The ideal companion to Hewlett-Packard's noise figure meters and systems is the HP 346 family of noise sources. Since they are broadband, they eliminate the necessity for several sources at different frequency bands. Each source has individually calibrated ENR values at specific frequencies. The calibration is printed on its label for easy loading into the HP 8970B. The low SWR of each noise source reduces a major source of measurement uncertainty reflections of test signals. In addition, the variety of available connectors reduces the need for degrading accuracy with connector adapters. The HP 346 family of noise sources are designed for a broad range of measurement applications. The HP 346C covers the broadest frequency range10 MHz to 26.5 GHz. The high ENR, low SWR, and variety of connectors makes the HP 346B a general-purpose noise source. The HP 346A is designed especially for accurate characterization of input impedance-sensitive devices such as GaAsFETs and UHF amplifiers. Its very small change in re flection coefficient (<0.01) from ON to OFF minimizes errors when measuring noise figure and gain as a function of input impedance.


This product family includes


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Range
HP 346 A/B:			10 MHz to 18 GHz
HP 346C:			10 MHz to 26.5 GHz

Excess Noise Ratio (ENR) Limits
HP 346A:			5 to 7 dB
HP 346B:			14 to 16 dB
HP 346C:
	10 MHz to 12 MHz:	12 to 16 dB
	12 to 26.5 GHz:		14 to 17 dB

Maximum SWR (reflection coefficient) On and Off
HP 346A/B
	10 to 30 MHz:		1.3 (0.13)
	30 to 5000 MHz		1.15 (0.07)
	5 to 18 GHz		1.25 (0.11)
HP 346C
	10 MHz to 18 GHz	1.25 (0.11)
	18 to 26.5 GHz		1.35 (0.15)

Power Required:			28 ±1 Vdc

Dimensions
Size:				21 mm W x l40 mm H x 30 mm D
				(0.8 in x 5.5 in x l.2 in)
Weight
	Net:			0.108 kg (3.5 oz)
	Shipping:		0.5 kg (1 lb)

Standard Connector:		APC 3.5 (male)

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 346A	Noise Source
   Opt 001	Type-N (male) Connector
   Opt 002	APC-7 Connector
   Opt 004	Type-N (female) Connector
   Opt 910	Extra Operating Manual
   Opt W30	Extended Repair Service
   Opt W32	Calibration Service
HP 346B	Noise Source
   Opt 001	Type-N (male) Connector
   Opt 002	APC-7 Connector
   Opt 004	Type-N (female) Connector
   Opt HO1	High ENR
   Opt H42	DBS Noise Source
   Opt 910	Extra Operating Manual
   Opt W30	Extended Repair Service
   Opt W32	Calibration Service
HP 346C	Noise Source
   Opt 910	Extra Operating Manual
   Opt W30	Extended Repair Service
   Opt W32	Calibration Service


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

Related product groups available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday February 05 04:51:12 UTC 1999