HP 3567A PC Spectrum/Network Analyzer![]()
|
The HP 3567A includes a source for stimulating circuits or systems. For fast measurement processing, a powerful hardware signal processor module converts time data to frequency domain data using the latest FFT technology. The included HP 35653C source module provides internal calibration signals and sine, noise, and pulse test stimulus.
An optional HP 35659A, SCSI interface module adds high speed transient capture, analysis, and playback capability (with HP 35656B). The optional HP 35656B, programmable DAC module also adds arbitrary waveform and chirp capability. The optional HP 35658A Tachometer/Trigger module improves order analysis.
Three optional software packages enhance the already complete measurement capability with Order Analysis, Swept-Sine, and Real-Time Octave analysis.
If portability is important, the 4 slot HP 35650B mainframe and a portable PC make very a cost effective multi-channel system.
See also the HP 3566A PC Spectrum/Network Analyzer.
Windows is a U.S. registered trademark of Microsoft Corp.
Available modules include:
Frequency
Measurement Range 64 µHz to 102.4 kHz Sample Rate (per channel) 262,144 samples/sec Spans 195 mHz to 102.4 kHz Frequency Resolution 25 lines to 3200 lines Maximum Real-Time 2 channels at 25.6 kHz Bandwidth (fast averaging, display off) Frequency Accuracy ± 8 ppm
Amplitude/Phase
Absolute Amplitude Accuracy (FFT) 0.15dB (A combination of Full Scale Accuracy, Full Scale Flatness, and Amplitude Linearity.) Cross-Channel Gain Accuracy: ± 0.1 dB (Frequency Response) Cross-Channel Phase Accuracy ± 0.5 deg
Dynamic Range
FFT Spurious Free Dynamic Range: 80 dB (85 dB typical) Input Noise Level(Flat Top Window, most sensitive range, Source Impedance = 50 Ohm) 20 Hz to 200 Hz: <565/sq.root(f) (frequency dependent) nVrms/sq.root(Hz) Above 200 Hz: <40nVrms/sq.root Hz (frequency independent)
Input
BNC Input range (full scale) 1.26 mVpk to 39.8 Vpk in 2 dB steps Maximum Input Levels: 42 Vpk IEPE Signal Conditioning Current Source: 4 mA Open Circuit Voltage: >20 Vdc Connections Grounded or Floating Coupling AC or DC AC coupling roll off <3dB at 1 Hz Input impedance 1 Mohm ± 5% Charge Gain (at 1 kHz) ± 0.3 dB Flatness (to 51.2 kHz) ± 0.1 dB Phase (to 51.2 kHz) ± 0.5°
Trigger
From Input channel Internal Positive or negative slope Trigger level resolution ± 0.031% of full scale range Maximum Trigger Delay Post Trigger: 0 to 104,575 samples Pre Trigger: 0 to 8,191 samples From HP 35658A (Tachometer/Trigger Module) External Trigger Range Range: -23 V to +23 V Resolution: <5V: 40 mV >5V: 200 mV Input impedance >20 kohms (typical)
Source/DAC Output
HP35653A/C Max output level 10 V Max Current 50 mA Max capacitive load 0.01 uF Min Frequency resolution 15.6 mHz Max Frequency 102.4 kHz (Hp 35653C) 51.2 kHz (HP 35653A) HP35658A (optional) Max Frequency Clock 131,072 Hz set in 2x steps Anti-Alias filter 200 Hz to 51.2 kHz in 200 Hz steps Amplitude Resolution 16 bits Harmonics -68 dBc (<2 kHz) Max DAC buffer 7.5 Msamples (with OPT 116)
Options
Computed Order Tracking - with HP 35636A software Amplitude Accuracy ± 1dB Phase accuracy RPM Range 1st order 2-5 order 10 to 10,000 ± 0.5° ± 1° 10,000 to 120K ± 1° Ramp rates 3,000 RPM/sec (4 input channels, 600-6000 RPM, delta order= .1, 30 RPM Step, 4 pulses/rev) Swept Sine Measurements - with HP 35657A software Dynamic Range: 132 dB Maximum number of points: 32,767 Real-Time Octave Analysis - with HP 35658A software International specification compliance ANSI S1.11-1986 Order 3, Type 1D IEC 225-1986 Accuracy Class 1 IEC 651 SLM Accuracy Type 1 DIN 45651 and others 1/3 Octave Frequency coverage On-line 100 mHz - 20 kHz Off-line 100 mHz - 80 kHz Frequency resolution 1/1, 1/3, 1/12 octave Dynamic range (ANSI S1.11-1986) 80 dB Amlitude accuracy ± 0.4 dB Band to band flatness ± 0.4 dB Linear Average range 31.25 mSec - 64,000 sec
Specification Abbreviations
dBVrms = dB relative to 1 Volt rms. dBfs = dB relative to full scale amplitude range. Full scale is approx. 2 dB below ADC overload. Typical = typical, non-warranted, performance specification included to provide general product information.
HP 3567A PC Spectrum/Network Analyzer Opt 005 Add l HP 35650A Mainframe (Includes HP 35650A Opt. 715, Mainframe Interconnect Cable Kit) Opt 010 Add l HP 35652B 1-Channel Input Module (maximum of 48 HP 35652B modules) Opt 116 Convert HP 35651C RAM to 16 MB Opt 054 Replace HP 35651C with 35654B DSP Module Opt 056 Add HP 35656B Programmable DAC Module (required for chirp, arb, and record/playback) Opt 050 Replace HP 35650A Mainframe with Portable, 4-slot, Non-expandable 35650B Opt 058 Add l HP 35658A Tachometer/Trigger Module Opt O59 Add HP 35659A SCSI Interface for External SCSI Disk (maximum is 1 HP 35659A) Opt 060 Add HP 35659A SCSI Interface with Internal 2 GB Disk (maximum is 1 HP 35659A) HP 35636A Order Tracking (optional software) HP 35637A Swept-Sine (optional software) HP 35638A Real-Time Octave (optional software) HP 35634A Software only for HP 3566A and 3567 (order only if you already have the hardware)
HP 3567A Includes One HP 35650A mainframe. Two HP 35652B 1-channel 102.4 kHz input module. One HP 35653C 102.4 kHz source module. One HP 35651C signal processor module with 4 Mbyte RAM. HP-IB cable, BNC breakout box and cable. 90 day warranty. HP 35634A time/frequency domain measurement software.
HP 3566A and HP 3567A Product Overview
( PDF)
HP 3566A and HP 3567A Techncial Specifications
( PDF)
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related product groups available online:
Page Updated: Friday February 12 00:51:18 UTC 1999