MassHunter IM-MS Browser Build 104.0 This build is “lightly tested” and is for Internal Use Only As with the B.06.00 release (B27), this version of the Browser should be paired with MassHunter Qual B.07.00 Prerelease (Build 744.0). This build includes a few enhancements compared to the current release (B.06.00, Build 27.0), especially in the cross section calculator. It also includes fixes for a number of other issues (mostly minor). See below for the location of installers and the list of the changes in build with associated TeamTrack issue numbers. Regards, IMS Browser Team Software Installers: Browser: \\tcfiler1\v70\lcmssoftware\LSBU\Mercury\Installers\ImsBrowser_B104.0_Release_Installer.zip Qual: \\tcfiler1\v70\lcmssoftware\LSBU\Mercury\Installers\PreRelease_Qual\Qual_B744.0_ReleaseInstaller.zip Documentation: See the on-line help in the Browser Software Changes: Cross Section Calculation Issues 222384 When printing the Cross Section Calculation Table with all digits visible in the UI, the printout truncated values in several columns 222387 When exporting the table from the Cross Section Calculator Window with space as a delimiter, many column headers are split due to containing spaces 222200 After highlighting multiple points on Cross Section Plot, click to display context menu changes highlight to only one point 222293 Substituting Highlighted Points in Cross Section Calibration Plot sometimes ADDS points as additional points in the table 224791 Exception when deleting point from cross section calculator plot 222382 When copying or exporting the Table or the entire content from the Cross Section Calculator Window to the Clipboard, the K0 values are all zero. Cross Section Calculator Enhancements N/A Add Cross Section Calculator support for drift gases other than Nitrogren 227194 Browser should use drift tube length of 781 mm +/- 0.5 mm 224526 CCS calculator should show units for K0 and it's StdDev 224527 CCS should show number of rows more clearly 224528 CCS calculation need better warning message when Z can't be determined 224529 Delta CCS can be confusing when not doing a calibration 224530 CCS calculator should report standard error of y for t0 (Enhancement) 224525 Reduce width of some CCS calculator text boxes to save space 222475 In the Cross Section Calculator, double-clicking in the input value fields, or any field in the first three columns of a populated table, gives access to an enhanced context-sensitive menu(and should not) Other Enhancements 225353 Want a Browser option to clear all custom spectra in Frame Viewer at once (Enhancement) 223078 Need progress bar for Method | Go to bookmark if the bookmark involves summing frames (Enhancement) 223602 Add option to position horizontal 2D plot in Frame Viewer above (rather than below) heat map (Enhancement) (not implemented as optional; it’s always that way!) Numeric Precision Issues 222654 Menu item Configuration > Numeric Precisions > Drift Time > Resolution does not work 222655 Menu item Configuration > Numeric Precisions > Mass > Resolution does not work 222727 Menu item Configuration > Numeric Precisions > Other > Cross Section in Square Angstrom gets applied in the Results section of the Cross Section Calculator, but not in the table column 222729 Menu item Configuration > Numeric Precisions > Other > Field in delta V / cm does not get applied either in the Frame Information 222730 Menu item Configuration > Numeric Precisions > Other > Voltage does not get applied in the table column in the Cross Section Calculator window, nor the table column in the Cross Section Calculator Exceptions 223015 Exception when trying to set heat map plot options with no data file open 222472 Exception when trying to create a polygon where the third point is back on the first point 224523 Exception if user enters text into the heat map plot options "Abundance Encoding" combo box 221912 Browser creation of filtered .d file fails at end (with exception) if the source file's acquisition is not complete. 223017 Exception when moving splitter in Frame Viewer Incorrect Behavior 222653 When changing extraction threshold, clicking OK and selecting next frames via Prev/Next or double-click in File Overview, first selection does not update frame heatmap 222189 Export of user drift or mass spectra to a delimited text file with space - Opening quote positioned in 2nd position 221347 Browser 2D plots don't always zoom correctly with double-click on X or Y axis 220431 Closing the data file in the Browser doesn't clear the current contents of the drift or mass spectrum peak tables Minor UI Issues 218712 Remove "CenterX" as peak label option and use "m/z" or "drift time" 220993 When using the windows taskbar to bring an open dialog box in focus, the main browser window stays in the back 222297 The "Unzoom" command in the context menu (and CTRL + Z) of the User Drift Spectra and User Mass Spectra Window are limited to reverting 5 steps of zooming. 221819 Combo box for File Type in the Frame Export Options from the Frame Viewer Heatmap is a bit short 219303 User Spectra Data Windows: in the toolbar, when in Overlaid mode, hide the "Number of Visible panes" edit box. It is only valid when user is in List mode. 222521 Open Method... and Save Method As... dialog boxes need to have proper titles 222651 IM-MS Reprocessor menu item shows up at wrong level in Start Menu