HP 1660CS 136-Channel 100MHz State/500MHz Timing Benchtop Logic Analyzer w/ 2-Channel Oscilloscope![]()
|
It adds two 1-GSA/s digitizing scope channels for viewing the analog behavior of your signals. Both channels capture non-repeating events simultaneously with 8K samples per channel. Characterize critical timing parameters with time interval measurements of better than 150 ps accuracy, or examine glitches in your system to determine if noise or loading is a problem.
State and Timing Channels: 136
Oscilloscope
Channels: 2
Sample Rate: 1 GSA/s
Bandwidth: 250 MHz
Vertical Resolution: 8 bits
Memory Depth: 8K
Timing Analysis
Conventional: 250 MHz all channels, 500 MHz, half channels
Transitional: 125 MHz all channels, 250 MHz, half channels
Glitch: 125 MHz half channels
Sample Period Accuracy: 0.01% of sample period
Channel-to-Channel Skew: 2ns, typical
Time Interval Accuracy: ±(sample period + channel-to-channel skew = 0.01% of time interval reading
Min. Detectable Glitch: 3.5 ns
Memory Depth Per Channel: 4K per channel, 8K in half-channel modes
State Analysis
State Analysis Speed: 100 MHz all channels
Setup/Hold Time[1]: 0/3.5 ns through 3.5/0 ns, adjustable in 500 ps increments
Min. State Clock Width: 3.5 ns
Time Tag Resolution[2]: 8 ns or 0.1% (whichever is greater)
Max. Time Count Between States: 34 seconds
Max. State Tag Count: 4.29 X 10(9) states
Triggering
Sequencer Speed: 125 MHz, maximum
State Sequence Levels: 12
Timing Sequence Levels: 10
Max. Occurence Counter Values: 1,048,575
Pattern Recognizers: 10
Range Recognizers: 2
Range Width: 32 bits each
Timers: 2
Timer Value Range: 400 ns to 500 seconds
Glitch/Edge Recognizers: 2 (timing only)
Probes
Input Resistance: 100 kOhms, ±2%
Input Capacitance: ~8 pF
Min. Voltage Swing: 500 mV peak-to-peak
Threshold Range: ±6.0 V, adjustable in 50 mV increments
Environmental characteristics
Net Weight: 11.8 kg (26 lbs)
Size: 218 mm H x 440 mm W x 367 mm D
(8.6 x 17.3 x 14.5 in)
Warranty: 1 year
HP 1660CS 136-Channel 100 MHz State/500 MHz Timing Benchtop Logic Analyzer with 2-Channel Oscilloscope Opt 015 Ethernet LAN port Opt 0B1 Add manual set Opt 0B3 Service manual Opt 0BF Programming reference manuals Opt 1BP Mil std 45662A calibration w/ test data Opt 1CM Rackmount kit Opt AB0 Taiwan - Chinese localization Opt ABD Germany - German localization Opt ABE Spain - Spanish localization Opt ABF France - French localization Opt ABJ Japan - Japanese localization Opt ABZ Italy - Italian localization Opt UK9 Front panel cover Opt W30 3 Yrs of Customer Return Repair Service Opt W32 3 Yrs Customer Return Calibration Service Opt W34 3 Yrs Customer Return Stds Comp Cal Service Opt W50 5 Yrs of Customer Return Repair Service Opt W52 5 Yrs Customer Return Calibration Service Opt W54 5 Yrs Customer Return Stds Comp Cal Service
The HP1660C/CS/CP Series Benchtop Logic Analyzers
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
All orders include the following:
The 1660CS comes with an operating manual, mouse, and power cord.
Related product families available online:
Page Updated: Wednesday January 14 23:55:29 UTC 1998