HP 10896B Laser Compensation Board for VMEbus![]()
|
For greatest accuracy and repeatability, an HP 10717A Wavelength Tracker can be used to provide measurement repeatability up to +/-0.14 ppm. This technique uses an additional laser axis and tracks changes in the air's index of refraction.
As part of an HP VMEbus positioning system, the HP 10896B can be used to improve performance in applications using IC manufacturing equipment (wafer steppers, E-beam systems, and flat-panel steppers), precision machine tools, and custom stages. The exceptional accuracy of the laser system allows the precise positioning and motion control required for the consistent manufacture of high-quality products.
![]() |
Because each measurement depends on the wavelength-of-light (WOL) as its basic scale length, changes in air temperature, pressure, humidity, and gas composition change the air's index of refraction, which in turn changes the WOL in air. The HP 10896B uses the HP 10751C/D Air Sensor to measure and compensate for the changes. |
![]() |
Thermal Expansion |
![]() |
Measurement errors can result from thermal expansion of the workpiece or machine being measured. Up to four HP 10757D/E/F Material Temperature Sensors can be used to measure material temperature and to compensate for thermal expansion errors. |
![]() |
HP 10896B Laser Compensation Board for VMEbus Opt 002 2 Axis Interconnect Cable Opt 003 3 Axis Interconnect Cable Opt 004 4 Axis Interconnect Cable Opt 005 5 Axis Interconnect Cable Opt 006 6 Axis Interconnect Cable Opt 007 7 Axis Interconnect Cable Opt W50 5-Year Return Repair Service ![]() ![]() ![]() ![]() ![]() ![]() ![]()
|
Page Updated: Thursday November 13 07:38:39 UTC 1997