HP 10086A ECL Terminator

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
ECL signals are normally offset from ground, while high frequency test equipment generally provides 50-ohm termination to ground. Attempting to connect an ECL signal directly to the test equipment could result in either damage to the ECL output or to the test equipment.

The HP 10086A ECL terminator provides an excellent interface between ECL outputs and test and measurement equipment.

The terminator offsets and attenuates the signal sufficiently to protect the test equipment, while providing the proper termination voltage between the ECL circuit and the test equipment. The HP 10086A can also be used alone to properly load an ECL output. The ECL terminator is a precision adapter that is dc-coupled to the instrumentation. This allows direct measuremnt of your ECL signal. Power supply adjustment and capacitive or transformer coupling are no longer necessary with the ECL terminator. In addition, it is no longer necessary to float the instrumentation ground to -2V, thereby reducing the hazards of power supply shorting and electrical shock or damage to the circuit.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Attenuation:		10X ± 1.0 % at dc or 
			20 db ± 3 db, dc to 10 GHz  

Abberations: 		±3 % maximum, with 100 ps rise time  

Maximum Input Voltage: 	± 5 V on all inputs 

Connectors: 		ECL input SMA (m)  
			ECL output SMA (f)  
			Bias input SMB (m)  

The following table indicates the typical bias voltage 
required to set the proper termination voltage:  

			 Vcc      Vee     Vterm     Vbias  
			0.00 V  -5.20 V  -2.00 V   -2.45 V    
			2.00 V  -3.20 V   0.00 V    0.00 V   
			5.20 V   0.00 V   3.20 V    3.92 V 

Dimensions(including connectors): 
			1.50 x 1.10 x 0.45 inches 
			(3.81 x 2.79 x 1.14 cm)


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 10086A      ECL Terminator


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Monday October 05 19:08:43 UTC 1998