HP 5518A Laser Head and Receiver

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 5518A Laser Head, used in HP interferometer systems, is similar in function to the more recently introduced HP 5519A Laser Head. It includes an internal measurement receiver, but it requires an external power supply. The HP 5518A is used primarily as the laser source in HP's 5528A Laser Measurement system. It can also be used in place of an HP 5519A Laser Head when upgrading an HP 5528A system to an HP 5529A Dynamic Calibrator. The HP 5518A has a laser beam diameter of 6 mm, and offers a vacuum wavelength accuracy of +/-0.1 ppm. The laser head uses a proven long-life laser tube with a demonstrated Mean Time Between Failure (MTBF) of greater than 50,000 hours of operation.

The HP 5518A is configured with appropriate optics and system electronics to build a laser interferometer system that meets the unique physical layout and measurement requirements of individual applications. The custom positioning system improves product quality, increases yields, and facilitates manufacture of precision products.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Physical Characteristics

Weight: 5.5 Kilograms (12 pounds)

Magnetic Field Strength (Non-Operating):
	Does not exceed 5.25 milligauss at a distance of 460 cm (15 ft) from
	any point on the surface of the packaged Laser Head.

Clearance Required for Cabling: 10.16 cm (4 in) beyond back

Power

Power Input Requirements:
	+15 Volts +/- -0.3 Volts at 25 Amperes maximum
	-15 Volts +/-0.l3 Volts at 0.02 Ampere maximum

Heat Dissipation: 
	23 watts during operation
	35 watts during warmup

Laser Beam Characteristics

Maximum Beam Power Output: 1 milliwatt

Minimum Beam Power Output: 180 microwatts

Beam Diameter: 6 millimeters (0.25 inch) typical

Vacuum Wavelength Accuracy (3 sigma, lifetime): 0.1 ppm

Vacuum Wavelength Stability:
	typical 1 hour:		0.002 ppm
	typical lifetime:	0.02 ppm

Nominal Vacuum Wavelength: 632.99137 nanometers

Outputs

Reference Frequency:
	1.7 to 2.4 MHz for HP 5518As with serial number 2532A02139 and above.
	1.5 to 2l.0 MHz for previous HP 5518As


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 5518A	Laser Head and Receiver
   Opt 1BN      MIL-STD 45662A Calibration
   Opt 1BP      MIL-STD 45662A Calibration with Test Data
   Opt AV4      User's manual
   Opt UK6      ISO 9001/2 Commercial Calibration Certification
		with Test Data
   Opt W30      3 Year Return Repair Service
   Opt W50      5-Year Return Repair Service

The HP 5518A can be used in a variety of laser-interferometer
positioning systems, including the HP 5528A Calibrator system.

The HP 5529U is an upgrade kit that includes products required to use
the HP 5518A as part of a 5529A Dynamic Calibrator system.
[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.

Page Updated: Thursday November 13 07:25:34 UTC 1997