Integration events values not saved by edit entire method
KPR#:694
determination of tangent point on the tailing part of the peak
KPR#:821
Integration unable to handle complex chromatogram for area summation
KPR#:981
Reintegrate "all signals" with Int. Events open only applied for one signal
KPR#:1010
Batch.M does not display special area annotation for manually integrated peaks
KPR#:1050
integration results of manually split peaks may differ from results before split
KPR#:1121
riders found using new exponential baseline mode can not be deleted manually
KPR#:1123
timed area reject values ignored by manual integration
KPR#:1252
timed area reject values are ignored by manual integration
KPR#:1369
unsaved manual integration events are lost after viewing the Integration Events Table
KPR#:1417
Chinese ChemStation: ramp table does not adapt to control mode of 6850 GC
KPR#:1232
Agilent ELSD is wrongly available in the list of LC modules that can be configured with RC.NET drivers
KPR#:1385
Keyword: Localization,Japanese
impossible to input Japanese Kanji in Name Pattern field on Preferences dialog
KPR#:962
Japanese ChemStation: VWD Dark Current test fails
KPR#:967
msupdate.exe cannot be executed on Japanese Windows Vista
KPR#:1115
Agilent ELSD is wrongly available in the list of LC modules that can be configured with RC.NET drivers
KPR#:1385
Keyword: Localization,Japanese , Localization,Chinese
Agilent ELSD is wrongly available in the list of LC modules that can be configured with RC.NET drivers
KPR#:1385
DDE Comm Failure when starting 6890 with G1888 HeadSpace
KPR#:557
Sequence logfile does not get continued
KPR#:596
Only 20000 lines are kept in the sequence log
KPR#:803
First run of 7890A always generates error in Logbook: undefined symbol, 41276
KPR#:815
partial acquisition sequence overwrites existing sequence logbook
KPR#:1234
column temperature and pressure not in the logbook when using RC.NET drivers for LC
KPR#:1405
Error "Identifier (MSO_PPwidth) is illegal or variable can't be manipulated"
KPR#:4
Cannot install G1043A NIST Library Search Program on B.01.01 LC/MSD ChemStation
KPR#:103
Data Browser rev. A.01.01 not supported with rev. B.01.01 LC/MSD ChemStation
KPR#:124
G2720BA Bioanalysis SW not available at release of rev B.01.01 LC/MSD ChemStati
KPR#:125
Batch review, no manual integration id smoothing is selected in signal details
KPR#:267
Sample Purity affects integration events settings, sets method change flag
KPR#:310
TIC report displays only one MS parameter when in FIA mode
KPR#:314
.wiff file cannot be opened in Analyst if the method has a Post time set .
KPR#:312
Analyst does not launch automatically if root directory is not default one.
KPR#:313
Analyst conversion log file shows warning that CRC doesn't match
KPR#:319
Get application error in DLLHOST.EXE when setting up for running Multiple FIA
KPR#:14
Easy Access rev. A.03.00 not supported with rev. B.01.01 LC/MSD ChemStation
KPR#:123
Abundance Values missing from Lens Ramps
KPR#:309
Display of Time Delay is incorrect for MS acquisition while SIM on Target Mass.
KPR#:318
G2730BA Standalone DA displays Sample Purity Options dialog.
KPR#:320
ChemStation with CTC sampler hangs up when stopping or aborting a sequence
KPR#:1437
AM/PM in time for entries in Method History, also with 24 hour time format
KPR#:10
Pressure unit is not correct on CE ChemStation method printout
KPR#:23
1050 VWD method printout shows too many digits for the Peak Width setting
KPR#:30
During Edit Entire Method, two dialog boxes come up simultaneously
KPR#:114
Operator can edit instrument parameters of a method
KPR#:598
Major error at line 433 in file X:\Astxdrivers\iq\idd\src\ui\ssl1.c
KPR#:697
Method name does not exist in the current directory
KPR#:868
6850 Workstation Internal SW error occurred when configuring a column in 6890
KPR#:1202
"error occurred during loading method" after rejecting method resolution
KPR#:1343
GC Offline Data Analyisis checks for ALS location when loading method
KPR#:1353
LC and CE: methods created based on RC.NET drivers cannot be loaded in Data Analysis Only ChemStation
KPR#:1390
ChemStation crashes when the Method Information is too long
KPR#:1426
Keyword: Method Scouting Wizard
Method scouting sequence does not start due to missing methods
KPR#:1333
Performance problem if many data files to be shown in Navigation Table
KPR#:719
Navigation table cannot display this date time format 20-03-2007 11:41:22
KPR#:836
A09.03 Peak Purity calculation
KPR#:7
not all decimals displayed for the Volume in printout of Fraction Details
KPR#:453
Purify: Only the study creator and administrators can access a study
KPR#:784
impure peak reported as pure under special conditions
KPR#:977
Uni code problem with scheduler
KPR#:171
Online configuration determines what can be done in the offline session
KPR#:1073
Error when using the macro command startsequence
KPR#:1402
Retention Time Locking: can only use kPa unit
KPR#:1392
RTL: New calculated pressure doesn’t update current 7890A methods
KPR#:1415
spectra options are not printed correctly
KPR#:21
"Seq Line"(Sequence line) value for Calibration samples printed wrong in report
KPR#:53
prefix and counter are not reported in hypersequence printout
KPR#:60
problem with sizing of the chromatogram in a Short Report
KPR#:72
Study Run Summary Report: WPS: Tray description is missing
KPR#:75
Instrument curves printed twice, when set in "Sig. Details" and "inst.curves"
KPR#:81
Report: wrong behaviour in fract.table when injec.prog. longer than runtime
KPR#:82
time stamp issues for "inj. time" and "last changed time" for Rev.A Data
KPR#:116
Time Ranges not applied correctly in short report
KPR#:164
after manual integration and peak splitting RT and area counts double
KPR#:238
"Print all Windows" function is not printing correctly
KPR#:240
report does not only print the column used for a run, but all configured columns
KPR#:250
Chromatogram Output in reports: meaning of "Portrait" and "Landscape"
KPR#:276
print to file: no csv file generated using performance and noise report style
KPR#:281
No report shown after method run
KPR#:283
XLS Performance and Noise Rep. : drift given in mAU/min
KPR#:285
Long FIA runs does not list all the injections in the report.
KPR#:315
No report due to "Quantification out of memory" command line error for FIA run.
KPR#:316
in the method printout two DADs have the same header
KPR#:328
"Use Multiplier and Dilution Factor with ISTDs" displayed in all reports
KPR#:349
Printing problems: black bars on the report
KPR#:373
Batch Report: "justify" for alignment is not taken in report/preview
KPR#:420
Group Summary report missing in CSV reporting
KPR#:449
Batch Report: duplicated results for multiple signals in Cal table
KPR#:450
Wrong unit printed on Delay Calibration Reprot
KPR#:458
The use of the manual injector not reported in method report
KPR#:459
page numbers on diagnostic reports are cut of on print out
KPR#:464
Chromatogram might not printed like defined in Graphics
KPR#:490
number of decimals for Capillary and Nano Pump flow in method printout
KPR#:533
Margins are used differently for the Print out of ChemStation Windows Printing
KPR#:590
Path naming on Standard Reports and Ex. Perf. Report not giving ECM info
KPR#:722
Report Layout: Footer print date earlier than last change date for calibrations
KPR#:748
7683 autosampler appears as 7673 on the ChemStation GLP report & meth print
KPR#:755
Report including Calibration Curves displays usage of height instead of area
KPR#:776
problems with chromatogram time and response axes in customized reports
KPR#:783
time stamp of calibration modification changes , if nothing has been changed
KPR#:788
A report cannot be printed if you have overlaid signals
KPR#:811
7673 AutoSampler is printed instead of HeadSpace for Run Info in ChemStore
KPR#:812
Sequence Summary report does not include peaks that are grouped
KPR#:864
With HP LJ 4250 selection of output orientation does not work
KPR#:895
Not found peaks reported different in different report styles
KPR#:897
additional column "ISTD used" has no header in ISTD report of CE ChemStation
KPR#:942
wrong compound numbering in Extended Performance Report after removing compounds
KPR#:949
Japanese/Chinese CS: garbage characters in .DIF output of sequence summary
KPR#:953
inconsistent results in statistics report
KPR#:996
ChemStation does not report resolution as defined in European Pharmacopoeia
KPR#:1011
6890N Full report displays 7683 ALS incorrectly as 7673
KPR#:1108
ChemStation unable to print to screen; Failure at end of run with Vista SP1
KPR#:1109
problem with page numbering in a long sequence summary report
KPR#:1302
Method last changed Date/Time may not be correct on the report
KPR#:1303
Group sum results are not exported to the result.xml
KPR#:1305
Sequence summary statistics with different methods
KPR#:1324
method changes saved into incorrect method after reprocessing
KPR#:1340
"View Method" does not report sample related custom fields
KPR#:1348
only three signals of the DAD exported when printing to .EMF file
KPR#:1349
Grouped calculations/sums will only work for reports using calibration curves
KPR#:1355
page numbers on the Sequence Summary Report higher than 999 are not displayed correctly
KPR#:1366
it is not possible to print report with chromatograms that have been overlaid from different runs
KPR#:1377
plate number per column missing on Extended Performance report
KPR#:1382
Column labels such as batch in Performance + noise report are not labeled correctly
KPR#:1413
Serial number for TCC cluster cut off in sequence summary report
KPR#:1420
Sample Report is truncating long barcodes to 16 characters
KPR#:1435
acquisition parameters missing in the Method section of the sequence summary report when Unqie Folder Creation is switched off
KPR#:1440
Logbook section of Sequence Summary Report incomplete after stopping the sequence
KPR#:1446
changed sample name is only used during reprocessing, but is not reported during review
KPR#:1448
for GC 68xx with classic drivers, the injection date in the report does not use the date format of the Regional Settings
KPR#:1450
instrument actuals not included in ChemStation GLP report for data acquired with RC.NEt drivers
KPR#:1451
ADC: "Location" field in "Sample Info" goes blank after first method run.
KPR#:293
Headspace instr will fail to start if HeadSpace is used as the injection source
KPR#:841
Printout of Partial Sequence table misses essential information
KPR#:54
The data file name in a sequence summary compound report is limited to 8 charact
KPR#:154
No divisor available for samples in the sequence table
KPR#:241
sample name of a run changed when reprocessing parts of a sequence
KPR#:259
performance problem when many sequences and methods are present
KPR#:274
changing a plate in hypersequence table during leads to an error message
KPR#:300
Sample amount ignored for blank runs when entered from sequence table
KPR#:356
Sequence stops after approximately 1700 runs if "Print to Screen" is selected
KPR#:470
Method Name field blank in sequence table (in Data Analysis)
KPR#:480
Dual injector system, exiting the sequence table always returns to the front
KPR#:761
Change of sample type during sequence acquisition is ignored
KPR#:778
Default hypersequence Def_LC.hyp can be overwritten
KPR#:780
Front injector is not installed but it is still available in the sequence table
KPR#:813
Must restart ChemStation for barcode reader availability change (7890A)
KPR#:816
Sequence stops if vial number is 0 on an 1100/1200 system without error message
KPR#:823
Filldown wizard for CTC Increment Directions mixes up row/column directions
KPR#:927
Problems running more than 422 sequence lines with CTC sampler
KPR#:938
Online session closes when copy/paste is used to build seq table
KPR#:941
Sample location not displayed correctly in Data Analysis with high plate number
KPR#:973
Unspecified error after reprocessing a GC sequence
KPR#:1229
Cannot edit Method in Offline session while it is running in an online sequence
KPR#:1246
Method changes not used after pause/edit/save/resume seq using folder ON
KPR#:1247
Browse is missing in sequence table to select method with Unique Folder Off
KPR#:1276
Mismatch for sequence completed time stamp in sequence and instrument logbook
KPR#:1317
sporadic ChemStation crashes after aborting a sequence
KPR#:1322
Online ChemStation may hang when opening Sequence table during acquisition
KPR#:1346
wrong data path after stopping a sequence twice
KPR#:1350
sequence logbook overwritten during partial sequence acquisition
KPR#:1371
7890 Inserting a priority sample into a running sequence using overlapped methods may result in different sample being injected than reported
KPR#:1396
data is acquired into an existing sequence container after canceling partial sequence acquisition
KPR#:1407
warning message at the end of a Purify Study
KPR#:1410
Purify: error message at the end of study
KPR#:1414
ChemStation crashes when trying to use a method containing an ' in the name in the sequence table
KPR#:1441
an error may occur when stopping a sequence immeadiately after start
KPR#:1442
ChemStation crash when trying to open Partial Sequence with non-exisiting data path in the Preferences
KPR#:1443
partial reprocessing takes very long for long sequences even when reprocessing a small part of the sequence
KPR#:1447
Overlapped injections omits run when using the same vials for front and back inj
KPR#:808
Apex spectra not correctly reported
KPR#:920
unexpected question whether user wants to save spectra library with the method
KPR#:1036
sample information of spectra library not automatically extracted from data file
KPR#:1195
Issues with scaling of online plot for DAD G4212A
KPR#:1323
sample information of the data file not automatically extracted when creating a spectra library entry
KPR#:1368
Fraction collection module error message given at different Fraction Collector
KPR#:13
Signal Task: Time reference lines only visible with 256 colors on Compaq bundle
KPR#:44
Operator field in the Change access level dialog box retains only 29 characters
KPR#:62
instrument remains in running status after a diagnose test
KPR#:68
Fraction time table entries corrected by the biggest delay time
KPR#:69
"EMPV Cleaning Procedure" displays misleading status
KPR#:74
Inconsistent update of peak detectors table in Set Up Fraction Collector
KPR#:76
Fraction Preview: Shifted marker in Preview
KPR#:95
Datafile name in File information not updated for overlayed datafiles
KPR#:121
Hardware related zooming issue
KPR#:126
Using "Print window" is not clear what is the active window to print
KPR#:232
Minimize Logbook option is not available
KPR#:234
"switch off pump and lamp" question is coming even if alreay switched off
KPR#:239
Switching between OQ/PV to Data Anaylsis view impact the fraction table GUI
KPR#:286
in online plot it is difficult to differentiate between two DAD detectors
KPR#:322
MultiMode Source is not listed as a possible detector for the OQ/PV
KPR#:446
Recovery Mode not updated in Instrument Actuals GUI
KPR#:455
Incorrect status message of Chip Cube in case of lost synchronization
KPR#:462
Manual injector use is not present in User Interface
KPR#:466
Sample info desciption for OQPV Fraction Collector tests contains symbols
KPR#:486
System.NullReferenceException error may occur in ChemStation
KPR#:496
toolbars can only be configured when displayed in separate window
KPR#:501
option to create folders from Preferences/Paths only available in Windows 2000
KPR#:517
wrong error message: pressure sensor not connected
KPR#:693
pressure signal plot for the PrepPump is missing in Online Plot
KPR#:723
Pump timetable of the PrepPump not giving Solvents for selection in the display
KPR#:724
Error Fetching CP Variable observed sometimes when starting the chemstation
KPR#:731
Splitless Mode - GC displays 'Not Ready" - Chemstation displays "Ready"
KPR#:809
Function keys not displayed on screen
KPR#:1045
Initial Screen Window Size is not kept
KPR#:1046
7890A - Agilent GC Status doesn't show selected.
KPR#:1070
ChemStation hangs when user enters a command while busy indicator is on
KPR#:1096
network datapath not available in ChemStation Explorer after network outage
KPR#:1125
HeadSpace software error box is not shown until the HeadSpace SW has the focus
KPR#:1194
ChemStation displays -1.0 during CTC cycle process pre and post run
KPR#:1230
it is no longer possible to have both a directory and a subdirectory in the Data Paths settings
KPR#:1294
ChemStation uses mixture of color settings from Windows and Configuration Editor
KPR#:1319
signal description in the online plot does not provide wavelength information
KPR#:1336
Verification view does not initialize properly
KPR#:1342
not possible to move Edit Integration Events dialog
KPR#:1376
method change flag is too small in the new UI for LC ChemStation
KPR#:1379
wording mismatch between menu and dialog for saving sequence templates
KPR#:1380
Hyperseq continues running between multiple sequences for one plate after stop
KPR#:77
B.01.01 and PC Anywhere is giving conflict
KPR#:199
Excel workbook issue with "special links" and chemstation.xls reports
KPR#:209
wrong pressure description using Japanese fonts
KPR#:246
Would like to be able to view LC/MS fraction and spectra in same View
KPR#:247
XML Import: Import of LimsId fails if sample amount has been set in import XML f
KPR#:264
EMF files exported from ChemStation to Powerpoint are oversized
KPR#:270
no annotation or move annotation in 3D overlay window possible
KPR#:389
OQ/PV test Injector Precision test show pass instead of failed
KPR#:477
Holmium test passed although hardware fails
KPR#:484
Cap. Pump Flow Sensor Calibration required pump switched on
KPR#:488
Setup window for modules grey out after performing OQPV tests
KPR#:489
not possible to open a Purify study when the Purify Data Base Path is set to C:\
KPR#:541
Verification: unit for RID noise values
KPR#:588
Extracted Chromatograph changes when setting Bandwitdh and exporting
KPR#:589
1100 Diagnosis: Draw action performs red message
KPR#:594
K Prime may not be calculated using void volume
KPR#:602
zoomed peaks may be printed incompletely on reports
KPR#:605
Annotation Menu disables some of the Graphic, Signal options
KPR#:648
Wrong compressibility setting in ChemStation when using Handheld Controler
KPR#:673
Use of external contacts board on 1367C injector no binary output possible
KPR#:675
Invalid fraction start location
KPR#:678
Print report to XLS file strange characters are present
KPR#:679
Purify: sample description only once by wizard
KPR#:680
Started sequence with wrong vial position after changing trays
KPR#:681
zooming reset when copying to clipboard
KPR#:720
No > 10 is not accepted as vial number for Diagnosis single step tests for AFC
KPR#:737
Excel Seqence summary macro is failing
KPR#:791
Prep-Pumps online plot signals need to set again after changing views
KPR#:854
cannot load batch method, if method (on another drive) is specified
KPR#:884
ChemStation crash during MS data AIA export to network drive
KPR#:958
English Acrobat Reader install package on ChemStation CD 2 not working
KPR#:1012
link to the base reference file IQTREF.XML on IQT Report not working
KPR#:1118
Modified or corrupt base reference file IQTRef.xml causes crash of IQT Report
KPR#:1134
with missing base reference file IQTXref.xml the IQT is still reported as passed
KPR#:1135
Chinese/Japanese ChemStation: cannot import .csv file to sequence
KPR#:1233
IQT Report may fail after switching to Diagnosis with invalid files
KPR#:1263
Library search verification test will fail if CE ChemStation is installed onto a drive other than C:\
KPR#:1391
compound custom fields are only exported to result.xml when the compound was found
KPR#:1419
the result.xml file does not contain information about the module name
KPR#:1433
software verification tests may fail when using RC.NET drivers for an LC instrument
KPR#:1454
during verification test FLDARPC.VAL a message comes up the method needs to be migrated to new spectra tools
KPR#:1455
The Extended Parameters for the native sequence table and Easy Sequence Setup (7890A) enable BCR section when that hardware does not exist. This behavior is benign.Temporary Solution:
n/aFix Information:
n/a
1046 FLD cannot be set up from the GUI. If you click the corresponding item in the System Diagram, the following red error message will be displayed: view.floatingmenu "menu[1]."FLD1046" failed. Menu table contains incorrect menu rows.Temporary Solution:
Use the corresponding entry in the Instrument menu to configure the 1046 FLD.Fix Information:
No fix is currently intended.
Running LC Sequences in operator mode it is possible to change signal parameter for various LC detectors. Multiple changes during acquisition are possible and the change will be documented on the Report. A change history list is missing.Temporary Solution:
The change will be documented by the Chemstation using the method changed flag/ time stamp and by the sequence logbook (method changed).Fix Information:
n/a
For ChemStaiton A.10.x revsion following issue has been reported for systems using a stack including 2 times a MWD: The graphical user interface control for the secound MWD in the configuration is controlling the settings of the first MWD of the configuration. This issue only applies fo the graphical user interface. The Instrument menu allows to control the VWD in the correct way.Temporary Solution:
Use the instrument menu to control two MWDs in one 1100 stack.Fix Information:
n/a
For a Micro Wellplate Sampler, the "Fast Reconditioning" option should not be available in normal mode. Under the following conditions, "Fast Reconditioning" gets nevertheless enabled. In the method "Injection Overlapping" is not enabled for the Micro Wellplate Sampler. If "Fast Reconditioning" and "Solvent Custom Calibration" get enabled in micro mode and afterwards the WPS is switched to normal mode, the "Fast Recondition" option is accessible in normal mode.Temporary Solution:
n/aFix Information:
n/a
If a flow of 0.00 ul/min is applied to run a sequence on a system with capillary pump with stop time of e.g. 1 minute, the acquisition of detector signals stops correctly after 1 minute, but data acquisition will nevertheless only complete after 3 hours.Temporary Solution:
Use flows larger than 0.00 ul/min.Fix Information:
n/a
Using the EMF functionality of the Rev. B.01.01 ChemStation the EMF indicators for the needle movements on DLA is not functioning. The Needle movements have exceeded limits and the limit fields are red in Diagnosis View. The EMF icon is green in Method and Run Control.Temporary Solution:
n/aFix Information:
There is no fix planned for this problem.
Following issue has been reported, using ChemStation A.10.0x and higher: Using flow gradients during Fraction Collection results in wrong times for the collected fractions in the Report (in the fraction table). However, tickmarks are displayed and generated correctly, so there is a mismatch betqween tickmarks and the reported fraction table times.Temporary Solution:
n/aFix Information:
n/a
In order to run DAD tests (e.g. DAD Wavelenght test) the DAD has to be switched on. However, the icon for the DAD always is green and ready for test, even when the DAD is switched off.Temporary Solution:
Check the status of the DAD at the instrument itself.Fix Information:
There is no fix planned for this problem.
The pressure and Leak test in G1361A prep. Pump will not finish, unless the Press. is released manually by the user, by opening a capillary. Background: The EMPV valve is not allowed to switch, unless there is low pressure (safety feature).Temporary Solution:
Please manually release the pressure at the end of the test by opening a capillary.Fix Information:
No fix is planned for this issue.
Following issue can be seen in ChemStation B.01.03 using methods with flow composition. Modifying and saving flow composition values are not correctly updated in the "Instrument Actuals" of the corresponding pump, when a new method or default method with different settings is loaded.Temporary Solution:
Either close and reopen the instrument actuals or use the "LC Parameter" view in the method and run control to monitor these values.Fix Information:
n/a
Using the G1321A FLD detector following problem has been reported using ChemStation B.01.01x: Changing from a standard flow cell to a cuvette (e.g. to perform OQ), the system will respond on the report with a "micro flow cell".Temporary Solution:
n/aFix Information:
n/a
Using B.01.03 LC/MS system with the G13315C Detector, methods using FIA will see following behaviour: Running x injections in one FIA run, the system will send y start pulses, so the the report might describe additional runs. For the each injection, two start pulses are sended. Problem will be resolved with the next G1315C firmware revision.Temporary Solution:
The issue will be fixed in the next firmware revision. As a current workaround a macor solution can be used, please contact your Agilent Representative.Fix Information:
n/a
Using the control module G1323B to define the column compensition in the timetable and defined "off" for the temperature. the system will show -274 when opening the colum comp. parameter using the ChemStation.Temporary Solution:
n/aFix Information:
n/a
Using ChemStation please note that the DAD Calibration history is read out of the ldadhistory information in the PCS section of the ChemStation. Attaching a different DAD detector to an existing ChemStation will result in a loss of the DAD calibration history.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
Using ChemStation Rev. B follwing issue has been seen using the same detector type multiple times: In diagostic, the system will list only one detectora for one type.Temporary Solution:
In oder to perfom test, please run the test with only one detector of the same type configured at time.Fix Information:
n/a
Following issue has been seen running ChemStation B.02.01 using Fraction Collection: Defining a sequence and specify in the sequence table column Frac. start column the otion of next plate or next location for the first line, the system will give a warning when starting the sequence that that position is not available.Temporary Solution:
The first sequence line need to have a specific Fraction Start location placed or it has to be left blank, so the system is taking the next free location known by the Fraction collector isself.Fix Information:
No fix is planned for this problem.
Using ChemStation B.02.01 performing verious diagnostis tests using the G1314C VWD detector, the test results are not present in the results file.Temporary Solution:
n/aFix Information:
n/a
Following issue has been seen using ChemStation B.02.10 using fast compensition change/reconditiong option: Rebooting the system and entering the part Fast Composition Change / Reconditioning the first time, the dialog is disabled though the pump is running in micro mode.Temporary Solution:
Please enter and edit/cancel any other dialog (e.g. setup or auxiliary) first, then the options will be available.Fix Information:
n/a
Following issue is seen on ChemStation B.02.01 running Fraction Collectors with Vial plates configured: Defining the position 1 and 101 for fraction collection on a Vial plate, and define the option "next plate" in the Frac. Start column of a sequence the field is ignored without error message.Temporary Solution:
The Next Plate function is a valide functions for Well Plates, not for vial trays. Please use the option "next location" in the Frac. Start column in the sequence table.Fix Information:
n/a
Following issue has been seen running ChemStation B.02.01 and execute the OQ/PV Noise and Temperature Stability using a customized method: Decreasing the stoptime to e.g. to 1 min. the ASTM Noise, Wander and Drift getting not calculated, but the system reports that the instrument verification test passes.Temporary Solution:
The test summary will show the test Noise, Wander and Drift as not passed.Fix Information:
No fix is planned for this problem.
Following issue has been reported using ChemStaiton B.02.01 performing some HPLC System Test. If running system tests, e.g. the HPLC Chip System Test of a Chip Cube system is aborted while running, an error is displayed in the command line: "Fatal System Error: Check system resoureces..."Temporary Solution:
n/aFix Information:
n/a
In some cases the micro pressure test failed whith a leak rate over the upper limit. This result was strongly affected by the volume in the flow path and the evaluation of the test, which was not done after the pressurization of the solvent.Temporary Solution:
The micro pressure test was optimized with a longer pressurization time and the evaluation of the test is done at 8 minutes instead of 4.5 minutes. In addition the test runs with water on channel A1 instead of IPA on channel A2. These are the only changes done for the micro pressure test. The procedure to run the test, the evaluation and the limits are identical to the previous one.Fix Information:
The issue is fixed with ChemStation B.02.01
Following behaviour has been reported for ChemStation using Thermostatted Column compartment (TCC) and the column ID Tag. The number of Injections, present in the column ID Tag is not updated in the following particular case: TCC with column switching valve: In the TCC set up, the user can determin which colum is going to be used, colum 1 - left hand, colum 2 - right hand. If you inject and you use column 1(left) the counter is updated for injection, if the Tag is present, because only the tag for the corresponding site is written to. Placing the tag on the right site, but injecting on the left site, the counter does not increase, because the injection update information is going to be sent only to the left site. TCC without column switching valve: The system is only increasing the number for the left site, not for the right site. For a TCC without a switching valve it should not matter where to place the column ID tag.Temporary Solution:
n/aFix Information:
n/a
Following problem has been reported: Running an ECD detector on LC ChemStation, the online plot scaling is x10 larger than the scale in the data file.Temporary Solution:
n/aFix Information:
n/a
During the calibration process for the RID, the flow cell is purged. Afterwards the calibration sample (Succrose) is injected into the flow cell. Then the calibration is started and the measured value is displayed. If not correct, the correct value of 521000 has to be entered. In ChemStation B.04.01 this value will not accepted. Instead a message comes up specifying a wrong limit of values to be entered.Temporary Solution:
Enter the calibration value via command line with command "NRIU 512000", or send the command via Instant Pilot.Fix Information:
n/a
If you stop a sequence while a run is processed where "Off" is selected for the AutoBalance column, the Autobalance settings will remain inaccessible for the detector.Temporary Solution:
Either restart the ChemStation or complete another run on the ChemStation.Fix Information:
n/a
The Method Overview box shows wrong values for the TCC temperature if the column thermostat is set to the value "as Detector cell". In this case, the Method Overview does not show the real temperature, but instead the inactive value from the most upper field of the Column Thermostat setup dialog.Temporary Solution:
n/aFix Information:
n/a
Select Instrument -> Columns. In the Edit Column Identification Modules dialog you can enter the max. pressure in bar. Only values up to 400 bar are excepted, even if the 1200 LC hardware allows a maximum pressure of 600 mbar.Temporary Solution:
n/aFix Information:
n/a
The following problem is observed with regard to Fraction Collector setup when the Working Mode is set to "Off": All values for "Up Slope", "Down Slope", and "Threshold" are not saved upon closing the setup dialog.Temporary Solution:
n/aFix Information:
n/a
If a blank scan and a sample scan are set up for the VWD G1314D/E are set up in the VWD's timetable, there will be no warning if there is a spectral range mismatch between the blank scan and the sample run. When running the method, the blank scan will be recorded, but not the sample scan.Temporary Solution:
n/aFix Information:
n/a
It is impossible to specify an attenuation of 4000 for the Analog Output of the VWD G1314D/E. In the corresponding dialog, the value 4000 is accepted, but it will not be kept.Temporary Solution:
n/aFix Information:
n/a
For the Multiple Wavelength Detectors G1365C and G1365D, the Wavelength Summary Report is not being shown in the in the Final ChemStation Compliance Report. No Spectrum or Results tables are shown.Temporary Solution:
n/aFix Information:
It is currently not planned to fix this problem.
With an RID in the 1100/1200 system, solvent recycling can be switched. In this case, nevertheless the bottle filling of the pump decreases. If the options to prevent the next analysis or to shut down the pump are enabled, the analysis will stop although the solvent is recycled.Temporary Solution:
n/aFix Information:
There is currently no fix planned for this problem.
If G1316A or G1316B column compartment is part of a cluster with G1316C column compartments, it is not available in Diagnosis view.Temporary Solution:
Perform diagnosis on the column compartment while it is not part of a cluster.Fix Information:
n/a
In the sampler GUI for the CTC the actual injection volume is not correctly displayed. Instead, always an injection volume of 10 ul will be indicated.Temporary Solution:
n/aFix Information:
n/a
For the CTC sampler, the GUI does not display the correct plate/tray after changing the plate.Temporary Solution:
n/aFix Information:
n/a
For a preparative pump, the solvent cannot be selected in the Set Up Gradient dialog.Temporary Solution:
n/aFix Information:
n/a
For LC ChemStation, it is possible to enter the void volume in the Edit Columns dialog. The value can be entered in ml, min, or %. In B.04.02, it is not possible to enter the unit.Temporary Solution:
n/aFix Information:
This problem is fixed in Hotfix 1 for revision B.04.02.
The following problem only occurs with ChemStation rev. B.04.02 and B.04.02 Driver Service Pack 1 with or without Hotfix 1 in combination with RC.NET drivers. The use of classic drivers is not affected. When choosing a data rate (via the corresponding value for the Peak Width in the detector setup) for the detector in LC, LC/MS, and CE ChemStation which exhibits more than one digit after the decimal separator, the selected data rate is not correctly applied, but truncated after the first decimal place. As a consequence, the time axis of the chromatogram will be stretched by the percentage of the deviation in the data rate. This may cause differences in the time axis for different signals in the data. Quantifications based on comparison against internal or external calibration samples as well as internal area ratios are not affected by this defect.Temporary Solution:
n/aFix Information:
The defect is fixed in revision B.04.02 Driver Service Pack 2. Please note that applying the fix may change retention time, area, and height values of the peaks for RC.Net drivers only. Calibrated methods need to be recalibrated in this case.
With classic drivers, the signal description for the RID is "RID1 A, Refractive Index Signal". With RC.NET drivers, the signal description for the RID is "RI1 A, Refractive Index Signal". This difference in the signal description will prevent the peak identification for calibrated methods that have been migrated from classic drivers to RC.NET drivers.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 DSP2.
The position of the column switching valve of a Column Thermostat G1316X (X = A, B, or C) is incorrectly displayed in the Instrument Actuals.Temporary Solution:
Point patches are available for the following revisions: B.04.01 SP1 B.04.02 Hotfix 1 Please contact your Agilent representative.Fix Information:
This defect will be fixed in revision B.04.02 DSP2.
The following defct affects all G1316C TCC clusters: Injection counters for non tagged columns are incremented for all waste-, bypass-, and storage methods. It affects all columns where the columns are marked as "installed" in the ChemStation column table. As a result, the injection counter reports larger numbers compared to the injection performed on a certain column.Temporary Solution:
n/aFix Information:
This defect planned to be fixed in ChemStation B.04.02 SP1.
When using overlapped injection with an ALS, the valve does not switch to the by-pass position on the last injection of the sequence table.Temporary Solution:
Add a blank run with the same method at the end of the sequence to ensure that the valve switches to the by-pass position for the last sample run.Fix Information:
n/a
In case an injector program of a method is longer than the run time, a run with a method cannot be stopped or aborted during the time needed for the injector porgram.Temporary Solution:
The run/sequence can be stopped or aborted after completion of the injector program.Fix Information:
n/a
When using the RC.NEt drivers for LC ChemStation, the progress bar not updated during post-conditioning. The progress bar is only updated when post-Conditioning has completed.Temporary Solution:
n/aFix Information:
n/a
When the data rate of 10 Hz is used, the Real Time Plot display of the chromatogram elapsed time is doubled. When the data rate is changed to the default of 5 Hertz, the Real time Plot window was normal, displaying the same times.Temporary Solution:
n/aFix Information:
n/a
On the 6850 (with no hand held controller (HHC)) it is not possible (very difficult) for a user to activate the "Prep run" function. It should be possible to turn the "Prep Run" function ON from the Chemstation user interface. Customers without the HHC can not turn the "Prep Run" function ON. The HHC must be used. This functionality is important for customers using non-Agilent samplers (P&T, etc.)Temporary Solution:
n/aFix Information:
n/a
The ChemStation would open with an Error Dialog Box titled: 6890 Workstation Internal Software Error Windows XP was set to auto update, when it did the Microsoft Hotfixes, one of them changed the decimal separator from a decimal point to a comma. The Fix: Change the comma back to a decimal point in Regional Settings, and it works as advertised.Temporary Solution:
n/aFix Information:
The Fix: Change the comma back to a decimal point in Regional Settings, and it works as advertised.
When exiting the OFFLINE ChemStation with the view/instrument diagram actived, there's a graphical crash message that appears before closing.Temporary Solution:
n/aFix Information:
n/a
The "Air" and "Makeup" Actuals are missing from the 6890 FPD Detectors screen in Edit Parameters.Temporary Solution:
The correct flows can be viewed from the GC front panel and also “Instrument Actuals”. The FPD functions correctly.Fix Information:
n/a
From Control panel\Regional settings: change the decimal separator from a period to a comma. It is not possible to open a 6890/6850 ChemStation.Temporary Solution:
1. Backup data, methods, sequences, column databases (found in C:\Chem32\DRIVERS), etc Record GC IP addresses 2. Delete IQ1.CFG located under the Chem32\1 directory for example 3. Uninstall Chemstation 4. Reinstall ChemstationFix Information:
n/a
In the 6890 RC.NET driver, changed the GC configuration to have the back inlet go to the back column to the back detector. This change was not reflected in the instrument diagram as it is still showing the back inlet going to the front column to the back detector.Temporary Solution:
The workaround is to turn off and on the instrument diagram to reflect the new configuration changes.Fix Information:
n/a
In the 6890 RC.NET driver, changed the GC configuration to have the back inlet go to the back column to the back detector. This change was not reflected in the instrument diagram as it is still showing the back inlet going to the front column to the back detector.Temporary Solution:
After the configuration change is made to the columns, the workaround is to shut down the ChemStation software and restart to reflect the new configuration changes. Classic 68xx driver works correctly.Fix Information:
n/a
6890N with no tray or autoinjectors installed. Select Injection Source/Location. GC Injector Front/Back/ and Dual is invalidly displayed as an injection source.Temporary Solution:
n/aFix Information:
n/a
Setup method with 2 valves (1 and 2) with initial position to OFF and valve switching to on at 0.01 minutes. First time it runs the timing appears OK. The second time it runs the valves are initialized to ON (a method change ). The valve is checked or set to ‘on’ in the software (OFF on the 7890A). If you try to run the method, the software asks you to save the method, because it has changed in this manor. This occurs with Manual injection only (Press start at 7890A). This does not occur when using an ALS to start the run.Temporary Solution:
The following workaround in now available beginning in B.03.02: Start the run from Chemstation by going to RunControl > Run Method, then press start on the 7890A.Fix Information:
Fixed in 7890A Firmware A.01.10.
7890 with ALS. Create an ALS error, such as a Vial not found event. Instead of offering a pop-up that offers a second chance to Retry/Abort with the named error, this simply aborts the sequence. The error is buried deep in the sequence log of that instrument: 'Method Method started: (F) line# 2 at 2 inj# 1 09:11:51 09/20/07 67 41e0 46f27198 0 Method Instrument running sample Vial 2 (front) 09:11:52 09/20/07 0 1da5 46f271b2 300 GC 1 There was no bottle in the gripper. 09:12:18 09/20/07 0 1da6 46f271b2 0 Instrument GCI1 did not start a run 09:12:18 09/20/07 67 41e0 46f271b2 0 Method Instrument Error - Method/Sequence stopped 09:12:18 09/20/07 67 41e0 46f271b2 0 Method Method aborted 09:12:18 09/20/07 43e 41df 46f271b2 0 Sequence FRONTALS.S terminated due to an error 09:12:18 09/20/07'Temporary Solution:
n/aFix Information:
n/a
Sometimes the software shuts down for no reason. A reboot then shows sometimes the “autostart macro failed, Error -999”. After some more tries the Chemstation starts without any problem.Temporary Solution:
Reinstallation of the Chemstation has fixed this problem.Fix Information:
n/a
Manual injection. Started the run from the 7890A keyboard start button. The method modification status indicates that the method has changed when it has not and the report will indicate 'modified after loading'.Temporary Solution:
Start the run first by going to RunControl > Run Method and then press start at the 7890A.Fix Information:
n/a
7890A with injectors In Data Analysis, load a signal from this GC and Specify 'Full' Report. Print Report. The Module section does not recognize or print any ALS module types or Firmware for it.Temporary Solution:
n/aFix Information:
n/a
On a 7890 GC without 100 vial tray it is nevertheless possible to input vial locations that aren't available when using the filldown wizard of the sequence table.Temporary Solution:
n/aFix Information:
n/a
When running an isothermal GC run, if the oven temp hold time is set to 0.0, signal data will not be acquired. A data file is generated but does not contain the .ch file. When this data file is opened in data analysis, the message no signal data is displayed.Temporary Solution:
Enter a hold time greater than 0.0 in the hold time field will resolve this problem.Fix Information:
n/a
It is not possible to disable method resolution for columns and valves with the 7890A.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1 with Software Driver Version: 3.01.
Sequence aborts in the middle of the run, 7890A lost connection. In the instrument log, it states that the AgGC7890Drv already has ownership; request denied. In the Chemstation software status view, in some cases the GC will come back in Monitor mode.Temporary Solution:
n/aFix Information:
This defect is fixed beginning in 7890A Firmware revision A.01.09. Lab Monitor & Diagnostic SW must be used to update the 7890A firmware. If the old 'Ohana' Utility is used, this problem will not be solved even in firmware A.01.09. This old utility does not update the 7890A firmware properly.
HeadSpace information is not provided in the GLP + Details Report for the 7890A.Temporary Solution:
Headspace information is available when printing the method.Fix Information:
This problem is fixed in revision B.04.02 SP1.
Even though the 7890A Keyboard is set to off, it is not possible to edit instrument parameters such as the oven temperature from the GC Keyboard.Temporary Solution:
The 7890A keyboard display is not displaying the keyboard locked state correctly. By default, the 7890A keyboard is set to ON by the software but the GC keyboard is displaying the keyboard lock as off. Workaround: From the software 7890A GC Configuration, go to the Misc tab. Verify that the keyboard lock is set to off (unchecked) and select OK. It is now possible to edit 7890A parameters from the keyboard.Fix Information:
n/a
The thermal inlet shutdown is not reported in the software “Agilent GC Status” screen. Only the first event, which is 'not ready', is reported to the Agilent GC Status screen. The second event, which is the shutdown, is not displayed.Temporary Solution:
n/aFix Information:
n/a
The vial number is not shown in the sequence screen. Only a "#" sign is shown.Temporary Solution:
n/aFix Information:
Fixed in 7890A Firmware Rev A.01.10 with A.01.02 ALS.
Occassionly, when trying to start a run or sequence on a GC whose front display and ALS are Ready, fails to start. Logbook shows: 'Runs cannot be started until the GC and injector are idle'. This can occur after an abort or stop of sequence, or connecting to a GC that is controlled by another PC.Temporary Solution:
Pressing "stop" on the GC front panel enabled the GC to makes runs again. Power cycling the GC may be necessary.Fix Information:
n/a
7693A ALS errors, e.g. turret, plunger, door open, etc. show a non-specific logbook entry: GCI1 did not start a run.Temporary Solution:
n/aFix Information:
n/a
Parameter Mismatch in the Signal Descriptions between Detector Parameter and Calibration data after upgrading to B.04.01. See attached screen shot.Temporary Solution:
After the upgrade, set the signals to None, save the method and add the signals. Another workaround could be to add the space manually to the calibration signal description.Fix Information:
ChemStation GCI drivers which were delivered prior to B.04.01 composed an incorrect Signal Description (the space was missing). Beginning with B.04.01, there is a space.
Loaded method and method resolution screen is shown. Selected 'Don't Resolve' button. The following message is shown in the instrument log: Method not downloaded to the device because the settings are not compatible with the device. Save the method. Start a run. The following message is shown in the instrument log: Method not downloaded to the device because the settings are not compatible with the device and GCI1 did not start a run.Temporary Solution:
Print the method that will not run or view the 7890A method parameters from the software. Go to Instrument > Agilent 7890A Configuration and correct the Configuration to match the method. 99% of the time it is a Column difference.Fix Information:
n/a
An ALS error occurs on a 7693A with a 7890A. These errors stop the sequence and log to the 7890A status window, but no dialog box with the error is presented. The user would not know what happened if that 7890A status window were not open.Temporary Solution:
n/aFix Information:
n/a
The system includes a 7890A with 2 inlets, single detector and a single tower. When moving the tower from the front position to the back position and again to the front, with correct front method loaded results in method resolution.Temporary Solution:
Workaround: load the method and when meth resolution user interface is shown, select don’t resolve. Then go to the GC Config and change the GC Config to match the just loaded method.Fix Information:
n/a
7890A with ALS. If an ALS error, occurs such as a Vial not found event, there is no dialog box option presented to Retry/Abort. The sequence simply aborts. The error is shown in the sequence log of that instrument: 'Method Method started: (F) line# 2 at 2 inj# 1 09:11:51 09/20/07 67 41e0 46f27198 0 Method Instrument running sample Vial 2 (front) 09:11:52 09/20/07 0 1da5 46f271b2 300 GC 1 There was no bottle in the gripper. 09:12:18 09/20/07 0 1da6 46f271b2 0 Instrument GCI1 did not start a run 09:12:18 09/20/07 67 41e0 46f271b2 0 Method Instrument Error - Method/Sequence stopped 09:12:18 09/20/07 67 41e0 46f271b2 0 Method Method aborted 09:12:18 09/20/07 43e 41df 46f271b2 0 Sequence FRONTALS.S terminated due to an error 09:12:18 09/20/07' GC goes back to "ready" state instead, and vials remain in the position they were when the injector failed (not returned to tray).Temporary Solution:
n/aFix Information:
n/a
The Sampling Diagram should not be displayed when there is not a tray installed.Temporary Solution:
n/aFix Information:
n/a
LC ChemStation A0903 ignore the Win 2000 time format HH:mm:ss and will put always a PM stamp on the injection time for injections done in the morning onto the report. The rawdata information will show the correct injection time. LC Data spooled to Chemstore will use the right time stamp and will give the correct injection, processing & transfer times.Temporary Solution:
Remove the PM symbol in Start>Settings>Control panel> Regional Options, Time Tab. All injections times for LC runs are correctly shown now without the PM stamp.Fix Information:
n/a
In the Sample Information dialog it is possible to specify the subdirectory of the DATA folder where the data file of a single run is to be saved in. In case the DATA directory contains a file without any extension (like e.g. .txt) the name of this file cannot be used for the subdirectory. An error message "no string 8008" is displayed. This situation might occur e.g. when you ran sequence before with Sequence Summary Report and for the name of the report specified a name without file extension.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
In "Setup MSD Signals" panel, set the comment for Active signals (e.g for signal 1 as "Scan #1a"). On running a method or sequence this label is seen incompletely as the MSD TIC title.Temporary Solution:
n/aFix Information:
n/a
The following problem was discovered in the B.01.03 Agilent Active Splitter software. The characteristics of the problem are that when the user starts up the Agilent Active Splitter using the Active Splitter software, it will sometimes cause the Active Splitter to move about 20 times, then it will stop and not communicate with the program. Other times, the Active Splitter will not move at all when it is started with the software. This problem usually occurs upon start up, although sometimes the Active Splitter will function normally for a while. The Agilent Active Splitter program will often put up error messages like "START Timeout after 15 retries."Temporary Solution:
n/aFix Information:
An updated program is available which fixes this problem. It is described in Service Note G2710-55A.
If you run a method with a name of 40 characters or a sequence with a name of 40 characters, it is not possible to create a snapshot during the run.Temporary Solution:
Use method and sequence names with less than 40 characters if you want to create snapshots.Fix Information:
n/a
When a customer does a six injection FIA series with a Dual Loop Autosampler (DLA) the first two injections are of much lower abundance than the other four. If he does a sequence of six injections with the DLA and no FIA, the injections are all of the same height.Temporary Solution:
n/aFix Information:
n/a
If you run a multisignal acquisition with one Scan and three SIM signals under conditions that create a very low (< 20 msec) Dwell time, then the highest m/z SIM ion will have an much greater response than it should. This creates errroneous, artificial data which could mislead the customer. On the customer methods that were provided to us, she had the MSD Acquisition Peakwidth set to 0.10 and the cycle times for the SIM ions set to 5% each. This resulted in a Dwell time of 1 msec for signal MSD4. Changing the parameters (Peakwidth 0.20, Cycle time 25%) makes this problem go away--the highest m/z ion does not have an artificially high response.Temporary Solution:
n/aFix Information:
n/a
If a main root path (e.g. d:\) is added as a data path on the Paths tab of the Preferences dialog, any acquired data will not be saved to this path even when it is selected in the Sequence Parameters or Sample Information. Any other paths work fine.Temporary Solution:
n/aFix Information:
n/a
The software will automatically lower the oven max temperature when a low temp column is installed. This is to protect the column. The software does not rely on the User to do this to avoid damaging expensive columns. The requested enhancement is to automatically increase the oven maximum to match the higher oven max of the newly installed column. Currently, the user is required to manually update the oven max if it needs to be higher; the oven max is not automatically increased to match the higher temp column. This is true for 68xx and 7890.Temporary Solution:
n/aFix Information:
n/a
The run time checklist was set to Data Acquisition Only. In the sequence parameters, the 'parts of the method to run' was set to 'according to the run time checklist'. Completed the sequence and Data Analysis was also done for each sample.Temporary Solution:
It only works if 'ACQ only' is selected in the seq parameter.Fix Information:
n/a
If in addition to the default data path, additional data paths have been specified in the Preferences one of the additional paths can be selected in the sequence template as data path for acquisition. In case the selected data path is not available when the sequence is started (e.g. network problems in case of a network path), the data will be acquired to the default path without any warning to the user.Temporary Solution:
n/aFix Information:
n/a
In ChemStation B.04.02 (pre-release version) it is sporadically observed that sequences do not continue with the next run.Temporary Solution:
n/aFix Information:
n/a
Creating a report preview or printout from Report Layout view does not trigger an entry in the Report History.Temporary Solution:
n/aFix Information:
It is currently not intended to change this behavior.
When a compound group is deleted by deleting all the compounds in the group, the deletion of the compounds is tracked in the method audit trail, but the removal of the compound group is not tracked.Temporary Solution:
n/aFix Information:
n/a
In case a multi-wavelength calibration table is setup to calculate signals separately, it can happen that a calibrated compound appears in the listing of uncalibrated compounds of a library search report, while it is not listed in the calibrated compounds part.Temporary Solution:
The problem can be avoided either by - not calculating signals separately when using a library search report or - calibrating all signals where a compound actually shows a responseFix Information:
n/a
The interactive calibration level update function of ChemStation does not work for CE calibration tables using corrected areas. The real area is added to the calibration table, instead.Temporary Solution:
Delete the level and use the interactive 'Add level' function. This includes the area correction.Fix Information:
n/a
The ASTM method for biodiesel uses two internal standards in the calibration table, but when you run a sequence with recalibration only the first ISTD gets updated.Temporary Solution:
n/aFix Information:
n/a
In case of e.g. a quadratic calibration curve it may happen that an amount cannot be calculated for the area in a chromatogram (if the area is outside the calibrated area range). In these cases the amount will be reported as zero instead of "-" as an indication that the amount could not be calculated. However, with the default report styles, the report contains a warning "invalid calibration curve".Temporary Solution:
n/aFix Information:
n/a
Running A.10.02 CE ChemStation in serial mode, using external pressure following behavior is seen: 1. without pre or post conditioning the correct high pressure from the main method setting is used 2. As soon as pre or post conditioning is used and a pressure setting is defined in the timetable, that pressure remains during the whole run and the system is not going back to the system pressure. --This problem is intermittend 3. as soon as pre and post conditing are used, the problem is always using the pre condition set pressure and changes only the pressure for the post conditing.Temporary Solution:
Following workaround should be used to avoid this issue: 1. using pre and post condition Please add an additional line in the pre conditioning using exactly the same pressure like it should be applied during the run, even a short time will be enough. By doing so the correct value will be used to run the method and it works as well in the sequence. 2. only post condition Please add an additional line in the post conditioning using exactly the same pressure like it should be applied during the run, even a short time will be enough. By doing so the correct value will be used to run the method and it works as well in the sequence. 3. only pre condition this failure is intermittent, To avoid that intermittent failure, please add an additional line in the p reconditioning using exactly the same pressure like it should be applied during the run, even a short time will be enough.Fix Information:
n/a
Using a CE online chemstation B.01.03. following issue has been reported using the online plot: If a negative current and voltage are set and the "adjust" button in the online plot might be used to adjust the signal, the adjust button has no impact, the y-axis goes not into "negative".Temporary Solution:
Use the "Change" button to select both signals and change manually into the necessary negative value.Fix Information:
n/a
If in the CE online ChemStationan external pressure is applied without connecting an gas supply, a not-ready condition "High pressure" is displayed and is not cleared after the end of the specified time for application of the external pressure. Only loading another method will clear the not-ready state of ChemStation.Temporary Solution:
Load another method to clear the not-ready state of ChemStation.Fix Information:
n/a
Following issue has been seen on CE ChemStations B.01.03 only: Setting up any timetable in CE ChemStation it is possible to write new timetable entries, and it is possible to delete the whole timetable, but it is not possible to select a specific entry and to delete or change the specific event.Temporary Solution:
n/aFix Information:
The issue is fixed in B.02.01. ChemStation.
When you open the Partial Sequence dialog immediately after you loaded a method, the Partial Sequence dialog takes very long to open (up to 2 minutes).Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
Following problem has been reported using CE/MS ChemStation B.02.01 SR1: In the Device Configuration of an CE/MS delete the installed MSD, the 3D DAD will be removed as well.Temporary Solution:
To configure the instrument as a CE only you have to delete the MSD a 2nd time and then to re-add the DAD.Fix Information:
n/a
Following problem has been reported using Capillary Electrophorese ChemStation and using the replenishment functionality: Replenish two vials after the other, the replenishment is executed, but the second vial is not recognized to be placed back after replenishment, so the sequence is stopping, with an message "specify outlet vial". After pressing that message, the system is able to continue.Temporary Solution:
Please inject using the “injection table” and specify an outlet vial in the set up.Fix Information:
n/a
During the start-up of a CE ChemStation a user may face the following error messages: "Method not compatible with instrument! Current method is now not valid! Please load valid method!" followed by an "Autostart Macro failed, error #16289 occured". These error messages are caused by number formates using a comma as a decimal delimiter.Temporary Solution:
Shut down the ChemStation and change the regional settings of the operating system to English (US) and adjust time,date and currency formats to your needs, but keep the number format.Fix Information:
ChemStation requires a number format using a dot as decimal delimiter. There is no design change planned.
The following defect affects ChemSation B.04.02 DSP 1 and DSP2: When trying to open the Capillaries Table (Instrument / Capillaries) the following error occurs: "Parameter 4. The name given was not found". The Capillaries Table cannot be edited. Subsequently, when trying to create a mobiliy report (Report Style = "HPCE Mobility") with data acquired without the capillary being specified, the following error will be observed: "Parameter 3: A value is outside the legal range". The report will not be created.Temporary Solution:
N/AFix Information:
This defect will be fixed in ChemStation B.04.02 SP1. A "CE column table" point patch for rev. B.04.02 DSP2 will be made availabe on http://www.chem.agilent.com/EN-US/SUPPORT/DOWNLOADS/PATCHES/MULTIINSTRUMENTCHEMSTATION/Pages/default.aspx
When a CE ChemStation instrument is reconfigured from G1600 CE to G7100 CE, the Method and Run Control view is not correctly displayed, e.g. the tray is not displayed, incorrent summary status window is displayed, etc.Temporary Solution:
1. Shut down online and offlien session of the CE instrument. 2. Using Windows Explorer, delete the files C:\Chem32\x\config.reg and C:\Chem32\x\conf_off.reg, where x is the number of the ChemStationn instrument.Fix Information:
n/a
It is not possible to add a sample to the run table while there is a sample being run. New samples can only be added after pausing the run table and waiting for the run to complete or after all the runs have completed. The icon to ‘add run’ is grayed out during a sample run.Temporary Solution:
n/aFix Information:
n/a
At the Run table, select an operator whose name has a space. Get the following error: 'Invalid Entry Invalid Subdirectory name: Limit Length to 40 characters and avoid /\:.*<>[]|" 'Temporary Solution:
n/aFix Information:
n/a
It is not possible to add a sample to the run table while there is a sample being run. New samples can only be added after pausing the run table and waiting for the run to complete or after all the runs have completed. The icon to ‘add run’ is grayed out during a sample run.Temporary Solution:
n/aFix Information:
n/a
If you change the path for the sequence and the method in Configuration Editor (Configure - Paths) it is not changed in the software. Going to Load Method or Method Save As the path has not changed. Same with sequence path.Temporary Solution:
Load a method or sequence from the location you want to use. The ChemStation shall use this last location.Fix Information:
No fix is planned for this problem.
In cases where a LC and GC ChemStation are installed on the same workstation, the configuration editor offers all LC and GC instruments to be configured as instrument 1 or 2. If a GC6890 gets configured in an LC ChemStation, the startup of the program fails when trying to locate the DEF_GC method.Temporary Solution:
In the Configuration Editor, remove the GC6890 from the LC ChemStation and add it to the GC instrument instead.Fix Information:
There is no fix planned for this issue.
When a G1600 CE instrument is configured in Configuration Editor with CE module and DAD, the settings for the GPIB addresses are saved and applied correctly. However, when reopening the Configuration Editor, the settings are displayed incorrectly: The DAD is not displayed at all, and the CE module is sj=hown with the GPIB address of the DAD.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
Custom fields are used for ECM, LIMs, Easy Sequence. XML import does not support Custom Fields.Temporary Solution:
n/aFix Information:
n/a
Enhancement request to add support for GIF and JPG import into custom reports.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using the Report Layout in ChemStation B.01.01 to create own report styles: Using the "General" or "General cal.signals" sections these options do not appear to work for uncalibrated peak settings in Method in Report -Specify report options. When set to "Do Not Report" the uncalibrated peaks are always reported.Temporary Solution:
It is possible to create a new section for "Cal.signals" not "General cal.signals" and this will only report the calibrated peaks.Fix Information:
No fix is planned for this problem.
When Custom Reports with Excel are used to report the ChemStation results, the following problem is observed when no peaks are found in the chromatogram: With the Excel template HPAREA00.XLS the report is not printed (containing a message "No peaks found"), but the Excel template gives run-time error 1004 "Unable to set the Weight property of the Border class", instead.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
The Relative Retention Time solution available on the Agilent web site in the FAQ section only works for calibrated peaks.Temporary Solution:
n/aFix Information:
n/a
For report styles based on custom report templats (.frp) the settings for the response ranges in the Signal Options are not applied.Temporary Solution:
n/aFix Information:
n/a
In LC/MSD Data Analysis, in spectral task mode, if you load a MSD signal, you will have a chromatogram displayed in the upper have of the data analysis. If you then put your cursor on the lower right corner of the chromatogram window, and click and drag the window to the upper left, you will have a small box in the upper left corner. At that point you cannot resize the window back to its original diminesion. You put the cursor on the little box and try to click and drag it out, it does not expand. The only solution is to shut down chemstation and delete config.reg and restart chemstation.Temporary Solution:
n/aFix Information:
n/a
With ChemStation system A.09.01 or higher follwing issue has been reported during printing multiple overlayed signals: E.g. six signal overlay will be printed out in 2 different chromatograms when you request a Print Report. The first 4 signals print on the first page, and the second 2 print on a separate chromatogram on the second page.Temporary Solution:
This issue has been seen sporadicly and depends on the used printer driver.Fix Information:
n/a
The following problem has been reported using ChemStation B.01.03 using the multiplier/dilution factor:
Entering a multiplier in sequence with 4 (or more)
decimals the results are calculated depending
on the set up used in the Calibration Settings:
Use Sample data: From Samle Defaults Below
1. Enter multiplier in calibration setting
with a leading number except Zero and 4 digits
- the system is cutting the multiplier to
3 digits e.g. 1.234 value
2. Enter multiplier in calibration setting
with a leading Zero and 4 digits
- the system is using and the and reporting
the X. xxxx value, using all entered digits
The used multiplier/dilution factor is printed on the report.
Temporary Solution:
n/aFix Information:
n/a
The following issue has been reported using ChemStation B.01.0x revision and the implemented custom reports to excel for Internal Standarads: HPISTD00.xls The excel file hpistd00.xls fails to produce ISTD report, because the VBA macro stops fails during execution at: Selection.Borders(xlInsideHorizontal).Weight = xlThin The error message is: Run-Time Error '1004': Unable to set weigth property of the Border classTemporary Solution:
The following line exists twice in the hpistd00.xls Visiul Basic macro: Selection.Borders(xlInsideHorizontal).Weight = xlThin. Workaround is to comment these lines out usingwith a single quote.Fix Information:
n/a
If you run a sequence using methods with "Acquisition only" specified in the Run Time Checklist, a DA.M will nevertheless be saved in each data file.Temporary Solution:
n/aFix Information:
n/a
When switching from doing data processing online to offline, no reports are printed. The user will see a message indicating Summary Report requested but no Data Analysis was scheduled.Temporary Solution:
n/aFix Information:
n/a
If the user is running sequences with the first sample being a calibration sample and they select Offline Data Analysis, the sample type is ignored and all samples are treated as Sample and no recalibration is performed. With standard Data Analysis, the calibration sample gets recalibrated then the samples are run in the normal fashion.Temporary Solution:
n/aFix Information:
n/a
When using the Overlay function of the batch review the toggle buttons for overlaid and separated display work inverse. When pressing the overlay button the signals are displayed separated and vice versa. These buttons are only available in the signal tasks.Temporary Solution:
Click the opposite button to achieve the desired display.Fix Information:
There is currently no fix planned.
The error message "Not a range" is observed in the message line when opening a data file in Data Analysis that contains a very long Sample Info. This happens if in the method currently loaded the option "Sample info on each page" is selected in the report settings. If the Sample Info is very long, the option would not allow to display any chromatogram on a single report page. This causes the error described above.Temporary Solution:
Either use shorter Sample Info or deselect to print the Sample Info on each page.Fix Information:
No fix is planned for this problem.
Following issue have been reported using ChemStation B.02.01 and higher using one or more BLANK characters in a sequence name: If the sequence name containing blanks have been used to create the sequence data container, then the sequence will not load in DataAnalysis. No error message is given.Temporary Solution:
Spaces/Blanks are not allowed for the sequence name if this name is used to build the sequence container. To load the sequence data container, close the Chemstation. Than use the windows explorer to delete the blanks in the sequence and batch file name. Restart the session. The sequence and batch file can be found in the unique data file container.Fix Information:
The ChemStation Manuals starting with B.03.01 will contain the information about allowed used characters for datafiles, subdirectories, sequence data containers.
For ChemStation Rev. B.02.01 SR1 following problem has been reported: In the configuration editor is the option present to configure colors (like backbroung, Ret Time, etc).
Specifying a color and saving the cahnges doesn't effect the ChemStation for the following screen elements :
- Window Title
- Retention Times
- Compound Names
- Annotation
- Frame
- Background , this feature is not used anymore, Background color setting is done using the Windows Operating system features.
Temporary Solution:
n/aFix Information:
n/a
The following problem occurs when different retention time windows have been specified for reference and other peaks: When the calibration table is open in the "Identification Details" mode, you can review the actual retention time windows of each compound. When the retention time of a reference compound its retention time window is not updated correctly in the display. However, correct windows are applied during all the calculations.Temporary Solution:
n/aFix Information:
n/a
Following problem has been seen using ChemStation Rev. B and Fraction collection: Loading a datafile including two signals, eg. 35900 ADC and MWD, the Tick marks of the fraction collector appear in the MWD window. After using the menu function Integration ==> Integrate, the fraction ticks disappear, but will be present in the print out.Temporary Solution:
n/aFix Information:
n/a
Load a sequence or single data file. The scaling is set to full ranges. Select Graphics > signal options and change it to autoscale. This chromatogram is correct, but now click on any other data file in the navigation table with a different method and you see that it still keeps the scaling of the other method after switching to autoscale.Temporary Solution:
n/aFix Information:
n/a
Data files cannot be loaded from the Naviagtion Table. when the complete data path exceeds 140 characters. A red macro error occurs "Could not open file:Temporary Solution:\ ".
The data files can still be loaded via Load Signal from the File menu.Fix Information:
n/a
Offline session freezes when running online sequence and reprocessing data in the navigation table in offline data analysis. The problem occurs: Double click the bottom row for acquiring data in the navigation table in offline data analysis. "Can not open file."message appear. Double click the other row for the acquired data. Offline session freezes.Temporary Solution:
n/aFix Information:
This problem can no longer be reproduced in revision B.04.02 SP1.
Certain GC chromatograms can only be displayed in full scale, autoscale or a zoomed scale. This is very inconvenient in case of blank runs where the fixed user scale is not applied and the scale is zoomed to the highest peak. It makes carry over very visible. After loading the datafile, it is not possible to zoom out or apply any larger user scale to suppress the trace peaks to a flat line. LC data doesn't seem to be affected.Temporary Solution:
Set the multi-signal settings to “overlaid” and the ChemStation will make use of the user settings.Fix Information:
n/a
After sequence reprocessing of legacy 16-bit ChemStation data the content of the ChemStation B.02/B.03 explorer may vanish. This happens if the raw data file is stored under \\chem32\x\data with no further subdirectory. Sequence reprocessing generates a new batch (.B) file which is used as an identifier for a sequence container. As the ChemStation explorer is supposed to list only sequence container names, but not the content, all other folders besides the .B file are hidden. If the legacy data is stored in a sequence specific subdirectory , the .B file gets generated there and the other containers do not get hidden. Other possible problem causes are under investigation.Temporary Solution:
Use the Windows Explorer to inspect the \\chem32\x\data folder for .B files. Create a new subdirectory and move the .B files, data files (.D) and methods (.M) to this new subdirectory, but keep the sequence containers generated by ChemStation B.02.01 or higher.Fix Information:
There is currently no fix planned
In Japanese ChemStation part of compound names like e.g. Roman numbers entered in Calibration Table do not show correctly in graphic's annotation. Instead the same indistinguishable glyph is shown for these various special parts of the compound name. Similarly the printout of the chromatogram as report on paper shows the same defect. This is caused by utilizing special characters of the Japanese font like e.g. encircled numbers or Roman numbers, which are not properly drawn or printed.Temporary Solution:
Roman numbers can be entered and formed by individual ASCII characters 'i', 'V', 'X', 'L', 'C', 'D', 'M' like e.g. 'IV' instead of distinct two-byte UNICODE character combining it into one character.Fix Information:
There is currently no plan to fix this problem.
Data analysis will either open in full scale or the correct scale depending on the setting of the MULTI CHROMATOGRAM settings, even when there is only one signal. GRAPHICS then SIGNAL OPTIONS, select Multi Chromatogram “Separated” and “Each in Full Scale” overrides the time range selection even with only one chromatogram.Temporary Solution:
n/aFix Information:
n/a
If you switch between tasks in Data Analysis view during sequence reprocessing, the following error messages are observed in the message line: "Job file not found" and "Couldn't end job".Temporary Solution:
n/aFix Information:
n/a
GCs have more than one signal and customers often split their analysis to more than one detector, typically the second signal. Customers need to be able to specify a different data analysis method for the second, third, or forth signal. GCs do support up to 4 signals. For Dual injection and also for single sampler injections.Temporary Solution:
n/aFix Information:
n/a
When reprocessing from the Data Analysis view in the offline chemstation, ALL items in the runtime checklist are ignored, except the Data Analysis and corresponding Analysis Method for Second Signal. This causes a problem if using macros to send data to LIMS, etc.Temporary Solution:
n/aFix Information:
n/a
Chromatographic Display In data analyis, when switching between integration and calibration the chromatogram will rescale. This can be a real headache. If you have the scaling set up to work with the calibration table (tabbing through target compounds), it would be very convenient to enter into the integration mode and fix and integration without “finding” your peaks again.Temporary Solution:
n/aFix Information:
n/a
It is not possible to reprocess data while the sequence is still in progress.Temporary Solution:
n/aFix Information:
n/a
IsoPlot of FLD data shows wrong range for EM-wavelength. While it is about the expected sprad of wavelength, a wrong descrition for EM-axis (x-axis) by some offset is given (e.g. 12-44nm instead of 668-7000nm).Temporary Solution:
n/aFix Information:
Firmware A.06.11 [005] for the FLD solves this problem.
It is impossible to load only one signal from all runs of current sequence and then overlay with runs from another sequence. It is possible to load e.g. only signal A from each run in the Navigation and then to overlay a signal from a run of a different sequence, however when starting to review the runs via auto-stepping in the Navigation table ChemStation will again load all signals of the runs that originally were in the Navigation Table. A specific signal has to be loaded for each file separately in this workflow scenario.Temporary Solution:
n/aFix Information:
n/a
GC sequences including runs from Back Injector cannot be migrated to container format. An error will be displayed in the Sequence Container Migration dialog during the migration process.Temporary Solution:
A point patch is available for revision B.04.02 Hotfix 1. Please contact your Agilent representative.Fix Information:
This problem is fixed in revision B.04.02 SP1.
When overlaying many runs in the chromatogram window, ChemStation hangs up and has to be terminated via TaskManager. This situation also occurs when adding many runs from a different sequence to be overlaid with the current data, even when the option "always overlay selected datafiles" is not selected.Temporary Solution:
A point patch is available for revisions B.04.01 SP1 and B.04.02. Please contact your Agilent representative.Fix Information:
This problem will be fixed in revision B.04.02 SP1. The fix prevents overlaying more than 15 runs. When adding many runs from a different sequence to be overlaid with the current data set, the user can choose to overlay the first 15 runs with the current run in the chromatogram window or to only add all runs to the Navigation Table.
It was observed that in some cases GC sequences cannot be reprocessed anymore after migration to container format.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
Using easy sequence to create a sequence and entered a multiplier value in the "easy sequence table columns". The Multiplier remained as 0.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
Data, methods, and sequences that are saved in ECM via the ChemStation ECM Integration, are stored as .SSIzip archives. Depending on the type of file, the extension is enhanced, e.g. .m.SSIzip for methods. When the dialog for saving ChemStation files to ECM is opened, a folder is already preselected. If you navigate via the ECM root node to another folder, the extension of the file will be changed to read .m.m.SSizip.Temporary Solution:
Check the file extension in the Save dialog before pressing the Save button. If necessary, delete any wrong additions manually.Fix Information:
n/a
When the CyberPrinter XP is selected as printer in the ChemStation, any report printed to the CyberPrinter is converted to a *.pdf file and placed in the monitored folder and transferred by the print service to the specified location in ECM. During conversion to .pdf, the name supplied by the system is fixed, and defined as • single runs: .pdf • sequence runs:Temporary Solution:_ .pdf The maximum file length for this automatically generated report naming is 30 characters; longer files names are truncated. If, due to the truncation, file names are the same, the files will be saved in ECM as different versions of the same .pdf file.
Make sure the naming scheme for files, sequences, and sequence containers is set up in a way that the limit is not exceeded.Fix Information:
n/a
When using the ECM Save Data As function in the ChemStation the default file name should be the sequence container name, like : Save as Opens in a folder: - Default Name = ChemStation Container name Under following circumstances, this is not the case: Navigating to a folder that contains already SSIZIP files: - Default Name = First SSIZIP file name in Folder Creating a new folder: - Default Name = Becomes emptyTemporary Solution:
Please enter the file name manually.Fix Information:
n/a
The .acaml file of an already acquired sequence is only updated when the sequence is reprocessed. Reviewing the data (e.g. load a data file, change the method, and print a report) does not update the .acaml file.Temporary Solution:
n/aFix Information:
n/a
Although HPCE Mobility report style is selected, the .ACAML file adoes not contain values for measured mobility and corrected area.Temporary Solution:
The values are exported to .ACAML if report style Short is selected.Fix Information:
n/a
.ACAML export does not export sequence creation date. It exports only a "last modified" date and "last modified by" information. Therefore OpenLab Intelligence Reporter can only report the last modified date and user for sequences. On the other hand, the injection data allows to report the acquisition date and user, but does not allow to report the "last modified" date (latest date when results were recalculated). However, it allows to report the "last modified by" user.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
Starting the ChemStation Admin Tool as part of the ECM integration will be launched once. If the installation user tries to start it up again right after the installation, it fails with an error message saying: "Windows cannot access the specified device, path , or file. You may not have the appropriate permission to access the item."Temporary Solution:
In order to access the Admin Tool it is necessary to log off the operating system and log on again.Fix Information:
This issues will be described in the next edition of the installation manual.
Check for server name for upload process to ECM is case sensitive. Therefore, if during logon to ECM at startup of the ChemStation the server name is specified in wrong case, the upload will fail.Temporary Solution:
n/aFix Information:
n/a
ChemStation with OpenLAB Option: A user without corresponding privileges modifies an existing report template. When the user switches to another view, he gets asked whether he wants to save the changes. If he confirms with 'yes', the template gets saved.Temporary Solution:
If a user should not have permission to modify a report template, do not grant him access to the Report Layout View, either.Fix Information:
n/a
In Report Layout View, a user without privileges to print or preview a report, can nevertheless print a report when using the corresponding entry in the File menu.Temporary Solution:
Only grant users access to Report Layout View, who are allowed to print reports.Fix Information:
n/a
When a user unlocks ChemStation, but has insufficient prvileges to access the current ChemStation view, the ChemStation will switch to a view the has appropriate privileges to access. However, this view is not correctly initialized.Temporary Solution:
n/aFix Information:
n/a
User without the privilege to edit a method is nevertheless able to edit Run Time Checklist. However, he can not save the method.Temporary Solution:
n/aFix Information:
n/a
Upload of large sequence containers to ECM fails. The limit is 100 MB of .acaml files being present in the sequence container. The size of these files directly depend on number of injections in the sequence and the number of peaks found in the chromatogram.Temporary Solution:
n/aFix Information:
n/a
As with any currently acquired sequence it is also possible to review the data set that is currently acquired in the Offline ChemStation, when automatic upload to ECM is specified. In this case, when the sequence is completed the user will be informed that the second version of the data set will be uploaded when releasing the sequence container in the Offline session ("forced upload").
For both versions (the one after acquisition and the one from the parallel offline review) the ECM operator is the user who has run the acquisition, even if another user has performed the review in the Offline ChemStation.
Temporary Solution:
n/aFix Information:
There currently no plans to change this behavior.
In Method and Run Control view, a dropdown list is available listing the ten last transfer paths for automatic upload to ECM. When tokens were used to specify the path in the Preferences dialog, the dropdown list will always display the Paths without the tokens, but as the paths were finally used for upload with the final values for the token fields.Temporary Solution:
n/aFix Information:
n/a
When an acquisition sequence is aborted before the first data file was acquired, the sequence container is nevertheless uploaded to ECM. When trying to download such a container without data file to ChemStation again, the following error message is displayed in the ChemStation status line "CP2:Exception in command "NAVbarPrivateSelectDataNode" occured".Temporary Solution:
n/aFix Information:
In revision B.04.02 SP1, the error message will indicate that the data is invalid and cannot be loaded in ChemStation. The data is not downloaded from ECM.
If the ECM user is changed during a sequence (acquisition or reprocessing), during the complete process of user change the next run will not start.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
An OpenLAB Intelligence report cannot be created for single runs directly from the ChemStation UI via the corresponding icon.Temporary Solution:
Create the report in OpenLAB Intelligence Reporter client.Fix Information:
n/a
The report history displays a wrong amount in case of a Library Search report.Temporary Solution:
n/aFix Information:
n/a
During reprocessing (especially with complex reports as e.g. the Performance reports) the menu items and icon for locking the ChemStation are frequently not accessible because ChemStation is busy. The user has to wait for a point of time where ChemStation is not busy.Temporary Solution:
n/aFix Information:
n/a
If a ChemStation master method, sequence template, or data set is downloaded from ECM and afterwards the copy in ECM is moved to a different LCDF path, the local copy in the ChemStation will not be linked to the item in ECM anymore. This will lead to errors during automatic data upload, local method/sequence update from ECM, viewing the ECM Properties, etc.Temporary Solution:
n/aFix Information:
n/a
The column position of a thermostatted column compartment is only exported to the .acaml file if the columns are tagged. Otherwise, the value of the filed in .acaml is “unknown”.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
The name of the ISTD compound(s) is not exported to the .acaml file.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
If a system with B.04.01 ChemStation including G2189BA OpenLAB Option is upgraded to revision B.04.01 SP1, all settings in the Administration Tool are reset to the default values. All configurations have to be repeated afterwards. That may include the transfer settings of each ChemStation instrument in case the Administration Tool allowed configuration separately for each instrument.Temporary Solution:
n/aFix Information:
n/a
When a method is downloaded from ECM and available in ChemStatioon Explorer. In this case it is possible to delete the method from the local disk via the ChemStation File menu. In case the method was currently checked out, it will not be checked in automatically.Temporary Solution:
Check in the method interactively.Fix Information:
n/a
The token "Operator" in the LCDF path uses full name including special characters. Many of these characters cannot be used for LCDF folders in ECM, which results in data not being transfered to ECM.Temporary Solution:
n/aFix Information:
n/a
When large amounts of data are uploaded to ECM via the OpenLAB Option (e.g. the sequence container of a long sequence), the ChemStation will not responding until upload is completed.Temporary Solution:
Do not terminate ChemStation via Task Manager during the upload, but wait until upload has completed.Fix Information:
n/a
There is no confirmation from ECM that the data was successfully transferred before data is removed from the local hard disk (automatic deletion of data enabled).Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1. It will no longer possible to perform the cleanup of the local data as longer as items are still in the queue.
The following problem occurs with ChemStation OpenLAB Option if a user is connected to ECM in the ChemStation who has the permission to enable Full Menu: If a different user who does not have the privilege for Full Menu logs on via Change User, the full menu will still be available to the new user in case the first user had switched it on.Temporary Solution:
n/aFix Information:
n/a
Acquisition only runs do not write instrument and column parameters to the sequence.acaml or sample.acaml file (which are needed for reporting with OpenLAB Intelligence Reporter). The .acaml files are only written when data analysis is performed, too.Temporary Solution:
n/aFix Information:
n/a
There is no audit trail for deleting items from the spooler queue.Temporary Solution:
Only very few administrative users should have the privilege to access the queue. They should be well trained on queue management. Data should be exported, instead of deleted. To export data, select the item in ECM Queue Manager, then select the option “Save the selected item locally”. This will remove the data from the queue and save it to the local disk drive where it can later be reprocessed.Fix Information:
In revision B.04.02 SP1, an audit trail entry will be available in the ECM Audit Trail.
There is no warning message when deleting items from the queue or when saving them to local disk (which means to export the item from the queue to local disk).Temporary Solution:
n/aFix Information:
In revision B.04.02 SP1, the warning message will occur for deletion and export of items from the queue.
Data Cleanup does not check whether queue is empty before deleting. Thus data can be locally removed before a copy is transferred to ECM. If the data is stuck in the queue it may be recovered with the export function of the queue.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
When sequence data is reviewed in the offline ChemStation while the acquisition is still running, under the following conditions a wrong method may be reported for a run in the ACAML file: A sequence line has several injections, and one of the run is reviewed while the other runs of this sequence line are still inprogress. If the review is done with a different method, this method will be reported as the method for all the runs of this sequence line.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
In ChemStation B.04.01, the OpenLAB Option G2189BA does not work when using non-standard ports for communication with ECM.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02.
The "Operator Name" token for the ECM LCDF uses the user's full name. This name can contain any special characters (@, &, ., etc., or local language characters). Many of these characters cannot be used for LCDF folders in ECM, which results in data not being transfered to ECM.Temporary Solution:
n/aFix Information:
n/a
Only for tagged columns, the column position is written into the ACAML file. Otherwise, the value will be "unknown" in the ACAML file.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
ChemStation B.04.01 SP1 provided a color scheme for indicating the modification state of data sets that are related to ECM (green if the data has not been changed locally, yellow if it was changed). In B.04.02 this feature is missing, there is only the yellow indicator that the data is related to ECM.Temporary Solution:
n/aFix Information:
This feature will be available again in revision B.04.02 SP1.
When the Automatic Data Transfer Setting "After Reprocessing" is enabled, a newer version of a repocressed sequence data set is uploaded to ECM. If reports are created during reprocessing, this happens before upload of the newer version of the data set - upload of a newer version will only be done when reprocessing of the complete sequence including data analysis and report creation has completed. Therefore, the report will indicate the ECM version of the sequence data before uploading the newer version. This effect may be most notable when printing the reports to file. In this case the reports indicating the earlier version are uploaded together with the higher version of the data.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1. The report will indicate the ECM version as modified by adding "modified after loading" in brackets.
When a data set is changed by e.g. manual integration, it can be specified to upload a new version of the data by using the option "after any data modification" in the Preferences. However, as long as no report is created a no different sequence data container is loaded, the upload of the new version does not occur. If ChemStation is closed before the upload of the new version, there will be no warning that the changed data have not been uploaded as new version.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
During Change User (for OpenLAB Option), the next injection of a sequence does not start. This happens both during acquisition and reprocessing.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
A new version of a sequence is created in ECM any time a single result changes instead of a single new version for all changes in all runs of the sequence after loading another sequence container in ChemStation.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
When data is to be submitted to the spooler queue for transfer to ECM, the data is flagged as being related to ECM in the ChemStation Explorer. In case the data cannot be uploaded to ECM at this point in time (e.g. because of disconnection from ECM), a copy of the data set is kept in the spooler queue. A user with the corresponding privileges can delete the data from the queue. In this case the data will not be uploaded to ECM. However, the local copy of the data set is still flagged as related to ECM.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
The following problem has been reported for ChemStation revisions B.03.0X and B.04.0X: In rare cases the sequence stays in state "in progress" although it finished properly. The sequence cannot be reprocessed and might even be sent to ECM in this state.Temporary Solution:
To force the status change after the sequence has finished, delete the file acquiring.txt from Windows Explorer. The file is located within the sequence container.Fix Information:
The defect is planned to be fixed in revision B.04.02 SP1.
The ChemStation OpenLAB option offers the option to calculate the peak performance parameters each time a ChemStation report gets generrated. Without having this option selected, ChemStation calculates those numbers on demand only. This is heavily dependant on the ChemStation report style selected (Short, Performance+Noise, Extended Performance report, etc.) If the option is selected, the performance parameters aof a standard perfromance report are calculated and written to teh ACAML result file. However, the noise and extended performance calculation results are not generated.Temporary Solution:
The calculation of all extended performance and noise parameters can be triggered by the following procedure: - turn off the "Always calculate performance parameters" option in the ChemStation Open LAB configuration - add the following Customized Data Analysis Command to the run time checklist of the method in use: macro C:\Chem32\REPSTYLE\shortutl.mac; print USR_CalcPerfNoise$() (Where c:\Chem32 needs to be replaced with the current ChemStation installation path) - select a report style e.g. SHORT, that does not trigger the performance or noise calculation on it's own. This procedure would generate the maximum content of the ACAML result file in respect to peak perfromance parameters.Fix Information:
A defect fix implementation in a Service Pack is considered.
When using RC.NET drivers for LC control, the module type is incorrect in the ACAML file used for Intelligent Reports. Classic LC drivers do not exhibit this problem.Temporary Solution:
n/aFix Information:
n/a
When a sequence was acquired with a ChemStation revision prior to B.04.02 and without G2189BA ChemStation OpenLAB Option [OpenLAB ECM Integration] installed, the ACAML does not exist in the sequence data container [because it is only created when G2189BA is installed]. But the ACAML file can be created by reprocessing the sequence at a later point in time. However, after reprocessing the Sample Information will be incorrect in the ACAML file: For all sequence lines the sample information of the first run will be used.Temporary Solution:
n/aFix Information:
n/a
The option to automatically upload data "after any data modification" is designed to upload data after a new result was generated (method modification and report generation) or manual integration. If the Integration Events Table is not closed before loading the next data file of the same data container, a different single run or a different sequence data container, the changes are not recognized. As a result the trigger to upload the changed data to ECM or to mark the data as "modified after loading" in the report is missing and data will not be uploaded automatically.Temporary Solution:
Manually upload the data set to ECM or close the Integration Events Table after the modifications.Fix Information:
n/a
When first a method is run with automatic upload to ECM after acquisition switched off and then automatic upload is switched on, the ECM Target Path will be missing in the report. The data is correctly uploaded.Temporary Solution:
n/aFix Information:
n/a
The following scenario can occur when autoamtic upload to ECM after "any data modification" is not enabled. When the method is modified, but the data set is not uploaded when switching to the next sequence container, the modified container will not be marked as changed.Temporary Solution:
n/aFix Information:
n/a
In case a report style is selected that only reports calibrated peaks (e.g. Performance Report), the Report History will also display the uncalibrated peaks. This means that more peaks are listed in the Report History than in the actual report.Temporary Solution:
n/aFix Information:
It is not planned to fix this problem.
The chromatogram data not included in the ACAML file when a sequence is acquired in "Acquisition only" mode.Temporary Solution:
n/aFix Information:
n/a
It may happen that ChemStation .pdf reports are not uploaded to ECM together with the data. InsteadTemporary Solution:.PDF.LOCK files are present in this case. This may happen when .pdf reports are open while a new version of the report is to be created or when not all of the .pdf reports are completed at the end of sequence acquisition or reprocessing when the data is to be uploaded.
n/aFix Information:
n/a
When an injector program is used in the method, the injection volume will not be written correctly into the .ACAML file. A negative value will be reported instead of the correct volume.Temporary Solution:
n/aFix Information:
n/a
The handheld control module was used to view and display Method B parameters while running a sequence. The handheld control module was left connected to the 6850 and was displaying the Method B parameters. Leaving the control module displaying the parameters of Method B will cause the sequence to use Method B parameters such as runtime for each line in the sequence. Other methods were not downloaded. The reports however, will have the correct method that was supposed to be used printed on them but the ChemStation used Method B parameters.Temporary Solution:
n/aFix Information:
n/a
After a crash in the Offline part of the chemStation, a reboot of the PC is required to recover.Temporary Solution:
n/aFix Information:
n/a
Customer uses paths like: C:\Chem32\1\methods\customer1 and C:\Chem32\1\methods\customer2, etc. If samples of two or more customers have to be analyzed, it is not possible to use methods from different folders. This has always been the case, but especially commercial labs find this unacceptable.Temporary Solution:
n/aFix Information:
n/a
In the sequence table\Injection volume cell of a 6850 or 6890, enter an injection volume that exceeds the valid range for the installed syringe. This value is ignored and uses the method's injection volume.Temporary Solution:
n/aFix Information:
n/a
LTM reporting should be in seconds and not in minutes as it currently implemented.Temporary Solution:
n/aFix Information:
n/a
It is not possible to add vials to the tray and have the vial bar code read just before injection and recorded as the name of the sample. Reading the vial ahead of time into the sequence table for each vial is time consuming. It is not possible to read the barcode just before injection and have the barcode used as the sample name in the report for 78xx and 6890 RC.Temporary Solution:
n/aFix Information:
Fixed in revision B.04.02 SP1.
HeadSpace software is installed and setup with the G1888 HeadSpace Sampler as the injection source. The vial range is 1 - 70. With the HeadSpace method loaded, select Sample Info\Location combo box the range is shown as 0 - 999; it should be 1 - 70.Temporary Solution:
n/aFix Information:
This problem is fixed in Revision B.04.02 SP1.
In case a column will be installed with a lower max temperature (e.g. 260 degrees) after the usage of a column with a higher oven max temperature (e.g. 300 degrees), the oven temp max is set to 260 degrees which is OK. However, as soon as the column with the higer temp (300 degr.) is installed again the oven temperature maximum remains 260 degrees and will not change to 300 degrees.Temporary Solution:
n/aFix Information:
n/a
During the CTC process cycles of pre and post run, ChemStation Elapsed time is showing -1.0 This is not while the GC is in a run. Set up a CTC run with pre and post run cycle activities. (Prewashes and Postwashes) Run Method. During the pre run before the GC starts, the elapsed time will show -1.0 After the GC run is completed, and the Post run CTC events begin (post washes), the GC elapsed time will show -1.0.Temporary Solution:
n/aFix Information:
n/a
Create a sequence using a method specifying sample overlap. If a non-initial vial is not found, the currently running sample will abort, the sequence will abort, and there will be only an error displayed in the logbook and GC Status.Temporary Solution:
n/aFix Information:
n/a
When acquiring data with a 68xx GC instrument using RC.NET drivers, the signal description of the chromatograms will be "FID1 A, FID1A, Detector". However, when specifying the signal for the Signal Description, the description is "FID1A, Detector". This will lead to parameter mismatch errors when the method is calibrated or saved.Temporary Solution:
n/aFix Information:
This problem is fixed in Hotfix 1 for revision B.04.02.
From the RTLock or RTSearch menus, select RTL Help Contents. ChemStation Help is shown. RTL Help should be shown instead of the ChemStation Help.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
Help for the Purification Software can not be displayed on Windows Vista.Temporary Solution:
Install WinHlp32.exe for Windows Vista.Fix Information:
n/a
Entry in Help for "Resolution Based on EP,BP,JP and DAB" describes 1.18 as formula's factor, where 2.35 / 2 = 1.175 would be correct. The software internally uses 1.175 for its calculation of resolution.Temporary Solution:
n/aFix Information:
n/a
When opening a reprocessing copy of Chemstation A.09.03 (View - Reprocessing copy) it opens also C:\WINNT\System32\CMD.exe. It appears in the toolbar and when opening it, an empty black window appears and cannot be edited. Chemstation sessions are not effected, the cmd.exe window can be closed. When closing the reprosessing session, also the cmd.exe window dissappears.Temporary Solution:
Either open the Offline Version of the ChemStation via Start>Programs>ChemStation>offline version or close the cmd.exe window. For revision B.01.01 the cmd window needs to be closed manually. Regarding CFR 21 part 11security: The CMD window will be only displayed. The user (even adminsitrator) cannot type or execute commands in the window. So there is no violation of CFR 21 part 11 securtiy.Fix Information:
n/a
When a Dual Loop Sampler was powercycled, after initialization an info box is displayed "The tray configuration has been changed! Please check locations used in method and injector program", although the tray configuration in fact was not changed.Temporary Solution:
Click OK in the information box and ignore the warning.Fix Information:
n/a
When two MWD detectors are configured in an 1100 instrument, the ChemStation session will not start. The error message "Autostart Macro failed, error #16289 occured" is displayed.Temporary Solution:
Remove one of the MWD detectors from your instrument and restart the ChemStation session.Fix Information:
No fix is planned for this issue.
In 1100 systems containing the Diode Array Detector G1315C the following problems are observed if the DAD G1315C is not the LAN connection module: At initialisation of the instrument the error message "1100 DAD detector 1 not found. Check that 1100 DAD 1 is correctly configured" is obtained. A power failure for the DAD is observed in the ChemStation GUI afterwards.Temporary Solution:
Connect the 1100 system to the LAN with the LAN card installed in the DAD G1315C.Fix Information:
n/a
Following issue has been seen using ChemStation B.01.03 : The ChemStation has a printer name limitation of 92 characters. If the name is longer ChemStation might freezes during program start and turn into a non responding status in task manager.Temporary Solution:
n/aFix Information:
n/a
When starting a G7100A CE ChemStation instrument without any modules configured, the instrument logbook will contain a macro error: "Undefined scalar (or scalar function): vtCheckVialTable".Temporary Solution:
n/aFix Information:
n/a
During the installation of ChemStation Rev. A.09.03, A.10.01 and A.10.02 following issue has been reported: Installing Product G2077aa (A/D licence) as instrument 1 and Product G2073aa (A/D control module) as instrument 2, the configuration editor will install and set up instrument one only.Temporary Solution:
The installation needs to be done in two steps: First install G2077a A/D system as instrument one and finish the installation. Then add the second instrument G2073a and finish the installation. Both instruments are available in the configuration editor.Fix Information:
n/a
If the B.01.01 ChemStation for LC/MSD with patches (e.g. Multimode source) is upgraded to B.01.03 the Installation Qualification will fail.Temporary Solution:
Uninstall any LC/MS patches prior to upgrading to B.01.03 ChemStation.Fix Information:
No fix is planned for this problem.
The following problem was reported in the rev. B.01.03 LC/MSD ChemStation with a G1978A Multimode Source attached to the LC/MSD. On pages 45-46 of the Agilent G1978A Multimode Source User's Guide (P/N G1978-90006) the checkout for the "Multiple FIA method for G1978A Interface in Mixed Mode operation" is described. At the end of the procedure, the ChemStation should print out the Multimode Ion Source Report. Due to an error in the macro which generates the Multimode Ion Source Report, the report will sometimes not print out.Temporary Solution:
A patch for rev. B.01.03 has been released that fixes this problem. It is described in Service Note G2710-57.Fix Information:
n/a
The following error is presented when installing Retention Time Locking add-on software B.01.02 on the GC Chemstation: “The ChemStation version that exists on this computer is not compatible with the product being installed. Contact Agilent Sales to obtain the correct ChemStation version.” The Retention Time Locking add-on software B.01.02 will not install on GC ChemStation B.02.01.Temporary Solution:
n/aFix Information:
Install RTL revision B.01.03.
This problem is only related to uninstallation of a B.02.01 SR1 ChemStation that originates from an upgrade installation from any other B.xx.xx revision. For uninstallation via Add/Remove Programs, the ChemStation B.02.01 SR1 CD has to be inserted into the CD-ROM drive. If your ChemStation B.02.01 SR1 is not an upgrade uninstallation, it can be uninstalled without the CD.Temporary Solution:
n/aFix Information:
n/a
When a CE/MS ChemStation B.01.03 is upgraded to B.02.01 SR1, the IQ will fail with the following files marked as changed: sys\agilentlcmsdata.dll sys\chemrtd.exeTemporary Solution:
Uninstall CE/MS ChemStation B.01.03 and install B.02.01 SR1 afterwards.Fix Information:
n/a
During an upgrade installation of G2730BA LC/MS Data Analysis only ChemStation, an error message "An on-line core must be purchased in order to install additional instrument modules." will be observed. The upgrade process will not result in a working ChemStation installation.Temporary Solution:
Back up your ChemStation data, then uninstall ChemStation and perform a clean install of your new ChemStation revision.Fix Information:
n/a
After an upgrade installation of 2D/3D Data Analysis only ChemStation (G2090BA/G2190BA) to B.02.01 SR1 or B.03.01, the start menu entries for the instrument instances, the license editor and the scheduler are available twice - both identical and working.Temporary Solution:
n/aFix Information:
n/a
The following types of problems have been observed when upgrading CE/MS systems to B.02.01 SR1: 1. Installation Verification does not pass. 2. Error messages during the upgrade installation process.Temporary Solution:
Back up your ChemStation data, then uninstall ChemStation and perform a clean install of ChemStation B.02.01 SR1.Fix Information:
n/a
If ChemStation is installed on a path containing blanks, the GPC addon software does not work.Temporary Solution:
The ChemStation (and so the GPC addon software) must be installed on a path that dos not contain blanks.Fix Information:
n/a
The Installation Verification will fail under the following condition: After deinstalling the G2201BA MS ChemStation addon part of a CE/MS ChemStation, the Installation Verification will report missing files.Temporary Solution:
n/aFix Information:
n/a
The IQ fails after an upgrade of an LC 3D ChemStation to revision B.03.01 with several missing files.Temporary Solution:
Backup all user created files (e.g. methods, sequences, result data), uninstall the previous ChemStation revision and then install revision B.03.01.Fix Information:
No fix is planned for this problem.
When Service Release 2 (SR2) is installed on top of ChemStation B.02.01 SR1, the version string in Help/About is updated for the ChemStation instruments. However, for the Configuration Editor and Installation Verification tool the version string is not updated.Temporary Solution:
The improper revision information in the Configuration Editor and the Installation Verification tool does not influence the functionality. The successful completion of the IQT wizard and the end of the SR2 installation proves the correct installation of all components of the SR2.Fix Information:
n/a
ChemStation revision B.03.01 SR1 August Edition was released August 16, 2007. The SR1 is coming with a built-in IQT capacity for its qualification. However, with Chinese ChemStation IQT fails for G2090BA, G2190BA, and G2730BA with missing files. Please note that this problem only occurs with Chinese ChemStation.Temporary Solution:
When qualifying Chinese ChemStation B.03.01 SR1 G2090BA, G2190BA, or G2730BA with IQT, the IQT wizard will report missing files. A service note CHEMSTATION-40 was released documenting the affected files. Please aks your Agilent contact to obtain the service note. To document successful validation of the affected systems, attach the service note and the appropriate attachment .pdf file with the IQT qualification result.Fix Information:
There is no plan to fix this problem for B.03.01 SR1.
For Chinese ChemStation only, the IQ fails after upgrade from revision B.03.01 to B.03.02. One changed file is reported: drivers\rapid\language\altcsrcamoduledrv.chs (Version 32.3.9.0)Temporary Solution:
Delete the file drivers\rapid\language\altcsrcamoduledrv.chs before upgrade.Fix Information:
n/a
If system files are present that differ from the versions listed in the IQT reference files, this difference will be noted in the IQT report. However, the report will denote a "Pass" state. The difference in the system file may most probably be caused by the fact that another application on the ChemStation computer installed a different version of that system file.Temporary Solution:
n/aFix Information:
n/a
The following problem occurs when cancelling upgrade installation to revision B.04.01: When the upgrade installation is cancelled and the installation folder has already been moved to the backup location, this backup folder is renamed to the original ChemStation installation directory on cancellation.Temporary Solution:
Manually rename the backup folder to the original ChemStation installation folder name.Fix Information:
n/a
When ChemStation service releases had been installed on top of a full version B.0x.0x, a separate entry on this service release can be found in Add/Remove Programs of Windows. An upgrade installation to ChemStation B.04.01 or higher can be performed without uninstalling the ChemStation service releases, but it may happen that the entries for them are not removed from the list of Add/Remove Programs during the upgrade installation. If this is the case, do not try to remove them afterwards!Temporary Solution:
In order to avoid remaining entries of outdated service releases, uninstall them before performing the upgrade installation.Fix Information:
No fix for this issue is planned.
An upgrade installation from B.04.01 ChemStation to B.04.01 SP1 can be performed without uninstalling add-on programs. However, during this upgrade installation the complete Agilent ChemStation folder is deleted from the Start Menu including the icons of add-on programs like ChemStore.Temporary Solution:
n/aFix Information:
n/a
When ChemStation is uninstalled, the user will not be informed in the case that add-on programs may be installed, e.g. ChemStore. Uninstallation of ChemStation will not be prevented.Temporary Solution:
Verify the presence of add-on programs before uninstallation of ChemStation. Uninstall add-on programs first (follow the uninstallation instructions of each add-on program).Fix Information:
n/a
For upgrade to ChemStation B.04.01 SP1 any additional ChemStation add-on products must be removed first. Unfortunately no warning is displayed if not all add-on products are already removed. An exception to thisnrule is ChemStore/Security Pack which does not need to be uninstalled.Temporary Solution:
Installed Add-On products for ChemStation can be found in Control Panel under Add or Remove Programs. ADDON-entries in ChemStation.ini file may also hint to not yet uninstalled Add-On products. (The ChemStation.ini file is located in the C:\Windows directory.) Follow the specific instructions of each Add-On product for its deinstallation.Fix Information:
n/a
ChemStation B.04.01 installed. From the Add/Remove Programs Remove ChemStation Tried to install B.04.01 SP1, however it failed with the following error. --------------------------------------------- Agilent ChemStation Setup --------------------------------------------- Failed to rename installation directory C:\Chem32\ to C:Chem32_001. Unknown error (-1) Installation fails and will not continue.Temporary Solution:
Restart the PC.Fix Information:
n/a
Driver Service Pack 1 (DSP1) for ChemStation B.04.02 introduces support the G7100A CE instrument and the 1120 Compact LC. The DSP1 can be installed on top of an existing ChemStation B.04.02. However, on Agilent bundle PCs this upgrade on top of a pre-installed B.04.02 ChemStation will not work. Although at the end of the attempted upgrade a message "Setup completed the upgrade installation" is displayed, the DSP1 files have not been installed. The revision code will still be "Agilent ChemStation B.04.02 [96]". The defect is caused by an entry in the following registry key: HKEY_LOCAL_MACHINE\SOFTWARE\Classes\Installer\Products\1F180CCCAEA42FC4B93468945CDBB67C\SourceList\Media\MediaPackage For a successful installation from the DSP1 DVD, the value of this key has to be "\Install\" which is not the case on the bundle PCs with B.04.02 pre-installed. The defect NOT affect e.g. the following situations: - upgrading a bundle system from any version prior to B.04.02 - upgrading from B.04.02 in case ChemStation B.04.02 was installed from the product DVD - installation of B.04.02 DSP1 on a clean system without prior version of ChemStationTemporary Solution:
Change the registry key to the correct value before upgrading to DSP1.Fix Information:
The process for preparation of the bundle computers will be changed. Bundle computers shipping after this change will not exhibit the defect anymore.
Installing B.04.02 will sometimes corrupt the Add/Remove programs list. See attached. Once corrupted, the user must use the CD to remove the chemstation.Temporary Solution:
n/aFix Information:
n/a
The IQT Report tool checks the content of the shutdown.mac, although shutdown.mac is supposed to be modified by the user according to his instrument configuration.Temporary Solution:
n/aFix Information:
This problem will be solved in revision B.04.02 SP1.
After upgrading from ChemStation for LC, GC, CE, and LC/MS, revision B.01.03 to ChemStation B.04.02, during startup of the ChemStation the screen for the UV/Vis ChemStation will be displayed.Temporary Solution:
This affaects only the screen displayed during startup, functionality is not affected.Fix Information:
Currently no fix is planned.
When using the Back button on the "Ready to install" dialog, the user can afterwards change the installation path even for an upgrade installation. However, changing the path for an upgrade installation will cause the upgrade to fail.Temporary Solution:
n/aFix Information:
n/a
The following problem is observed when "Zoom Separately" is selected in the "Signal Options" dialog when you integrate a data file with several signals: Perform a manual integration not in Signal A, but in one of the following signals. The result is not displayed before you switch the view, e.g. to from Integration Task to Signal Task.Temporary Solution:
Perform manual integration only without separate zoom.Fix Information:
n/a
Using ChemStation B.01.0x following issue has been reported: For manually integrated peaks the area reject is taken into account, but not the height reject.Temporary Solution:
n/aFix Information:
n/a
Negative peaks should integrated using the "Negative Peak Integration" Event. The peaks will then be reported as positive values in the UI and report in order to allow for amount calculation. However, using the "Area Sum" event, there are cases where the baseline is above the chromatogram line. The area is reported to be negative in the UI, but positive in the report.Temporary Solution:
n/aFix Information:
n/a
With the def_gc.m loaded, begin to Edit Entire Method... At Data Analysis, the default events table always seems to be uECD and is grayed out (unchangeable). The integration events for that table are: 500 Slope Sens, .08 Peak width, 1 Area and Height Reject. Save the method to a new name. Select Data Analysis. Load the method and select Integration\Integration Events. Now the Events table drop-down is active and TST Default is loaded for test plot. Int events are 1 Slope Sens, .04 Peak width, 1 Area reject, 1.7 Height Reject. uECD is not even available from the drop-down. If a method is edited and saved from Edit entire method, it should stay that way and not be overwritten.Temporary Solution:
n/aFix Information:
n/a
In the tailing part of a peak, it may occur that the inflection point (needed for the calculation of the tangent peak width) is not correctly determined. The problem results from the algorithm applied to find the inflection point: It is done by the first/second derivate of the peak shape but at the tail of the peak, the derivates of the "noise" on the signal may have about the same value as the tail it self. As the calculation looks for the minimum/maximum value of the second derivative, a wrong point may be identified for the inflection point.Temporary Solution:
n/aFix Information:
n/a
When creating area summation groups, the 'off' time for one group and the 'on' time for the next group must be separated by a minimum of 0.06 minutes. In a complex chromatogram this is a significant loss of data.Temporary Solution:
n/aFix Information:
n/a
When several signals are loaded, displayed separately, and all selected via "all loaded signals" option, the following problem is observed when editing the default integration events of a detector type (e.g. "DAD Default"): Changes in the default integration events are only applied to the signal that was the current signal, when the Integration Events dialog was opened. Only after closing the dialog, the changed events are also applied to the other signals.Temporary Solution:
n/aFix Information:
n/a
The method BATCH.M does not display the special area annotation for manually integrated peaks.Temporary Solution:
n/aFix Information:
n/a
If an integrated peak is split by using the corresponding manual integration event, the results for area and height may differ from the results of the original unsplit peak.Temporary Solution:
n/aFix Information:
n/a
riders found during integration using the new exponential baseline mode can not be deleted manually with the remove peak tool.Temporary Solution:
n/aFix Information:
n/a
A timed integration event for "Area Reject" will be ignored by manual integration. Manual Integration always refers to the initial area reject value. The initial area reject is valid for manually integrated peaks for the complete chromatogram.Temporary Solution:
n/aFix Information:
n/a
When an area reject is specified as a time integration event, this area reject will be ignored by any manual integration event, i.e. a manually integrated peak will still be found if its area is below the area reject value.Temporary Solution:
n/aFix Information:
n/a
Unsaved manual integration events are lost after viewing the Integration Events Table (e.g. in order to inspect the timed events).Temporary Solution:
Save the manual integration events before opening the Integration Events Table.Fix Information:
n/a
It was observed that with a system containing a DAD G1315C and another DAD G1315A or G1315B, the following problem occurs when spectra were acquired with the DAD G1315C: The Isoabsorbance and 3D plots can't be viewed.Temporary Solution:
n/aFix Information:
n/a
When changing the control mode for the ramp table of a 6850 GC, the units being used are not changed according to the current mode.Temporary Solution:
n/aFix Information:
n/a
Japanese Kanji characters cannot be entered into the Name Pattern field of the Preferences dialog. Hiragana (fullwidth) and Katakana (both full and half width) characters can be entered.Temporary Solution:
Use a text editor, e.g. Notepad to create the desired text with Kanji characters and paste it into the Name Pattern field.Fix Information:
n/a
Japanese ChemStation: The VWD Dark Current test fails with error message "No sample data" in step "Performing dark current noise measurement".Temporary Solution:
n/aFix Information:
n/a
Msupdate.exe (version 3.9) cannot be executed on Japanese Windows Vista.Temporary Solution:
Just find a Japanese VISTA and found the return if the PING utility is localized and the key characters identifying the response are not there so that msupdate canüft connect to the client. Put un-localized ping.exe file in \Chem32\MS\Firmware folder. After doing that, the msupdate should work fine.Fix Information:
n/a
For Japanese and Chinese ChemStation, the Agilent ELSD is wrongly available in the list of LC modules that can be configured with RC.NET drivers. When the ELSD is configured with RC.NET driver, instabilities are observed during operation in the ChemStation.Temporary Solution:
Remove the ELSD from the list of modules configured with RC.NET and add the ELSD with generic drivers instead.Fix Information:
This defect is fixed in revision B.04.02 DSP1.
GC ChemStation B 01.03, 6890N HSS control soft A 01.04 controlling G1888A Occasionally, when the 6890 GC with an G1888 HS is started, the following lines appears in the instrument logbook: "Error in Hook LoadMethod : HS_HookLoadMethod DDE Comm Failure: Remote execution of (method|load|C:\CHEM32\4\METHODS\LOADTEST.M\) failed. [Channel 459260] Error 41339 occurred: at line 486 in file Headspace In Command method|load|C:\CHEM32\4\METHODS\LOADTEST.M\ in macro HS_Chat"Temporary Solution:
This problem is due to timing issues between the Chemstation/HS software and the Operating system. Minor changes in the Chemstation and Windows operating system are affecting the (DDE) technology. These types of DDE errors appear to be events associated with starting and shutting down a software application. This error is showing a timing problem and should not be captured in the Instrument logbook but it is. The Agilent Chemstation/HeadSpace SW and Headspace Instrument will operate correctly.Fix Information:
n/a
With rev. B.02.01 SR1 it is occasionally observed that for long ChemStation sequences the sequence logfile is incomplete.Temporary Solution:
n/aFix Information:
n/a
Only 20000 lines are kept in the sequence log. When more lines have to be added, the oldest lines are overwritten.Temporary Solution:
n/aFix Information:
n/a
First run of a 7890A (only), no matter what the injection source, always generates an error in the logbook. This does not happen for subsequenct runs. Printer was configured. 'CP Macro ======================================== 10:17:48 02/21/07 70 41de 45dc629c 0 CP Macro In Command IF in macro HS_HookPrintInstMethod 10:17:48 02/21/07 70 41de 45dc629c 0 CP Macro at line 65 in file C:\CHEM32\HS\G292XAA.MCX 10:17:48 02/21/07 70 41de 45dc629c 0 CP Macro Error 41276 occurred: 10:17:48 02/21/07 70 41de 45dc629c 0 CP Macro Undefined symbol: prInjSrcAndLoc 10:17:48 02/21/07 70 41de 45dc629c 0'Temporary Solution:
n/aFix Information:
n/a
Running a partial acquisition sequence into a folder that already contains sequence data from the same sequence template will overwrite the existing sequence logbook.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
When using LC RC.NET drivers, the column temperature and pressure at start and end of the run are not included in the run.log and sequence.log files.Temporary Solution:
n/aFix Information:
n/a
The time format for entries in Method History is taken from Windows, according to the settings in control Panel, Regional Options, Time. Regarding this settings "AM l" and "PM l" symbol will appear in Method History. The behavoir remains when the 24 hour time format is configured.Temporary Solution:
To get the proper 24 time stamp just delete "PM" "PM symbol" (and AM from "AM symbol") in Regional Options. Then the above mentioned time will be displayed in 24h time format. This applies for Windows 2000 and Windows XP Professional.Fix Information:
No fix planned
The printout of a CE method shows mbar instead of bar for the High Pressure Value.Temporary Solution:
Printout this Known Problem Report and keep it with your method printouts.Fix Information:
This defect is planned to be fixed with ChemStation A.10.01
The method printout for the 1050 VWD shows more significant figures compared to the selection list of the VWD user interface. This does not affect the ability to restore the method using the printed information, since the peakwidth can only be choosen from a selection list.Temporary Solution:
A printout of this Known Problem Report should be stored along with the method printouts. The following table shows the corresponding printed values to the setting in the user interface. It can be used to recreate the method starting from the printout. UI setting method printout ------------------------------------------------------------- 0.013 min 0.013 min 0.026 min 0.027 min 0.053 min 0.053 min 0.13 min 0.133 min 0.27 min 0.266 min 0.53 min 0.532 min 1.06 min 1.064 min 1.60 min 1.596 minFix Information:
No fix planned.
In Method and Run Control, select the Method > Edit Entire Method... menu item. Select all four sections to edit, and go through the dialog boxes clicking OK until you get to the Sample Purity Options dialog box. Move it over and notice that underneath it there is the Signal Details dialog box.Temporary Solution:
n/aFix Information:
n/a
A ChemStation user with Operator permission can edit the instrument parameters of a method. He can not save the method, but he can execute single runs with changed instrument parameters.Temporary Solution:
n/aFix Information:
n/a
Error with chemstation B.01.03 SR1 controlling a GC + HeadSpace. Error occurs when clicking on the inlet button: There is a major error at line 433 in file X:\Astxdrivers\iq\idd\src\ui\ssl1.c.Temporary Solution:
It was discovered that method resolution was disabled by adding the disable6890methres=1 in chemstation.ini. There is an error on the back configuration and using disable6890methres=1 does not allow the flows to be corrected. The error disappeared after deleting disable6890methres=1 from the chemstation.ini. The Inlet flow could now be read properly. This error looks bad but the system works correctly.Fix Information:
n/a
Select the method name in the method drop down list, the following message: ‘The method name does not exist in the current directory”.Temporary Solution:
From Windows Explorer, noticed the method name had a space between the name and the .M, i.e. NAME .M. Removing the space and went to the drop down list in the sequence table, and was able to select the method name and the sequence table worked ok. Or save the method as a new name.Fix Information:
n/a
Installed a A-012 column that was already in the column catalog and is also installed in another GC Inventory# Model Number 652.63131 Agilent 19091A-012 Calibration Information Inventory# 652.63131 0.00 m x 0 um x 0.17 um calibrated Last Calibrated: 1/1/1980 On the columns screen, select Change and Install and select the A-012 column and the following error is shown: 6850 Workstation Internal Software Error A software error has been detected within the 6850 workstation software .... This box is shown again a couple more times after selecting OK. You must select cancel. The GC is a 6890.Temporary Solution:
Workaround: add the A-012 column with a new inventory number and then install it.Fix Information:
n/a
When a method is loaded that requires resolution, the user has the possibility to cancel loading of this missing and return to the previous method. In this case, a macro error is observed "error occurred during loading method", and the previous method is loaded, but is marked as changed.Temporary Solution:
n/aFix Information:
n/a
7890 or 6890 Offline session checks for the ALS location when loading a method or processing a sequence. The dialog box, 'resetting to Manual injection' is diplayed after loading a method with dual injectors to a GC chemstation that only has a back injector or on the same GC but you just removed one of the autosamplers. This should not occur in offline data analysis.Temporary Solution:
n/aFix Information:
n/a
LC and CE methods that have been created based on RC.NET drivers cannot be loaded in Data Analysis Only ChemStation G2190BA. An error message "This method was migrated to the new format and cannot be loaded in a classic instrument configuration." is displayed. This also applies to an CE or LC instrument that has not yet been configured as using classic or RC.NET drivers.Temporary Solution:
n/aFix Information:
n/a
When the user enters a very long text (c. 1200 characters or more) for the Method Information, the ChemStation will crash when leaving the Method Information dialog.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
In cases where the ChemStation preferences "unique folder creation" are turned OFF, no method development sequence created with the Method Scouting Wizard add-on will run successfully. The sequences will stop due to missing methods that cannot be located at the specified path. The "unique folder" data storage is mandatory for method scouting sequences generated by the Agilent Method Scouting Wizard add-on.Temporary Solution:
Turn the "unique folder creation" option ON. This setting is available in the ChemStation preferences menu.Fix Information:
A fix is considered for the next version of Method Scouting Software.
After upgrading from rev. A.09.01 to A.09.03 LC/MSD ChemStation, then go into Data Analysis and select the Peak Purity tool and click on the first peak, the error "Identifier (MSO_PPwidth) is illegal or variable can't be manipulated" can occur. This does not occur with a clean load of rev. A.09.03.Temporary Solution:
n/aFix Information:
n/a
When trying to install G1043A NIST Library Search Program rev. D.01.00 by running setup.exe from the CD root directory, the error "You must install the HP MSD ChemStation Software before installing this Database sofware" is generated. An OK button is displayed, and when it is clicked the installation program stops.Temporary Solution:
n/aFix Information:
A fix is currently being investigated.
The currently shipping G2727AA Data Browser software rev. A.01.01 (Sept 2004) is not supported and does not work with the LC/MSD ChemStation revision B.01.01. A new version of Data Browser software compatible with rev. B.01.01 LC/MSD ChemStation will be available in the future.Temporary Solution:
n/aFix Information:
n/a
At the release of rev. B.01.01 LC/MSD ChemStation software (Sept 2004), the G2720BA Bioanalysis software (Peptide Tools + Deconvolution) is not available. The Peptide Tools functionality is currently not supported with rev. B.01.01 LC/MSD ChemStation, and the Peptide Tools menu item in the Spectra menu in Data Analysis is greyed out. However, the Deconvolution program part of the Bioanalysis software does work and has been tested. For customers upgrading from rev. A.xx.xx LC/MSD ChemStation + G2720AA Bioanalysis software to rev. B.01.01 LC/MSD ChemStation and who wish to continue to use Deconvolution, the G2720AA license number can be entered for the G2720BA product during the ChemStation software installation.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using B.01.01 LC/MS ChemStion only in conjuction with smoothing: The Signal Detail screen for LC-MS allows to select smoothing. If it is selected, then manual integration are not marked on batch review results. The user can do a manual integration and can save it to batch. The first column will get the "s" indicator. If the data file is re-selected, then manual integration is not visible. (the "s" indicator is still in place).Temporary Solution:
The issue only occurs if the user selects 'gausian' smoothing and leaves the default value of '0' in the 'smooth parm' column of signal details. Please enter a non-zero value as a work-around.Fix Information:
n/a
While developing a method containing "sample purity options" the system will change integration events during integration. In addition the method change flag will be set during running a sequence, and that method change flag will be present starting from sample 2 till the end of the sequence. The flag is triggered due to the changes of the integration events.Temporary Solution:
n/aFix Information:
No fix is planned.
When you set a FIA method with two MSD parameters as being variables, in the final report only the first one in the FIA table is displayed.Temporary Solution:
The user can set to have those 2 parameters visible in the report by going to Data Analysis>Graphics>FIA Display Options...Fix Information:
n/a
This happens with G2710 LCMS + Analyst 1.4 MR + the Analyst patch. -Set up a method that has a post time set up in the pump. -Set up the Analyst to do automatic wiff file translation, launch Analyst at the end of the run. Use the naming convention for wiff file same as that of data file.(the default option). -Run this method.Temporary Solution:
n/aFix Information:
n/a
-Install G2710 LCMS and Analyst 1.4MR with Analyst patch . -Launch Analyst and create a new root directory e.g Build Test. -In Analyst/Set Up Current Method menu select options ‘Automatic wiff file translation’ and ‘Automatically Launch Analyst’ and using theTemporary Solution:select the above created root directory. Keep all other options as default. -Run a Method/Sequence At the end of the run, Analyst does not launch automatically and pops up 'translat' dialog box.
n/aFix Information:
n/a
When running a conversion using the ChemStation->WIFF with a .csv file option, the log file shows a warning that the CRC doesn't match.Temporary Solution:
n/aFix Information:
n/a
If you into Run Control/Run Multiple FIA Methods, then select Edit/Group/Add and give it a group name (eg testgroup), then select Edit/Method/Append, intermittent you will get an error: "An application error has occurred... DLLHOST.EXE Exception: access violation: (0xc0000005, Address: 0x10011c5b If you then close ChemStation, you will get an HPCORE error (no other details, no GPF message), then you click okay to that and ChemStaiton window will close. It occurs with WIndows 2000 or WInNTTemporary Solution:
Running Multiple FIA Methods is not supported with rev. B.01.01 LC/MSD ChemStation. It will be supported and the defect fixed in a future revision.Fix Information:
n/a
The currently shipping G2725AA Easy Access software rev. A.03.00 (Sept 2004) is not supported and does not work with the LC/MSD ChemStation revision B.01.01. A new version of Easy Access software compatible with rev. B.01.01 LC/MSD ChemStation will be available in the future.Temporary Solution:
n/aFix Information:
n/a
The abundance values are cut off in the Lens Ramp window from Manual Tune. This makes it impossible to determine the maximum abundance range when ramping a lens element.Temporary Solution:
n/aFix Information:
n/a
If you set a time delay for start of the MS run, then select SIM on Target Masses, then enter a Target Mass, the time delay resets to 0. This is for display purposes only--it actually does start after the delay time but the display says 0.Temporary Solution:
n/aFix Information:
n/a
If you install G2730BA LC/MSD Standalone Data Analysis you will be able to access the Sample Purity Options dialog under the Method menu. However, the MSD options will be grayed out. Since this is a Standalone Data Analysis and the Sample Purity Options are NOT post-acquisition parameters, that dialog should not be available in G2730BA.Temporary Solution:
n/aFix Information:
n/a
When using the "DLW_Priming_Rev01" injector program in a configuration including a CTC sampler, ChemStation will hang up when stopping or aborting a sequence.Temporary Solution:
The "DLW_Priming_Rev01" injector program originates from an earlier version of the CTC control software and has been removed from revision A.01.06 which is required for ChemStation B.04.02. The following workaround is avaialble: - Use the standard DLW injector program (LC-Inj DLW Standard_Rev03.cyx) and perform a blank injection. This injector program is included with the Agilent A.01.06 CTC Control CD. - Since the DLW flushing times are method-dependent, they can use the standard DLW injector program to create a “Priming.M” method that will perform the DLW flushing steps and stator wash. - Because the standard DLW injector program does perform an injection, it can be used with ChemStation sequences and MassHunter worklists.Fix Information:
n/a
A perfomance issue using ChemStation B.02.01 and higher has been reported under the following condition: If many single runs are in one folder, then the ChemStation needs quite some time to fill the Navgation Table with the necessary data.Temporary Solution:
Please split the content of one huge folder containing single runs into smaller directories.Fix Information:
n/a
The Chemstation cannot display the following date time format 20-03-2007 11:41:22 in the Navigation table in Data analysis. The following date is shown when this date time format 20-03-2007 11:41:22 is used in the regional settings: 01-01-0001 00:00:... The date time format shown in the File Information is: 20-03-2007 11:41:22. The report shows the date correct and not this strange date: 01-01-0001 00:00:.... The navigation table can display correctly the following date/time format: 25-Apr-07, 08:30:04Temporary Solution:
Work around: Use the following date time format in the regional settings: 25-Apr-07, 08:30:04Fix Information:
n/a
In Peak Purity Task the Purity Calculation of the peak will change after hitting the option button and leaving the window without changes. The Purity Factor of the Peak will be recalculated and the result can differ.Temporary Solution:
When working with peak purity, Agilent strongly recomments to update to the new spectra/purify options. After a new method is created based on def_lc.m and you are going to use the purify option For the first time, the system will ask you to chose the newer version - select YES. Methods already specified with the older spectra/purity options can be updated by Typing following command into the command line: SPC_NewVersion=1 The system will update to the newer spectra/purify options.Fix Information:
n/a
When the Fraction Details are displayed in Data Analysis, a Print button is available to print these details. On the printout, the decimal places for the Volume are missing, although they displayed in ChemStation.Temporary Solution:
n/aFix Information:
n/a
Only the study creator and members of the Administrators group can access a Purify study.Temporary Solution:
n/aFix Information:
n/a
The results of the peak purity calculations are presented in the report in the following way: 1. The calculated values for the spectra a re presented graphically together with the threshold value. Three values above the threshold indicate an impure peak. 2. Average purity factor and threshold value based on the values that lie above the threshold. A text states whether the purity value is within the threshold. The graphical presentation (1) is based on purity values that are not rounded, while the values described in (2) are rounded to 3 fractional digits. In rare cases it may happen that the average of the purity values that lie above the shreshold is rounded to value equal to the threshold. In this case the graphical representation represents data points above the threshold while the text states that the values are within the limit.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using macros to set up scheduler files. The macro is written in Unicode, but if the scheduler shows the macro, the first line is grayed out. Two extra characters are add ( like Yp).Temporary Solution:
There is an issue regarding the conversion between Unicode and ANSI files. In order to run the macro corret to create the scheduler files, the macro needs to be converted to ANSI. A tool is available on ChemStation "UnidcodeToAnsi.exe" in the Chem32\sys directory. For more information refer to the "Upgrade preperation guide B.01.01" G2170-90222.Fix Information:
n/a
Limited capabilities in offline ChemStation (online configuration determines what can be done in offline session), e.g.: Online: back injector, offline: no way to reprocess front injector sequence (and vice versa) Online: back injector, offline: no way to develop front injector sequence for next acquisition (and vice versa) Online: front injector, offline: no way to edit method with back injector (and vice versa) Also, if hardware is simply plugged into the GC and turned off (Tray) it is considered in the offline session. The Tray must be unplugged as well or it is considered in the configuration.Temporary Solution:
n/aFix Information:
Fixed in Revision B.04.01 SP1 for 7890A only.
E.g. when using the ChemStation Scheduler, you can use the command "startsequence" to start sequence acquisition. When using this command in ChemStation B.04.0x, the following error will occur: Sequence was aborted due to a file access error. Please restart your sequence The sequence will nevertheless start, but the sequence container for the sequence data is not created and the data files are stored directly in the data path/subdirectory. Methods and the sequence file are not copied to the sequence directory.Temporary Solution:
Use the command "runsequence" instead.Fix Information:
This problem will be fixed in revision B.04.02 SP1.
n/aTemporary Solution:
n/aFix Information:
n/a
Following issue can be seen on ChemStation A.10.02 reports, using intervall options within the sequence table:
Running a sequence with follwing setup:
1. line: "Sample type" => "Calibration",
"Cal Level" => "1", "Interval" => "2"
2, 3 and 4. line: "Sample type" => "Sample"
"Datafile" => ""
On the report it is observed that for the first "calibration" Sample, The "Seq Line" field displays "2" instead of "1"
For all samples is showing the correct sequence line..
After samples 2, 3, for the calibration sample (Cyclic calibration)the Seq Line is displayed as "4" instead of 1.
Temporary Solution:
n/aFix Information:
n/a
The following defect is observed in a system with wellplate handler when running a hypersequence using prefix/counter option for the datafile subdirectories: In the hypersequence report the specified values for prefix and counter are not reported.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
Sizing of the chromatogram output for a Short report does not work in the 20 - 40% range for the Response axis. The 40 - 100% range works correctly, values smaller than 20% are not allowed.Temporary Solution:
n/aFix Information:
n/a
For a system with Dual Loop sampler configured to use wellplate the following problem is observed: When a study is run using the Purify software, the Study Run Summary report does not show the tray description for the Dual Loop sampler.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
Following issue has been reported on B.01.01 ChemStation printing a report including the instrument curves: If the Instruments curves has been enabled twice, the Instrument curves will be printed twice on the reprot. It is possible to define the "Instrument Curves" within the "Edit entire methods - Edit instrument curves" , or/and in the "Signal Details" at the 'calibration symbol' in the GUI of the method and Run Control.Temporary Solution:
to print the instrument curves on the report, please select the option only once , either in "edit entire method - instrument curves" or in " signal details" of the 'calibration symbol' in the GUI of the method and Run Control. Once the instrument curves printing option have been set twice, the method will remain these parameters. In order to overcome this issue, the method needs to be rewritten using a method where these option not have been set twice.Fix Information:
n/a
In case a injector program is used it is important to have a run time specified for the method that is long enough to cover the time needed for all steps of the injector program. Otherwise problems like wrong information in the reports and runs not stopping are observed.Temporary Solution:
Be sure that the runtime of the instrument modules is long enough to cover the whole needed to complete the injector program.Fix Information:
There is no fix planned for this problem.
Data, Methods and Sequences taken from a Rev. A.xx.xx ChemStation and reprocessing them on Rev. B.01.01 ChemStation, the ChemStation reports will report different timestamps for "Injection Time" and "last changed" Time for Data Acquisition and Data Analysis method compared to ChemStation Rev. A.xx.xx reports. The Rev. A.xx.xx ChemStation stores times using standard C functionality that stores times as seconds since the 01.01.1970 00:00:00 GMT. When a time (e.g. an injection time) is stored in a data file, GMT is calculated in repect to the standard time zone of the ChemStation: Pacific Standard Time. The Rev. B.01.01 ChemStation is using the regional setting of the Windows system, there for the time stamps are updated to the local time after reprocessing. ChemStation Plus system using the TZ variable will NOT see this issue.Temporary Solution:
Detailed information about the time stamp issues are documented in the Readme.txt file. The Readme.txt file is present in your Chem32\Core directory. Note: ChemStation Plus system using the TZ variable will NOT see this issue.Fix Information:
It is not planned to fix this problem.
Within the Data Analysis of B.01.01 Chemstation following issue has been reported: Defining User Ranges in the "Signal options" the Time Ranges are applied to the chromatogram and displayed/printed accordingly, for Response ranges are not taken into account. The issue can only be seen when in addition the Multi Chromatogramm Scaling is set to "each in full scale".Temporary Solution:
Applying "all the same scale" for the Multi Chromatogramm will fix the issue and the scaling is working correctly.Fix Information:
n/a
Using ChemStation Data Analysis Software following issue has been reported using manual integration. Load a datafile and integrate a peak manually. The RT and the Area (and the name) are written to the peak. Now use the manual "split peak" funktion and the RT and the Area are printed double on the screen as well on the print out. This defect is most pronounced when you split the peak directly at the apex. The impact of this issue decrease with the distance to the apex.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
Following issue has been reported for the Spectra Part of the Data Analysis in ChemStation by using the "print all window" funktion: If a spectra and referecnce is called in on screen the system will either not print all windows or is overlaying them. The issue depends on the print driver in use.Temporary Solution:
n/aFix Information:
n/a
When a TCC of column switching valve and two columns is used, the ChemStation will for each report both columns, and not only the one used for this run.Temporary Solution:
n/aFix Information:
This problem will be fixed with revision B.04.02 DSP2.
Edit the Specify Report section of a method. In the Chromatogram Output, you can select e.g. "Portrait" or "Landscape". It would be expected that "Landscape" means that the chromatogram is printed in landscape format. But actually it means that is printed rotated by 90 degrees in comparison to the orientation of the printer setup. I.e., if you set Landscape in File -> Printer Setup, the chromatograms are printed in Portrait.Temporary Solution:
n/aFix Information:
It is not planned to change this behavior.
Using the "Performance+Noise" report style it is observed that .csv reports are not created when they are selected in the "Specify Report" dialog.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
If in the "Signal Details" dialog of the Data Analysis part of method no detector signals are selected, but only non-detecor signals like pump flow, no report will be created when running this method.Temporary Solution:
There is a macro available in the LC User Contributed Libraries that allows to only save the instrument curves. It is macro #14 on the ChemStation B.02.01 SR1 CD.Fix Information:
No fix planned.
Following issue has been reported printing the "Performance + Noise" report to XLS files: In Excel (sheet "noise") the drift is shown in mAU/min instead of mAU/h.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
For example, in a run of 750 injections, the report lists only 400 flow injections with Inj , InjTime, Location and FIA Sample Name. After the 400th line it just displays a line in bracket as "…(total number of flow injections is 750)" . i.e it does not list the details of remaining 350 flow injections. Note that it does complete the 750 actual flow injections, but in the report it LISTS only 400 flow injections.Temporary Solution:
n/aFix Information:
n/a
If you run a very long FIA run and then request a report or preview, the report is neither generated for preview nor gets printed. Instead it gives a command line error in red "Quantification out of memory".Temporary Solution:
n/aFix Information:
n/a
In a system with a DAD G1315C and an additional DAD G1315A or G1315B the following issue was observed in the method printout: The sections about the detectors both have the header "Agilent 1100 Diode Array Detector 1".Temporary Solution:
n/aFix Information:
n/a
The message about the usage of multiplier and dilution with ISTDs as specified in the Calibration Settings dialog is displayed in all kind of reports, but it should only be displayed in the relevant reports (i.e. ISTD and ISTD%).Temporary Solution:
n/aFix Information:
n/a
Using B.01.03 or higher customers reporting black bars on their print reports, the report on the screen is correct. The problem only happens using 1. single signal 2. zoomed in 3. zoomed in that one peak in the window is cut off, and the peak is huge compared to the others Depening how deep the zoom is, the problem might appear on the report.Temporary Solution:
The problem is printer depended, PCL6 is giving problems. Please use either PLC 5e or the Postscript driver.Fix Information:
n/a
Using the ChemStation batch function, the system gives you the possibility to adjust the batch report by: open th "options for Batch Review", "Report Table" tab, and define the "justify" for each parameter. This alignement is not applied to the preview/report.Temporary Solution:
n/aFix Information:
n/a
If you perform peak grouping, the Group Summary report is missing when the report is printed to .csv file.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
If you setup an calibration table for multiple signals and treat the signals separately, the batch output reports the multiple peaks of the same name, but the reported data (RT and Amount) for each peak are duplicates of the first occurance of that peak. Example Calibration table: # RT Signals Compound Amount Area Respf 1 1.001 DAD1 A Peak1 2.000 200 0.0100 2 1.001 DAD1 B Peak1 2.000 400 0.0050 3 2.001 DAD1 A Peak2 2.000 300 0.0066 4 2.001 DAD1 B Peak2 2.000 350 0.0057 Batch report: the reported RT and Amount for Compound nr 2 and 4 are respectively a duplicate of nr 1 anTemporary Solution:
Temporary Solution Notes: This option is only used in case the user preferres are confirmation result rather than a qualifier ratio. To get the confirmation result calculated in the batch table it's recommended to name the compounds different for each wavelength. (e.g. by adding the wavelength information in brackets). This helps as well to differenciate the results on the batch report.Fix Information:
n/a
Using ChemStation REv. B.02.10 following issue has been seen printing a Delay Calibration Report. The printed report will state the "current delay" in time(sec): xx instead of volume ulTemporary Solution:
n/aFix Information:
No fix is planned for this problem.
Following issue has been seen printing a method using a manual injetor. The method print out does not mention the use of the manual injector.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
Following issue has been reported printing diagnostic reports: The page numbers (page 1 of ***) are cut off on the right side in the printouts. The "total numbers of pages" are not completetly printed.Temporary Solution:
n/aFix Information:
n/a
Following issue has been seen on ChemStation B.02.01 using the option "User Range". Only if the multi-chromatogram layout is select to be "separately", the Time axis is used on the printed report, but not the ranges.Temporary Solution:
‘Each in same scale’ allows comparison of identical graphs and uses the Response Range. If using “Each in full scale’, it ignores the Response range setting and only uses the Time.Fix Information:
n/a
With a Nano Pump (G2226A) or a Capillary Pump (G1376A), only two decimals can be configured for the pump flow. However, the method printout will show a third decimal that is 0.Temporary Solution:
n/aFix Information:
n/a
Following printing problem has been reported using ChemStation Rev. B using the "page set margins" for the manual printout in File: If in data analysis a data file is selected and a "page set margin" is set, the margin is applied printing "all windows", but the bottom page margin is ignored for "print selected window".Temporary Solution:
n/aFix Information:
n/a
Following issue using ChemStation B.02.01 SR 1/SR2 with ECM integration has been reported: Printing a report using the extended Performance Report, as well on Customized Reports, the path information should state ECM as path information.Temporary Solution:
A point patch will be available, please contact your Agilent Representative.Fix Information:
n/a
Following problem has been reported for reports, genenrated with the Report Layout using ChemStation: Performing a sequence, including calibration samples, the time stamp "last changed" time for the Data Analysis method will be 2-3 seconds earlier thant the footer print time stamp.Temporary Solution:
n/aFix Information:
The print handling of the report is a taske, using multi-processes which are getting different time stamps. Therefore when the report is set together, it is possible that the header/footer information get a different timestamp that than the chromatogram/compound section.
The 7683 autosampler is installed on the GC but it shows up as a 7673 on the Chemstation GLP report and when the method is printed.Temporary Solution:
The 7673 is the old family name and covers all of the Autosampler components including the various controllers, multiple different injector modules, and the tray(s).Fix Information:
n/a
If a report style is used that includes calibration curves, in the formula the report indicates the the Y axis represents Height although calculation based on Area has been selected. The values of the parameters itself and all the calculations are correctly based on Area.Temporary Solution:
n/aFix Information:
n/a
The following problem is observed with customized report templates that contain chromatogram in the general section: When defining to have the time axis at the top or the response axis at the right side of the chromatograms the numbers are displayed inside the chromatogram area. Also when having the time axis at the top of the chromatogram, the signal description is displayed at the bottom and is upside down. The retention times are also turned 180 degrees in the latter case.Temporary Solution:
n/aFix Information:
n/a
Following problem regarding the "calibration modified flag" has been reported for ChemStation: As soon as the integration settings are opened again after a method has been saved, the flag of the calibration modification is set.Temporary Solution:
n/aFix Information:
n/a
The dual injector GC gives two data files, one with ADC-1 and AIB-1, and one with ADC-2 and AIB-2. It is not possible to overlay the signals and print them. The following message is given: “A report cannot be printed if you have overlaid signals. Use Load Signals and try again.”Temporary Solution:
After selecting the signals you want to overlay, go to FILE, select PRINT, then select “Selected Window”.Fix Information:
n/a
Information in ChemStore. The HS Sampler and its serial number information are not being displayed. Headspace is shown as a 7673 AutoSampler. Headspace runs correctly and puts the data in the study, but it does not include the G1888. This was found using G2070BA B.02.01 SR2 with ChemStore/Security Pack B.03.03 SR1.Temporary Solution:
n/aFix Information:
n/a
Two peaks are grouped together. The individual reports have the peaks grouped, but the peaks are not grouped in the Sequence Summary Report.Temporary Solution:
n/aFix Information:
It is not planned to fix this issue.
The selection of printout's orientation from ChemStation by File -> Printer Setup does not have the desired effect. Instead the setting determined at the respective printer's perferences (e.g. by Window’s Start -> Settings -> Printers and Faxes) does rule the printers behaviour. If e.g. portrait is selected there than every printout is portrait. This is independent of a landscape orientaion selected in ChemStation by File -> Printer Setup! The opposite (landscape stays landscape in spite of portrait selected in ChemStation) is true, too. This behavior was observed with recent PLC5 or PCL6 printer drivers for HP LJ4250 obtained from www.hp.com.Temporary Solution:
Utilizing the PCL5 printer driver deliverd with ChemStation on CD 2 (User Documentation and Accessories) under \Support\Printers\English\lj4050_pcl5e as lj1130en.exe solves the problem. Installation of that printer driver can be checked from Control Panel -> System -> Device Manager by navigating to the respective communication port used for the LaserJet 4250. The Driver Details show Mirocosoft as Driver Provider, a Driver Date: 7/1/2001 and a Driver Version: 5.1.2600.0Fix Information:
n/a
The way a peak that is not found is reported is different in different report styles. Built in Styles: short: "-" Full: "-" Detail: "-" Performance: "Not found" Report Layout Templates: EXTSTD.FRP: "0" LIBRARY.FRP: "-" AreaPCT.FRP: "0" SIMPLE.FRP: "0"Temporary Solution:
For the Report Layout templates this can easily be changed by editing the templates.Fix Information:
It is not planned to fix this issue.
When ISTD report is created, the report will provide the information which ISTD is used for each reported compound. In CE ChemStation, this value is included in the result table, but it is displayed without the corresponding header.Temporary Solution:
n/aFix Information:
n/a
Compouinds that were once in the calibration table of a method, but have been deleted are still taken into account for numbering in the Extended Performance Report. This is only true for the section of the report that reports the performance parameters for the individual peaks.Temporary Solution:
n/aFix Information:
n/a
When printing the sequence summary report, it is possible to select file output as .dif file. When opening this file with e.g. Microsoft Word, Japanese and Chinese charcters will not be displayed characters.Temporary Solution:
The defect is caused by the fact that the .dif file is stored in ANSI format and thus cannot handle Japanese and Chinese characters. In order to view the content of the .dif file, open it with an application that is able to read ANSI files, e.g. Notepad.Fix Information:
No fix is planned.
The following problem is observed for calibration tables with separate calculation for each signal. If several peaks have the same name, the sequence summary report may calculate the statistics from peaks in different signals and summarize them under the header of the first signal.Temporary Solution:
If peaks with the same retention time in different signal have the same compound name, separate calculation for the signals has to be disabled.Fix Information:
n/a
ChemStation does not report resolution as defined in European Pharmacopoeia. EP requires the following formula to be used: R = 1.18 * (Tr(b)-Tr(a)) / W50(b)+W50(a) Only the following definitions are available in ChemStation for resolution: USP, ASTM (in Extended Performance Report): R = 2 * (Tr(b)-Tr(a)) / WB(b)+WB(a) Half-width method as used in Performance Report: R = (2.35/2) * (Tr(b)-Tr(a)) / W50(b)+W50(a) JP (in Report Layout view only): R = 1.18 * (Tr(b)-Tr(a)) / W50(b)+W50(a)Temporary Solution:
In Report Layout view, use Resolution (JP) which uses the same formula.Fix Information:
n/a
6890N.05.05 with 7683B ALS installed in back position. Load a signal produced on this GC and specified 'Full' report. Print Report. The 7683B ALS is incorrectly interpreted as a 7673 with a Firmware of G1530N.05.05 as follows: ======================================================= Module Type Firmware rev. Serial number --------------------------------------|------|---------------|--------------- 68GC 68GC N.05.05 CN10429002 7673 7673 G1530N.05.05 A 6890A with two 7683A injectors installed prints this as '7683/G2912A.02.01'Temporary Solution:
n/aFix Information:
n/a
Running with no printer configured except Nova pdf and printing to screen. The OS is Vista SP1. At end of run, software hangs with pop-up: 'Due to a printer configuration failure, the ChemStation is unable to print to screen!'Temporary Solution:
n/aFix Information:
n/a
In case of a very long sequence summary report (more than 1000 pages), the page numbers for the included Analysis reports in the Summary section are displayed for any page number higher than 999.Temporary Solution:
n/aFix Information:
n/a
In case a data file is loaded from the Navigation Table together with a method (e.g. option "Use method from data file"), it may be observed in rare cases that a wrong date/time stamp for method "last changed" is displayed on a report created after loading. In such case the date/time stamp is set to the time of the report creation.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
The group results in the normalized percent report are not exported to the result.xml, see attached JPG file. This problem occurs in 7890 or 68xx.Temporary Solution:
n/aFix Information:
n/a
If a sequence includes runs with another method apart from the method that should be used for statistics calculation (e.g. a wash method), the statiscal calculations in the sequence summary report cannot be performed for all the runs. The statistical calculations will be done separately for each section of the sequence between the runs with the second method.Temporary Solution:
Mark the second method as "Acquisition only".Fix Information:
n/a
When modifying a method in Data Analysis view immediately after reprocessing sequence data (i.e. without loading a data file in between manually), the changes are always saved to the master method, even if the sequence method should be loaded according to the settings of the Preferences. The defect only occurs in revision B.04.02 with Unique Folder Creation turned on (without unique folder creation, reprocessing is performed in Method and Run Control view).Temporary Solution:
Before modifying the method after reprocessing, make sure the correct method is loaded. This can be achieved most easily by double-clicking one of the runs in the Navigation Table. In this case the correct method according to the Preferences will be loaded.Fix Information:
This problem is fixed in Hotfix 1 for revision B.04.02.
When reviewing the method parameters for run via "View Method" in Data Analysis view, the sample-related custom fields are not included in the report.Temporary Solution:
n/aFix Information:
n/a
When the file output to .EMF is selected for the report, only three signals of the DAD are exported to .EMF even if more signals are active.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
The grouped calculations/sums will only work for reports using calibration curves. They will not work in area percent mode. Even when working with Chem2XL and try to bring over area percent and compound group information, the group information is not available.Temporary Solution:
n/aFix Information:
n/a
For very long Sequence Summary Reports (> 999 pages), there is a problem with the page numbering. All page numbers above 999 are not displayed correctly, the string ## is printed instead of the page number.Temporary Solution:
n/aFix Information:
This problem will be solved in revision B.04.02 SP1.
It is not possible to print report with chromatograms that have been overlaid from different runs.Temporary Solution:
n/aFix Information:
n/a
In case no column or geometry details for the column (like length and diameter) have been specified by the user, the plate number per column is not calculated in the Extended Performance report.Temporary Solution:
n/aFix Information:
This problem is fixed in Hotfix 1 for revision B.04.02.
In the Performance + noise report, the information in the column descrition is not the same as the info entered in the column database / inventory list. Product should be labelled as Model no. Serial # Inventory # Batch Manufacturer And some LC column related labels / info is printed.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
When the sequence summary report is printed as text file, the serial number of a TCC cluster (which consists of a concatenation of the serial numbers of the individual TCCs) is cut off.Temporary Solution:
n/aFix Information:
n/a
7890A GC with 7693A ALS Sequence table displays and reads valid and lengthy barcodes correctly. However, the report heading is truncating these to 16 characters.Temporary Solution:
n/aFix Information:
n/a
The acquisition parameters missing in the Method section of the sequence summary report when Unqie Folder Creation is switched off. Only the run-time checklist, method information and data analysis parameters are reported.Temporary Solution:
n/aFix Information:
n/a
The logbook section of the Sequence Summary Report is incomplete after stopping the sequence.Temporary Solution:
n/aFix Information:
n/a
When a sample name is changed in the sequence table, this modified sample name is only applied in the reports created during reprocessing. Reports that are printed during review, e.g. by pressing the Print button, will still display the original sample name as specified during acquisition.Temporary Solution:
n/aFix Information:
n/a
For GC 68xx with classic drivers, the Injection Date in the report does not use the date format as specified in the Windows Regional Settings.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
The ChemStation GLP Report or custom reports do not display the instrument actuals at start and stop of the run for data acquired with RC.NET drivers.Temporary Solution:
n/aFix Information:
n/a
Retention Time Locking (RTL) only allows the unit of kPa. It is not possible to use psi or bar.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
The current method pressure is 20 psi and the RTL table has psi as the unit. The new calculation pressure is 18 psi. When clicking “Update current 7890 Method”, the new pressure is not updated to 18 psi. It remains at 20psi.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
In "Method and Run Control" view of A/D online session, "Location" field in "Sample Info" dialog box goes blank after first method run.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
The Headspace instrument will fail to start if HeadSpace is used as the injection source in GC Chemstation B.02.0x. HeadSpace as an "Injection Source" is now available beginning in ChemStation Revision B.02.01. However, the HeadSpace software, G2924AA Rev A.01.04, does not support this new injection source. If HeadSpace is used as the injection source, there is a failure to start the HeadSpace instrument.Temporary Solution:
The workaround is to use the "Manual" choice as the Injection Source (as previously). The G2924AA HeadSpace Revision A.01.05 corrects this issue.Fix Information:
This defect is fixed beginning in G2924AA HeadSpace Software revision A.01.05.
Made up a 3-vial sequence using both ALS injectors and the same vial sequence (1, 2, and 5) for front and back. In this case, the action should be: Run 1: Front: vial 1 Back: no injection Run 2: Front: vial 2 Back: vial 1 Run 3: Front: vial 5 Back: vial 2 Run 4: Front: no injection Back: vial 5 Enabled overlapped injections in the sequence parameters. The result was that the back injection from vial 1 was never made. The following result is shown: Run 1: Front: vial 1 Back: no injection Run 2: Front: vial 2 Back: no injection Run 3: Front: vial 5 Back: vial 2 Run 4: Front: no injection Back: vial 5 Even though vial 1 has not been injected in back a datafile has been created: "001B0101.D".Temporary Solution:
n/aFix Information:
n/a
The partial sequence dialog offers the option to print the run list. This printout does not contain: operator date/time information page number total page number instrument nameTemporary Solution:
There is currently no adequate workaround available.Fix Information:
n/a
With ChemStation Rev. B.01.01 following issue has been reported using Sequence Summary: Using the Sequence Summary, Compound Summary option, the data file name within the resulted report is limited to 8 character.Temporary Solution:
A macro is availabe to fix this issue. Please contact your Agilent support.Fix Information:
n/a
There are only multipliers available in the sequence table (Multiplier and Dilution), but no divisors.Temporary Solution:
If the user wants to divide the results with a constant factor she/he needs to calculate reverse value first and enter that in one of the multipliers.Fix Information:
For this issue currently no fix is planned.
A sequence of several runs has been used to acquire data, and the sample names have been assigned to the runs using the corresponding column in the sequence table. When now the sequence is to be reprocessed, but some lines are deleted from the table, the sample names are applied to different runs than during the acquisition if the data file naming is not mastered by the sequence table.Temporary Solution:
ChemStation provides the function "Partial Sequence" that allows the user to select only parts of a sequence with automatically assigning the original data file names to the runs even when in the original sequence the names are handled in the Sequence Parameter dialog.Fix Information:
It is currently not planned to change this behavior.
If many methods and sequences are present in the corresponding folders of an instrument, the following performance problem is observed: The first time after starting your computer when you load a method or the sequence table of a sequence, it takes a longer time until the corresponding dialog finally will appear.Temporary Solution:
n/aFix Information:
n/a
When a hypersequence is running it is nevertheless possible to change the plate of the currently running seuqence. However, this leads to the following error message at the end of this sequence: "CP_hyper2:Parameter3:A value is outside the legal range".Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
A sequence is reprocessed with the option "Use Sequence Table" checked in the Sequence Parameters dialog. When in the sequence table no vial number is specified (i.e. when the run is actually a blank run), a sample amount specified in the sequence table will not be applied to the run.Temporary Solution:
If you want the sample amount to be applied with this setup, specify any vial number for the run in the sequence table.Fix Information:
n/a
In case a sequence is configured to output all the single run reports to Screen, a long sequence (of more than 2000 runs) stops after approximately 1700 runs.Temporary Solution:
Do not print the reports to screen. -or- Disable this single Windows XP setting "Use visual styles on windows and buttons". This is how one can reach it: On desktop's surface (i.e. Windows background) right click on MyComputer -> Properties. There in the System Properties dialog on the Advanced tab click Performance Settings button. There in the Performace Options dialog on the Visual Effects tab deselect / disable the checkbox "Use visual styles on windows and buttons" down in the list and leave dialogs with OK. Have all ChemStations closed first for this setting to become helpful.Fix Information:
Fixed in revision B.04.01.
In Data Analysis, load a sequence. From the reprocessing tools, load the sequence table. In any line, select the Method field, select "Browse...", but than press Cancel. Instead of falling back to the original method which was present before touching that field, the method field remaims empty. A warning is only displayed when you leave the table.Temporary Solution:
n/aFix Information:
n/a
In a dual injector B.02.01 system, when the customer saves the back injector in the sequence table and then reloads the sequence, it defaults back to the front injector instead of showing you the back injector. In version, A.10.0x, when you exit the sequence table while viewing the back screen, and you enter the sequence table again, the chemstation always defaults to the back. The customer wants the behavior to be the same with B0201 as A.10.0x. So, in a dual injector B.02.01 system, when you exit the sequence table you always return to the front.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
If you change the sample type of a run (that has not yet been executed) of a running sequence, the change in sample type will be ignored.Temporary Solution:
Change the sample type after the sequence has been completed and reprocess the sequence data.Fix Information:
n/a
The default hypersequence Def_LC.hyp can be overwritten after editing. The user is not forced to save the hypersequence with a different name.Temporary Solution:
n/aFix Information:
n/a
Running on a 7890A Back Injector only. Only the Back injector is available as the Injector selection, however, in the sequence table, both front and back are available for sequence input. The front will take back injector vial numbers and will not reject them. The front injector position should not be shown or accept vial numbers since it is not configured. When only the front injector is configured, the back injector position will also be shown in the sequence table. If the back injector is not configured, do not use the back injector in the sequence table.Temporary Solution:
n/aFix Information:
n/a
If the presence of the barcode reader is changed while ChemStation is connected to a 7890A, the availability of barcode options in the Sequence Parameters screen does not change until ChemStation is restarted.Temporary Solution:
n/aFix Information:
n/a
If on an 1100/1200 LC system a sequence is run that contains a line with vial number 0 (e.g. a sequence that has been created for a 1090 system), the sequence stops at this line without an error message that indicates the root cause. The cause is only documented in the sequence logbook.Temporary Solution:
n/aFix Information:
n/a
Create a CTC method and open the Sequence table Filldown Wizard. The three options for Increment direction seem to be mixing up the row and column for each selection such that they are creating a sequence that is the selection, but at a 90 degree angle from the selection. It sees 'rows' as A-G (short side of the rectangle); 'columns' as 1-14 (long side of the rectangle). For a VT-98 tray: Option 1 claims it will access vials from left to right, which should be A1-G1, according to their definition. However, it creates a sequence going from A1-A14, B1-B14, etc., front to back, front to back. Option 2 claims it will access vials from left to right in the first 'column', then right to left in the second, then left to right, winding back and forth. Instead, this winds back and forth, but front to back and back to front (A1-14, B14-B1, C1-C14...) Option 3 claims it will access vials from front to back, front to back across the 'rows'. Instead, it creates a sequence th at goes across each 'column' left to right (A1-G1, B2-G2).Temporary Solution:
n/aFix Information:
n/a
In a 1200 system with CTC sampler, sequences will stop after 422 sequence lines.Temporary Solution:
n/aFix Information:
n/a
Create a new seq from (DEF_GC.S) and add the first line to the sequence table. Copy and paste the next line causes the online session to shut down with no errors.Temporary Solution:
There are 2 workarounds: 1. Clear the clipboard in Excel. Go to Edit > Office clipboard. You should see the button to clear it. Then create the sequence table using copy and paste. 2. Close all the Office Applications before creating a sequence table. Clear the clipboard before closing the application.Fix Information:
n/a
If you inject samples using a sampler that can handle more plates than the 1100/1200 well plate samplers (e.g. CTC sampler), the follwoing problem can be observed: When injection from plates with plate numbers larger than 7, Data Analysis displays a strange sample location, like e.g. "- 20479".Temporary Solution:
n/aFix Information:
n/a
Unspecified error [Process Transforms] dialog box shown at the end of the sequence or partial sequence reprocess in an on-line session.Temporary Solution:
n/aFix Information:
n/a
In G2070BA, if you have the sequence running with Method A, it is not possible to edit Method A in the Offline session and save it so it can be used for the next sample in the sequence table.Temporary Solution:
n/aFix Information:
n/a
During the sequence, select pause. After the pause, open edit parameters and increased the oven hold time to 3 minutes and save the method. Resume the sequence. The method changes are not used when running with the Unique Folder ON.Temporary Solution:
n/aFix Information:
n/a
Select a method from the dropdown in the sequence table, the software doesn't have a browse... to select a method from another location. With Unique Folder = OFF, the "Browse" functionality is not available. The "Browse" is there if Unique Folder ON is used.Temporary Solution:
n/aFix Information:
n/a
The time stamps for sequence completion may differ between the sequence logbook and the instrument logbook: The sequence logbook lists the time after completion of the acquisition, while the instrument logbook displays the time after completion of the sequence summary report.Temporary Solution:
n/aFix Information:
n/a
In the ChemStation B.04.02 Pre-Release it is sporadically observed that ChemStation crashes after a sequence got aborted.Temporary Solution:
n/aFix Information:
n/a
When trying to open the sequence table while the sequence is running, the ChemStation may hang up. These cases are limited to very short time frames at the end and the start of a run.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
After stopping a sequence there is a short period of time where the Stop button is already active again, but the sequence is not stopped yet. When pressing the Stop button again during this time, it may happen in rare cases that the default data path is changed to "/".Temporary Solution:
Shut down ChemStation and start the Configuration Editor. The change the data path from "/" to the correct path. Per default this is "C:\Chem32\1\DATA\".Fix Information:
This problem will be fixed in revision B.04.02 SP1.
When partial sequence acquisition is executed into an exisiting sequence data container, the original sequence logbook gets overwritten by the logbook for the partial acquisition.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
Overlapped methods permit the pre-injection washes, rinses, and other actions
to occur on the next sample while the current sample is being analyzed.
The wrong sample can be injected by leaving the sequence table open until the
inject time. The data file, report, and sequence log file will not reflect
the actual sample vial which was used during the sequence.
The example below illustrates the problem of editing an overlapped method in a
running sequence.
Steps to reproduce:
1. Start sequence with overlap method: 101, 102, 103.
2. Allow the second line, vial 102 to do its prewashes, ending with the
needle holding in vial 102, waiting for the GC to finish.
3. Open sequence table and insert a line between the 2nd and 3rd lines,
designating to go to vial 101.
4. When the GC has finished, OK the sequence table to make the injection.
5. A third injection alone is made, without any overlap before it, to
vial 103.
6. Final sequence table shows 101, 102, 101 inserted, 103 (4 lines)
7. Results are as follows:
Seq table Report: Report: Actual injection Datafile
Sequence line Vial location location name
--------------------------------------------------------------------------------------------------
Line 1: 101 1 101 101 F0101.D
--------------------------------------------------------------------------------------------------
Line 2: 102
--------------------------------------------------------------------------------------------------
Line 3: 101 3 101 102 F0301.D
inserted
--------------------------------------------------------------------------------------------------
Line 4: 103 4 103 103 F0401.D
Summary: the Chemstation reports injecting vial 101 at sequence line 3 but in
fact injects the sample from vial 102.
Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
With ChemStation revision B.04.xx, it is possible to perform partial sequence acquisition into an existing sequence container when Unique Folder creation is switched on. When invoking partial sequence, the user is first asked to either select an existing data container or to create a new one. Afterwards, he selects the sequence lines to be executed for partial acquisition. When selecting an existing container, but afterwards canceling partial sequence acquisition and running a full sequence instead, ChemStation will not create a new sequence container, but the new data is acquired into the sequence container selected when canceling partial sequence previously.Temporary Solution:
n/aFix Information:
This problem is fixed in revision B.04.02 SP1.
At the end of the acquisition using a Purify Study, the following warning message is displayed "The system is unable to load a sequence while another sequence is running!", and the sequence does not complete until the user presses OK.Temporary Solution:
Click OK on the warning message in order to continue with your work.Fix Information:
n/a
When running a study with Purify add-on software, the following error message will be displayed at the end of running a study: "The system is unable to load a sequence while another sequence is running."Temporary Solution:
Close the error message by pressing OK before continuing with the next study.Fix Information:
n/a
When you try to use a method in the sequence table that contains an ' in its name, the ChemStation will crash when trying to leave the sequence table with the OK button.Temporary Solution:
n/aFix Information:
n/a
A Microsoft .NET Framework exception may occur when stopping a sequence immeadiately after start of the sequence. Afterwards, the sequence will not restart.Temporary Solution:
Shut donw and restart ChemStation.Fix Information:
n/a
The following problem occurs when there are data paths specified in the Preferences dialog that no longer exist. When opening the Partial Sequence dialog in this situation, ChemStation will crash.Temporary Solution:
In the Preferences, remove all non-existing data paths.Fix Information:
n/a
Partial reprocessing takes very long for long sequences even when reprocessing only a small part of the sequence.Temporary Solution:
n/aFix Information:
n/a
When storing spectra during peaks, the spectrum for the apex may be collected at the wrong point in time, depending on the detector peakwidth parameter.Temporary Solution:
The instrument hardware’s peak detection algorithm has to identify start, slope, apex, and end of a peak in order to be able to send the correct spectra to the ChemStation software. The results of this process are influenced by the sampling rate / peak width of the detector. The peak detection algorithm of the detector hardware performs best when c. 15 data points per peak are collected. In order to account for broadening of peaks at the end of the chromatogram use the Peakwidth option of the timetable. Peakwidth changes the filters used for peak-controlled spectra acquisition, but not the data rate of a chromatographic signal.Fix Information:
n/a
When there are unsaved changed both in the currently loaded spectra library and the currently loaded method and the user finally saves the method changes, a message comes up asking him whether he wants to save the library with the method. If the user acknowledges this message with Yes, the library will be stored in the method folder of the currently loaded method. This even happens if the method does not reference the library in the library search options or does not use library search at all.Temporary Solution:
n/aFix Information:
n/a
When creating a spectral library entry from an exisiting data file, the text in the Sample Information of the data file is not used to automatically populate the Info field of the library entry.Temporary Solution:
n/aFix Information:
n/a
Independently of the wavelenth range in the method, the online plot will only display the wavelength range 190 - 400 nm for the DAD G4212A.Temporary Solution:
n/aFix Information:
n/a
When creating a spectra library entry by extracting a spectrum from a data file, the Sample Information of the data file should be added to the library entry. However, this functionality does not work in ChemStation B.03.01 and higher.Temporary Solution:
n/aFix Information:
n/a
Using a system with two or three Fraction collection modules (but no recovery Fraction collector set) the first Fraction collector will show the message "Could not find a valid next position" even if that event occured on one of the other Fraction collectors. If a system is used as recovery fraction collection, the message is shown at the right module.Temporary Solution:
The graphical userinferface will give the right information about the event occured. In case this error message pops up, the user should watch the Fraction collector modules, to see which one is causing the problem.Fix Information:
n/a
Compaq chemstation bundle PC EVO 510 only: Prod ID: X1155AV with Windows 2000, SR 2 or SR3 In Data Analysis signal Tasks the Time Reference Lines are not shown when selected.Temporary Solution:
The solution will be to change the hardware acceleration for the video card from the desktop properties. Beware system settings True color 32-bit and a resolution 1024x768. To perform the change: 1. right click on desktop --> select Properties tab 2. set colors to true color and resolution to 1024x768 à go to advanced button 3. select Troubleshoot tab à access to slid bar for hardware acceleration on the video card. 4. Set the hardware acceleration to NONE.Fix Information:
No fix is planned for this problem.
When the operator name is changed in the Change Access Level dialog, only 29 characters are saved, but no warning is displayed, if more than 29 characters are typed in the dialog.Temporary Solution:
Specify operator name with less than 30 characters.Fix Information:
No fix is planned for this problem.
Sporadically it was observed that the ALS remains in running state in the Diagnosis view after running Column Thermostat test.Temporary Solution:
In case the problem occurs, terminate the test manually by Abort.Fix Information:
No fix is planned for this issue.
A run with one more signals was acquired using fraction collection. In the chromatograms the fraction times are correctly displayed with the correctin by delay time of the detector applied. In the fraction table below the chromatograms the uncorrected fraction times should be listed because the table is not linked to a particular signal. However, the actually displayed times are corrected by the largest delay time in the signals.Temporary Solution:
n/aFix Information:
n/a
When EMPV Cleaning Procedure for a preparative pump is performed, at step 6 (Test EMPV leak) the status remains "Waiting" even when "Continue" button is already available.Temporary Solution:
Press "Continue" button when it is available to continue with the EMPV Cleaning Procedure.Fix Information:
No fix is planned for this problem.
If the "Peak Detectors" table in the "Set up Fraction Collector" is edited while the fraction trigger mode is "Off", only the changes for upper threshold are retained, while the edits for up slope, down slope, and threshold are discarded upon leaving the "Set up Fraction Collector" dialog.Temporary Solution:
Only edit the "Peak Detectors" table when the fraction trigger mode is "Peak-based".Fix Information:
No fix is planned.
There is no fix planned for this problem.Temporary Solution:
This is only a graphica interface issue. The correct value is taken where the mouse was clicked, and this value is taken into the table and used for fraction collection.Fix Information:
n/a
For ChemStation Rev. A.10.x following issue as been reported for graphical information. Using the overlay function for datafiles within the Data Analysis- Integration task section, the datafile information in the lower left corner are displayed when a signal channel is selected. Using this option the file information box will be updated with the correct information except the file name, which will refer to the first loaded datafile of the overlaid set.Temporary Solution:
The correct file name is displayed in the header of the loaded chromatogram.Fix Information:
n/a
Under the following issue has been reported using a Matrox Millenium G450 or G400 graphic card : Zooming several times into a Datafile by using only a small area of the y-axis strange veritacal lines might be seen in the Datafile.Temporary Solution:
This is a hardware issue and cannot be solved within the ChemStation.Fix Information:
n/a
Within different views of the ChemStation it is possible to have multiple items on the screen, now using the "print window" option not always the expected window is printed: E.g.: 1. load multiple signal, switch to single single view -- ALL signals will be printed, not only the selected one 2.With the chromatogram and integration items on the screen, it is not possible to define an active windowTemporary Solution:
n/aFix Information:
n/a
When you open the Current Logbook in Method and Run Control view, the corresponding window shows the three standard boxes to handle the size. While the other two items are available, the Minimize box cannot be used.Temporary Solution:
Resize the window manually by using the mouse and drag the corner of the window.Fix Information:
n/a
When an online session of ChemStation is closed, the user always gets asked whether he wants to switch the column thermostat, pump and detector lamps - even when the user already switched off the instrument manually before.Temporary Solution:
n/aFix Information:
n/a
Using B.01.03 and fraction colletion system, the fraction table in the Data Analysis view "select Fraction Task" can disappear when switching to OQPV context and back again to Data Analysi.Temporary Solution:
n/aFix Information:
No fix is intended for this issue.
In a system with two DAD detectors, e.g a DAD G1315B and a G1315C, in the online it is very difficult to differentiate which of the signals belong to DAD1 or to DAD2, respectively.Temporary Solution:
Display the Instrument Actualsto differentiate between the two DADs.Fix Information:
No fix is planned for this issue.
In Verification view select either Injector Precision/Carry Over or Response Linearity test. In the setup for these tests only the following detector types are available: EI, APCI and APPI, while MultiMode Source is missing.Temporary Solution:
Execute the OQ/PV with customized verifications using the MultiMode Source.Fix Information:
n/a
Using ChemStation Rev. B.02.01 running a fraction collector in recovery mode, the Instrument Actual panel will still say "Recovery No".Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using ChemStation B.02.01 running a Chip Cube module. If the LC tower is going into an error state and the sychronization of each module is lost, all LC modules will show an error , the Chip Cube instrument actuals will still indicate the Chip Cube in a working state.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
Following issue has been reported using ChemStation B.02.01 and manual injectors: In the graphical user interface, the injector is not labeled as "Manual" when in manual mode.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using ChemSTation B.02.01 OQ/PV in Verification, running enhanced Tests on the Fraction Collector: Creating a new verification file perfom the tests and define in Instrument Verification some Required vials the "Sample Info" of the Fraction collector tests mentioned tests show four bars (||||) instead of spaces in the description.Temporary Solution:
n/aFix Information:
n/a
The Windows error System.NullReferenceException may occur during repetitive ChemStation operations (doing something > 1000 times).Temporary Solution:
This is a Microsoft Window XP SP2 bug. For more details please go to http://support.microsoft.com/default.aspx?scid=kb;en-us;319740 User will not use msprofile as much as testcase does (1000+ times). There also have a workaround available: WORKAROUND If this GDI leak is seriously degrading performance, you can turn off the new user interface theming in Windows XP. To do this, follow these steps: 1. Click Start, and then click Control Panel. 2. Click Appearance and Themes, and then click Display. 3. On the Themes tab of the Display Properties dialog box, click Windows Classic in the Theme list. 4. Click Apply, and then click OKFix Information:
n/a
Toolbars can only be configured (e.g. selection which icons are displayed) when they are dragged to be displayed in separate window.Temporary Solution:
n/aFix Information:
n/a
Select View -> Preferences. On the Paths tab, press one of the Add buttons. In the upcoming dialog it is possible to create a new folder only with Windows 2000.Temporary Solution:
n/aFix Information:
No fix is planned for this problem.
Using Firmware A.05.11 running with ChemStation B.01.03 the following has been reported: in case of a defective pressure sensor a wrong error message is displayed: Instead of the error message "invalid pressure signal", the message " pressure sensor not connected," is coming up.Temporary Solution:
n/aFix Information:
n/a
Using ChemStation B.02.0x the pressure signal plot for the PrepPump is missing in Online Plot as soon as the user switches to the Diagnosis view and back again. 1. In Method and Run Control online plot view the pressure signal. 2. Switch view to View - Diagnosis: pressure signal plot present 3. Switch back to View - Method&Run Control: no pressure signal plot presentTemporary Solution:
n/aFix Information:
n/a
Following problem has been reported in ChemStation B.02.01 using Prep Pumps in the system: There is no “Solvent” in display of Set up Gradient dialog box of the Prep Pump.Temporary Solution:
n/aFix Information:
n/a
Occasionally, when the ChemStation is started or shutdown, these errors are observed: “FetchCPVar Cannot talk to Application” “Error Fetching CP Variable _GUIFInjUpperVial” “Error Fetching CP Variable _GUIBInjLowerVial” “Error Fetching CP Variable _GUIBInjUpperVial”Temporary Solution:
n/aFix Information:
This problem does no longer occur in revision B.04.02 SP1.
There is a disagreement between GC and Chemstation Status for Splitless Methods with regard to Prep Run
The chemstation status should say:
"Splitless Inlet Waiting for Prep Run" and
the "Not Ready" should be in Yellow for example
The status is confusing.
Temporary Solution:
n/aFix Information:
n/a
Since revision B.02.01, the available function keys are no longer displayed in Method and Run Control view. This affects both the default function keys and additional function keys introduced via the SetFKey command.Temporary Solution:
n/aFix Information:
n/a
The Initial Screen Window Size can be changed randomly if the Initial Screen Window Size is set to Normal and then the Chemstation is closed when iconized in the taskbar. The Chemstation.ini will have the WinSize value = Min and when the Chemstation is started, the error occurs. If the Chemstation is closed when the ChemStation window is maximized, then the WinSize key will be set to Normal and no errors occur on start up. So, if the ChemStation is iconized to the taskbar and the user right-clicks on the icon to close the chemstation, the autostart Macro Failed, error# 999 will occur when starting the Chemstation.Temporary Solution:
In Chemstation.ini, if the WinSize value = Min, change the value to Normal before starting the Chemstation. [PCS,1] InstType=gcoffline InstName=Instrument 1 WinSize=Normal Use the Configuration Editor to set the Initial Screen Window Size to Normal.Fix Information:
n/a
With the 7890A method and run control view selected with instrument diagram, ChemStation status, online plot, and Agilent GC status enabled, the ChemStation Status and the Agilent GC status do not indicate in the title bar (color change) when selected. Instrument diagram and on-line plot do work correctly.Temporary Solution:
n/aFix Information:
n/a
When the user enters a command in the command line, while ChemStation is busy and displays the corresponding indicator, ChemStation will hang up. In this state, ChemStation has to be terminated via TaskManager.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
When a network path has been configured as data path in the Preferences dialog, this data path will be available in Data Analysis view in the ChemStation Explorer. After a network interruption and following restoration, the network path is displayed in ChemStation Explorer again, but it can not expanded anymore to access the data.Temporary Solution:
Close and restart ChemStation.Fix Information:
n/a
Headspace software error box is not displayed until the HeadSpace application has the focus. The user is not shown the error box until selecting the Headspace software user interface.Temporary Solution:
n/aFix Information:
n/a
ChemStation B.04.01 CTC A.01.04 During the CTC process cycles of pre and post run, ChemStation Elapsed time is showing -1.0 This is not while the GC is in a run. Set up a CTC run with pre and post run cycle activities. (Prewashes and Postwashes) Run Method. During the pre run before the GC starts, the elapsed time will show -1.0 After the GC run is completed, and the Post run CTC events begin (post washes), the GC elapsed time will show -1.0Temporary Solution:
n/aFix Information:
n/a
In B.04.01 SP1 it is no longer possible to have both a directory and a subdirectory of this directory in the Data Paths settings (Preferences dialog) specified at the same time.Temporary Solution:
n/aFix Information:
This functionality will be available again in revision B.04.02 SP1.
The chemStation UI uses mixture of color settings from Windows and Configuration Editor.Temporary Solution:
n/aFix Information:
n/a
When using RC.NET drivers for the LC instrument signal description in the online plot does not provide wavelength information for the detector signals.Temporary Solution:
n/aFix Information:
n/a
When switching to the Verification view for the first time, this view does not initialize correctly. The icons below the menues are not displayed.Temporary Solution:
Switching to Method and Run Control and then back to Verifation resolves the situation.Fix Information:
n/a
It is not possible to move Edit Integration Events dialog. If you try to move the dialog, only the upper part of the window moves.Temporary Solution:
n/aFix Information:
n/a
When using the new RC.NET drivers for LC ChemStation and therefore the new UI for Method and Run Control, the indicator for unsaved changes of a method is difficult to see because of its small size.Temporary Solution:
n/aFix Information:
In revision B.04.02 SP1, the method change flag will be larger.
The entry in the menu reads: "Save Sequence Template". The header of the corresponding dialog reads: "Save Sequence". It should read "Save Sequence Template" in both cases.Temporary Solution:
n/aFix Information:
n/a
If a hypersequence that contains of several sequences for one plate, "Stop Hypersequence" does not stop the hypersequence after the current sequence, but only after all sequences on the plate are completed.Temporary Solution:
Use "Stop Sequence" to manually stop each single sequence running on the plate or use "Abort" directly after completion of the current sequence.Fix Information:
There is no fix planned for this problem.
Installing ChemStation Rev. B.01.01 ChemStation on a system using Symantec's PC Anywhere version 10 following error messga come up during starting the ChemStation: "Entry point not found in util.dll." PC Anywhere and the 32bit ChemStation software have a dll with the same name (util.dll).Temporary Solution:
Symantec PC Anywhere is not supported using ChemStation Rev. B.01.01 Renaming the PC Anywhere's dll (or deinstalling the PC Anywhere software) allowed ChemStation to load. Path information: C:\ProgramFiles\Symantec\PC AnywhereFix Information:
n/a
With ChemStation Rev. B.01.01 and Excel following issue has been reported: The "paste special link" in Excel is not working immedeatly for ChemStation created linked .xls files: Conditions: Creating a ChemStation report using the "print to file" option in specify report a report01.xls file including all result information is created. Opening this file and 1. create a "new" excel workbook 2. copy the line of interest in the chemstation report01.xls and paste that information into the new workbook using the "paste special", "paste link" function in Excel/Edit. Save the new workbook under a specific name. 3. Close Excel 4. Open the new created workbook: a message appears and informs the user that this Excel workbook is linked with the report01.xls file and if this link should be executed: Answer YES 5. The system comes back telling: Unable to read data.Temporary Solution:
The following workaround can be used: Open the ChemStation report01.xls file, than save it and close the file. Now the link will be executed. For audit reasons it would be a possibility to 1.print the excel report before and after saving the file in excel, to ensure that no changes have been taken. 2. save the excel file under a different name. The link issue will be solved due to saving the file. In addition the original file will still be available for comparison.Fix Information:
No fix is planned for this problem.
Using english ChemStation B.01.01 and English Operating system, but changing the fonts to Japanese the values in the e.g. pressure fields will be set to a strange value.Temporary Solution:
n/aFix Information:
n/a
Some customers have asked for the ability to view fraction information in the ChemStation’s Data Analysis Spectral View. This way they can see both the start and stop times of their fractions, and select spectra from the peaks.Temporary Solution:
n/aFix Information:
n/a
Using ChemStation B.01.01x following issue has been reported using the XML functionality: As soon as a Sample Amount is predefined in the XML import file, the import of LimsId fails during "import worklist".Temporary Solution:
The problem is only seen using a comma instead of a point in the number section Sample Amoung: Because the XML file gets converted into CSV-file (literally COMMA SEPARATED...) the values for Sample Amount which contain "," (e.g.: "274,42") will break the structure of the file and confuse the parser engine. So the values have to be setted using a point. or After the import of the XML worklist the sequence table need to be checked and the Sample Amount need to be added manually.Fix Information:
No fix is planned for this problem.
Inserting Chemstation *.emf files created via printing reports to file into other applications leads to oversized images. The pictures have to be resized afterwards.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using the 3D overlay window in ChemStation B.01.03.: In the 3D overlayed moded It is not possible to 1. add annotations 2. move annotationsTemporary Solution:
Following workaround does solve the issue: Both issues can be solved, when the chromatogram is ins “overlayed mode”,”display each in full scale”. Only than go for the 3D overlay mode. If this is not working, select the “draw line” tool (3rd tool in the annotation list on the right site, to be enabled by Grpahics tool bar, Annotations) and click into the 3D overlay screen, than change to the e.g. the annotation item and the annotations can be written .Fix Information:
n/a
Following issue has been seen executed the OQ/PV test Injector Precision on a micro system with a 20ul/min sensor, using ChemStation B.02.01: If the measure and calculation of Carry Over Area and Height precision result in negative values, the test is shown as passed.Temporary Solution:
n/aFix Information:
n/a
When an hardware error occurs during execution of the Holmium test, the Diagnosis view will nevertheless display the results from the last time the Holmium test has been successfully.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using ChemStation B.02.01 performing the flow sensor calibration test in Diagnosis: If the pump is not switched on while starting the the Capillary Flow SensorTemporary Solution:
Ensure to switch on the pump prior running the Cap. Pump Flow Sensor Calibration test.Fix Information:
n/a
Following issue has been reported for some OQPV tests running on ChemStation B.02.01. After closing the a performed OQPV test, the setup dialog box of the used module might greyed out.Temporary Solution:
If the problem occurs, please load another method, e.g. default method and all set up dialog boxes are available again.Fix Information:
n/a
If the Purity Data Base Path is set to C:\ (Options -> Set Data Base Path), the following error will occur when trying to open a study: "Critical error 52 in frmStudyOpen.Form_load Bad file name or number". Afterwards Purify crashes.Temporary Solution:
Do not set the Data Base Path to C:\, but use any folder on C:\ instead.Fix Information:
No fix is planned for this problem.
When the Noise and Temperature Stability test for an RID detector is set up and the user enters the limits for noise values, the unit is given as mAU, but it should be nRIU. The same problem is also observed in the report.Temporary Solution:
n/aFix Information:
n/a
Following problem has been reported using the isoplot in ChemStation B.02.01/B.02.01 SR1 to extract signal to Data Analysis. The selected extracted signal in the isoplot is reduced by one nm as soon as a Bandwith is set. This reduced signal is than exported to Data Analysis.Temporary Solution:
n/aFix Information:
This behaviour is correct. Because not every wavelength is inside the library the closest avaible one is choosen. Depending on the acquired spectras and on the choosen bandwidth not all wavelength are possible.
Following item has been reported on ChemStation B.02.01/B.02.01 SR1 using the Autosampler tests in diagnosis view: Performing the action DRAW or PLUNGER HOME in the Injector steps, the action icon turns red under the following circumstances: Entering directly a volume 100µL the action icon turns red.Temporary Solution:
The problem is only graphical nature. Incrementing the draw volume by steps of 10µL till getting 100µL, there is no problem in the User interface.Fix Information:
n/a
Perform a run in ChemStation Rev. B with the column information set, and create a performance report: If a Void Volume is specified in the column, you ahve to take care to specify a void volume that corresponds to a void time that is within the actual run time of the method. Otherwise, K Prime is not calculated.Temporary Solution:
n/aFix Information:
n/a
For some reports printed with various Printer drivers using ChemStation Rev. B following problem has been reported, printing a zoomed chromatogram: If one peak is very big and the user is zooming into the smaller peaks, the big peak might be printed incompletely.Temporary Solution:
The problem is printer driver related, using the printer driver LJ 4200 PCL 5e or the Postscript driver, the problem is not present.Fix Information:
It is currently not planned to fix this problem.
Following item using the Annotation Menu in ChemStation B.02.01 SR1 has been reported: As soon as the annotation menu is opened once, the annotation menu settings are the master of the graphics settings used as well in Graphic, Signal options. Settings defined in the annotation tool set are used.Temporary Solution:
n/aFix Information:
n/a
Following item has been reported using ChemStation B.02.01/B.02.01 SR together with a Instand Pilot Handheld Controler: Defining a setting for the solvent compressibility calibration in the ChemStation and then change the value using the Handheld Controler "Instand Pilot" the Auxiliary dialog checkbox "use enhanced comp. calibration" is still checked afterwards in ChemStation. The correct value for the composition, set using the Instand Pilot, is shown (grayed out) in the edit field.Temporary Solution:
n/aFix Information:
n/a
Following problem has been reported using the external contacs board in a G1367C injector. Selecting the "contacts" option in "more injector" and select "use BDC port for" "Binary Output" . After pressing "OK" the following error mesage occured: "The Parameters could not be transmitted correctly! Please re-check your settings. "Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using fraction collection on ChemStation B.02.01 : If the first sequence table line is set up a reserved location for fraction collection, there error message "invalid start location" is coming up.Temporary Solution:
n/aFix Information:
No fix is planned for this issue.
Generating XLS reports in ChemStation B.02.01 SR1, the generated file REPORT02.CSV contains two strange charatcers whem loaded with Excel.Temporary Solution:
n/aFix Information:
n/a
Following issue has been reported using ChemStation and Purify Add-On software: When creating a new studies it is possible to add an information in the "Description" field. Setting up multiples studies based on the same original study with various descriptions, the sample in general get the description of the first study assinged. The samples in unused vial positions will get the new sample description .Temporary Solution:
Please specify or change the sample description in Study List for each sample and not in the general setup.Fix Information:
n/a
Following issue is been reported using the Micro ALS on ChemStation B.02.01/B.02.01SR1: After exchange a 100 vial tray with a 15 vial tray by inserting the 15 vial tray at right or left position, than then running the sequence using the tray on the left position. An error message "location: vial must be in.... range " occurs, if the vial position is set to higher than 15 in sequence line.Temporary Solution:
n/aFix Information:
n/a
Following problem with zooming has been reported using ChemStation: If the settings in Data Analysis, Graphics, Signal Options, Multi-Chrom., are set to "seperate" and "each in full scale" , the zoomed file is set back and the full chromatogram is exported.Temporary Solution:
Ensure to set the settings in Data Analysis, Graphics, Signal Options, Multi-Chrom., Scale to "all in same scale", the zoomed file is exported.Fix Information:
n/a
The following problem has been reproted for ChemStation B.02.01 using in Diagnosis the Fraction Collector Single Step: If move to Location is set for Vial 1 - 9, the test is executed. If Move to Location is set for higher vials the error ‘Location not Valid’ error occurred, entering number above 10.Temporary Solution:
Please use the required syntax: Vial 1, Vial 2,...., Vial 10, ....Fix Information:
n/a
The folliwng problem has been seen in ChemStation B.03.01 printing to the specific excel sequence summary template HPSEQ00 Template using a post-sequence macro. The macro is not executed correctly, no report is created.Temporary Solution:
n/aFix Information:
n/a
All Prep pump signals disappear from online plot when switching from Method and Run Control View to Diagnosis and back to Method and Run Control. G1361A A.06.04 x2 G2260A A.06.04 G1365B A.06.04 G1364C A.06.05 This symptom is seen only when switching to Diagnosis view. Switching to other views (Data Analysis, Report Layout, OQ/PV) does not result in this problem.Temporary Solution:
Reselect the Prep Pump Online Signals again.Fix Information:
n/a
Following issue has been reported using batch menu in ChemStation B.02.01 and higher: Loading a batch . b , it is possible to select a method to be used with batch. The user can pick a method, and the method is than loaded together with the batch file. If in Data Analysis a method is currently loaded on the e.g. D drive (methodA.m) , and the user select a method on the C drive (methodB.m), the system is NOT able to load the selected method. The system is loading the method from the sequence container.Temporary Solution:
In the Data Analysis view, load a method which is in the same drive and directory like the method you want to pick for the batch view, and than it is possible to load a method from another drive.Fix Information:
No fix is intended for this problem.
Export of MS data to AIA format directly onto network drive crashes ChemStation. Afterwards ChemStation cannot be restarted, and the ChemMain.exe process has to be terminated in Windows Task Manager.Temporary Solution:
Export the AIA data to a local drive and transfer them to the desired server location later on.Fix Information:
n/a
Installation packages for Acrobat Reader are provided on ChemStation CD 2 in English, Chinese, and Japanese. However, it is impossible to install Acrobat Reader with the English package. Installation fails with error message: "This program is used internally by PackageFromThe Web. It should not be executed directly."Temporary Solution:
Download Acrobat Reader from Acrobat webpage.Fix Information:
n/a
The link to the base reference file IQTREF.XML on IQT Report is not working.Temporary Solution:
The file is located at \chem32\core.Fix Information:
n/a
A modified or corrupt base reference file IQTRef.xml causes a crash of IQT Report tool.Temporary Solution:
n/aFix Information:
n/a
If previously a sucessfull IQT was performed, a further IQT Report will still show the result as "Passed" in case the base reference file IQTXref.xml was deleted. The previously generated report is shown instead of a new report.Temporary Solution:
By the date and time stamp the user is able to detect that the report originates from a previous run of the IQT Report tool.Fix Information:
n/a
Japanese or Chinese Excel will by default save .csv files in ASCII format. ChemStation Sequence Import requires the .csv files to be in Unicode format.Temporary Solution:
Open the .csv file from Excel with Notepad and save it as .csv file (coding: Unicode).Fix Information:
No fix is planned for this problem.
After switching to Diagnosis view, IQT Report may fail with the following files reported as invalid because of checksum mismatch: \chem32\lc\800\dgdetect.ini \chem32\lc\800\dgdetec5.ini This problem occurs with LC/MS systems. The change in the two .ini files causing the checksum mismatch is correct behavior.Temporary Solution:
n/aFix Information:
n/a
The ChemStation Operational Qualification tests reporting and integration through the use of verification files (.val files). The location of the spectral library is part of the canned method. When any 3D ChemStation is installed onto a drive other than C:\, then the library search verification file will fail the integration and quantification tests. This failure is a result of the default drive & path for the Spectral libraries (SPECLIBS) listed in the method that is used in this test.Temporary Solution:
See Service Note CECHEM-006Fix Information:
This problem will be fixed in revision B.04.02 SP1.
The values of compound custom fields are only exported to the result.xml file for a run, if the compound is actually found in this run.Temporary Solution:
n/aFix Information:
n/a
If export of result information to xml is enabled, the module name is not exported to the result.xml file.Temporary Solution:
n/aFix Information:
n/a
When having the LC instrument configured with RC.NET drivers, it may be observed that the software verification tests (using the .val files) fail. The methods used for the tests will be marked as changed,at the same time.Temporary Solution:
n/aFix Information:
This problem will be fixed in revision B.04.02 SP1.
When running the verification tests FLDARPC.VAL or interactively loading the method FLDARPC.M a message comes that the method needs to be migrated to the new spectra tool set. The test will nevertheless pass when pressing OK this message.Temporary Solution:
In case the method is marked as changed, do not save the changes. Otherwise, the verififcation test would fail in the future.Fix Information:
n/a