HP 5005B Signature Multimeter![]()
|
The HP 5005B includes capabilities for checking power supplies and circuit board integrity, universal counter features for measuring clock frequencies and time intervals between signals, and a means for verifying the analog integrity of active digital signals.
HP 5005B Unique Specifications Qualify Mode: Data clock qualified by external signal. DATA probe input impedance ~=50 kohm to the average value of "0" and "1" threshold settings (+/-6 V max); 15 pF. Front Panel Indicators: Flashing GATE light indicates detection of valid START, STOP, CLOCK conditions. Flashing UNSTABLE light indicates a difference between two successive signatures and possible intermittent faults. Logic Thresholds Preset thresholds: TTL, ECL, CMOS Adjustable thresholds: Each threshold can be adjusted to +/-12.5 V in 50 mV steps, accuracy is +/- .2V. Logic threshold circuitry: Operative during NORM, QUAL, kHz, TOTLZ and ms measurements. HP 5005B Multimeter Specifications Frequency Display: 5 digits Ranges: 100 kHz, 1 MHz, 10 MHz, 50 MHz, autoranged Resolution: 1 LSD (1 Hz on 100 kHz range) Accuracy: +/- 0.01% of reading +/- 1 count Minimum pulse width ~=10 ns in high or low state Gate time ~=1 s, fixed Input impedance ~=50 kohm to the average value of "0" and "1" threshold settings (+/-6 V max); 15 pF Totalizing Display: 5 digits Range: 0 to 99,999 counts Resolution: 1 count Maximum input frequency ~=50 MHz with a minimum pulse width of 10 ns and a minimum pulse separation of 10 ns Minimum START/STOP pulse width ~=20 ns DATA input impedance ~=50 kohm to the average value of "0" and "1" threshold settings (+6 V max); 15 pF START/STOP input impedance ~=100 kohm; 15 pF Time Interval Display: 5 digits Ranges: 10 ms, 100 ms, 1 s, 10 s, 100 s, autoranged Resolution: 1 count (100 ns on 10 ms range) Accuracy: +/-0.01% of reading +/-2 counts Minimum START/STOP pulse width ~20 ns START, STOP input impedance ~= 100 kohm Resistance Display: 4 or 5 digits, depending on range Ranges: 30 kohm, 300 kohm, 1 Mohm, 3 Mohm, 10 Mohm, autoranged Accuracy: (at 15 degrees C to 30 degrees C)
Display Range Full Scale Accuracy Resolution
30 kohm 29.999 kohm +/-1% of reading +/- 2 ohm 1 ohm 300 kohm 299.99 kohm +/-1% of reading 10 ohm 1 Mohm 999.9 kohm +/-1% of reading 100 ohm 3 Mohm 2999. kohm +/-10% of reading 1 kohm 10 Mohm 10000. kohm +/-10% of reading 10 kohm
Input impedance ~= 20 kohm to +/-2 V
DC Voltage: Display: 4-1/2 digits Ranges: +/-25 V, +/-250 V, autoranged; referenced to earth ground Accuracy: (at 15 degrees to 30 degrees C)
Range Accuracy Resolution
25 V +/-0.1% of reading +/-2 mV 1 mV 250 V (<100 V) +/-0.25% of reading +/-20 mV 10 mV 250 V (>=100 V) +/-0.25% of reading +/-20 mV 100 mV
Input impedance ~= 10 Mohm
Differential Voltage: Reading: Reads voltage at probe; displays difference between reading and voltage at the time delta-V key was depressed. Specifications: See DC voltage. Range is determined by the larger of the two compared voltages. Peak Voltage: Display: 3-1/2 digits Range: 0 - +/-12 Vp Resolution: 50 mV Accuracy: +/-2% of reading +/-5% of p-p signal +/- 100 mV Minimum peak duration ~= 10 ns Maximum time between peaks ~= 50 ms Input impedance ~= 100 kohm; 15 pF
HP 5005B Signature Multimeter Opt 910 One Additional Set of Manuals Opt W30 3 Yr. Return Repair Service Opt W32 3 Yrs Customer Return Calibration Service Opt W34 3 Yrs Customer Return Stds Comp Cal Serv Opt W50 5 Year Return Repair Service Opt W52 5 Yrs Customer Return Calibration Service Opt W54 5 Yrs Customer Return Stds Comp Cal Serv