HP CaLan 3010R Sweep/Ingress Analyzer![]()
|
Recent enhancements to this analyzer include dual path sweep, new digital measurements and an even faster sweep speed. Dual path sweep - one box for both forward and return sweep - makes the most efficient use of system bandwidth. It also saves both headend space and the cost of your test equipment. You can now quickly and easily measure the average power of digital carriers -- including return path TDMA (bursted) carriers. These measurements will assure you that your subscribers are receiving high-quality digital signals. And, now our industry leading sweep speed is even faster; measurements can be completed in just 650 milliseconds.
Sweep Characteristics
Sweep Source Amplitude Accuracy Output Range: +10 dBmV to +50 dBmV in 1 dB steps Absolute Accuracy: ± 1.5 dB Relative Accuracy: ± 0.5 dB Harmonic Output: <-30 dBc, 5 to 10 MHz; <-35 dBc, 10 to 1000 MHz Spurious Output: <-35 dBc Source Output Return Loss: >15 dB Source blanking during sweep: >60 dBc Sweep Receiver Characteristics: HP CaLan 3010B compatible with 3010H forward sweep transmitter Sweep Frequency Range: 5 MHz to 1 GHz Sweep Width: Continuously variable Frequency Resolution: 223 to 401 data points Minimum Sweep Time: 650 ms Sweep Tables: 4 user-definable tables for 350 carriers Data Transmission Pilot Characteristics Range: 5 MHz - 1 GHz Data Carrier Modulation Bandwidth: -30 dBc <750 kHz -50 dBc <1.8 MHz Proximity of Equal Amplitude CW Carrier without Communications Interruption <300 kHz Frequency Agile with 10 kHz Settability
Signal Level Meter
Digital Signal Power Levels Formats: QAM, QPR (DMX), QPSK and VSB Amplitude accuracy: ±1.5 dB (typical) Frequency Range: 5 MHz to 1 GHz Accuracy: ±25 kHz Resolution: 10 kHz Tuning Configuration: Standard, Off Air VHF/UHF, HRC, IRC, SECAM, PAL, and user defined IF Bandwidth: 230 kHz Video Bandwidth: 300 kHz, automatic 10 Hz in C/N Amplitude Accuracy for Sweep and Carrier Measurement Range: -45 to +70 dBmV Typical Accuracy: ±1.0 dB Calibrator: ±0.25 dB @ 113.36 MHz, ± 0.2MHz Frequency Flatness: ±0.5 dB Attenuator: ±0.5 dB Log Linearity: ±0.5 dB Resolution: 0.1 dB Input Impedance: 75 ohms Input Match: 0 dB attenuation >14 dB; all other settings >20 dB Hum Range: 0.5 to 5% Resolution: 0.1% Accuracy: ±0.2% ±30% of reading Carrier-to-Noise (with extended preselector) Range: 50 dB typical Accuracy: ±2 dB Repeatability: ±1 dB Fiber Power Meter Option (3010R only) Wavelength: 1310 and 1550 nm Measurement Range: -38 to +20 dBm @ 1310 nm; -38 to +18 dBm @ 1550 nm Resolution: 0.1 dB Accuracy: ±5% Display: dB, dBm, mW, mW, nW Connector Styles: ST, FC, biconic, D4, SMA, or bare fiber, rotary splice, RM
General Specifications
Size: 3.75 in W x 12.5 in H x 10.5 in D Weight: 10.7 lb with battery Power: +10 to + 15 Vdc @ 550 mA maximum Battery: 12 V (1.9 AH) rechargable lead acid Usage time: 4 hrs continuous; 8 hrs typical; Display Area: 5.00 in x 1.33 in Resolution: 240 x 64 pixels Type: LCD with EL backlight Temperature Operating: -20 to +50° C Storage: -20 to +70° C
HP CaLan 85962B 3010R Sweep/Ingress Analyzer Opt 030 Cable TV Data Management Software Opt 031 Cable TV Data Management Software plus FCC Reports Opt 052 Dual Path Sweep HP CaLan 85963B 3010H Sweep/Ingress Analyzer Opt 030 Cable TV Data Management Software Opt 031 Cable TV Data Management Software plus FCC Reports Opt 050 Forward Sweep Transmitter Opt 052 Dual Path Sweep
Available accessories for this product include:
HP CaLan Product Family, Product Overview
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related Information:
Related HP Cable TV Test Equipment product datasheets:
Page Updated: Thursday October 15 19:36:55 UTC 1998