HP 53310A Modulation Domain Analyzer![]()
|
In much the same way an oscilloscope provides insight into the dynamics of changing voltage, the HP 53310A provides insight into changes in frequency or time-interval measurements. You save time reviewing designs and locating problems. Use the HP 53310A to study frequency drift in electronic equipment; characterize jitter of digital communications systems, peripherals, and mechanical systems; determine frequency hopping performance of an agile transmitter, or measure cellular phone switching from cell to cell.
Frequency Measurements Range Channel A: 10 Hz to 200 MHz Channel B: 10 Hz to 100 MHz Channel C: 50 MHz to 2.5 GHz Maximum Measurement Rate Fast Histogram: 1.5 MHz Other Modes: 1 MHz Resolution: Maximum available measurement resolution or display resolution, whichever is greater Maximum Available Measurement Resolution (Auto Sampling): Refer to the HP 53310A Data Sheet. Display Resolution: vs Time, or Hisotgram of vs Time Window Off: Display Span/256 Window On: Display Span/224 Fast Histogram: Display Span/450 Accuracy: +/- (Resolution + (Frequency x Reference Error)) Time Interval Measurements +Time Interval Range: +20 ns to +1 second Maximum Measurement Rate: Fast Histogram: 2.5 MHz Other Modes: 1.25 MHz +/- Time Interval Range: -0.5 second to +0.5 second Maximum Measurement Rate: Fast Histogram: 2.0 MHz Other Modes: 1.25 MHz Resolution: Maximum available measurement resolution or display resolution, whichever is greater Maximum Available Measurement Resolution: Square root of ((200 ps rms*)^2 + (Threshold Trigger Errors)^2) *125 ps rms typical Note: 1. Threshold Trigger Errors are usually negligible for input slew rates > 5V/us. 2. Through averaging, Maximum Available Measurement Resolution can be significantly improved. Display Resolution: vs Time, or Histogram of vs Time Panorama Off: Display Span/256 Panorama On: Display Span/224 Fast Histogram: Display Span/450 Accuracy: +/- Resolution +/- (Time Interval x Reference Error) +/- Start Threshold Level Timing Error +/- Stop Threshold Level Timing Error +/- 1 ns Systematic Error Frequency Reference Standard Crystal Temperature Stability: < 8 x 10e-6, referenced to 25 degrees C Short Term Stability: < 4 x 10e-9 for 1 second average Aging Rate: < 3 x 10e-7/month Option 010 High Stability Oven Reference Temperature Stability: < 7 x 10e-9, referenced to 25 degrees C Short Term Stability: < 4 x 10e-11 for 1 second average Aging Rate: < 5 x 10e-10/day, < 1 x 10e-7/year Warm-up:Within 5 x 10e-9 of final value, 10 minutes after turn-on.(“Turn-off”, “turn-on”, and “off-time” apply to periods when power is disconnected from the HP 53310A rear panel.) When: 1. HP 53310A is operated in a 25 degrees C environment 2. Oscillator off time was less than 24 hours 3. Oscillator aging rate was < 5 x 10e-10 per day prior to turn-off
HP 53310A Modulation Domain Analyzer Opt 001 Extended Measurement Memory (4 X) Opt 010 High-Stability Oven Timebase Opt 030 2.5 GHz Channel C Opt 031 Digital RF Communications/ High Resolution 2.5 GHz Channel C Opt 305 Phase Analysis Software Opt 910 Additional set of User Manuals Opt 915 Additional Service Manual Opt 910 Additional set of User Manuals Opt W30 3 Year Return Repair Service Opt W32 3 Yr Calibration Customer Return Svc. Opt W34 3 Year Standards Compliant Cal Service Opt W50 5 Year Return Repair Service Opt W52 5 Year Cust Return Calibration Service Opt W54 5 Year Standards Compliant Cal Service
HP 5364A 2 to 18 GHz Microwave Mixer/Detector HP J06-59992A Time Interval Calibrator PN 5061-6175 Rack Mount Kit PN 1494-0015 Rack Mount Slide Kit
Related product families available online:
Page Updated: Thursday November 13 08:01:00 UTC 1997