HP 66101A dc Power Module![]()
|
Output ratings (at 40 deg C): 0-8 V, 0-16 A, 128 W Programming Accuracy (at 25 deg C +/- 5 deg C): 0.03% + 3 mV 0.03% + 6 mA Ripple and noise (20 Hz to 20 MHz): CV: 2 mV rms, 5 mV peak-to-peak; CC: 8 mA rms Readback accuracy: (via HP-IB or keyboard display at 25 deg C +/- 5 deg C): 0.02% + 2 mV, 0.02% + 6 mA Line regulation: 0.5 mV, 0.75 mA Load regulation: 1 mV, 0.2 mA Transient Response Time: Less than 1 ms for the output voltage to recover within 100 mV of its previous level following any step change in load current up to 10 percent of rated current. Supplemental Characteristics Average resolution: 2.4 mV, 4.6 mA, Output voltage programming: 50 mV OVP Accuracy: 250 mV Physical Specifications Weight: 2.8 kg (6 lb)
HP 66101A dc Power Module Opt 760 Open/Close and Polarity Reversal Relay Opt 910 Extra Manual Set: User's Guide, Programming Guide and Service ManualAccessories: HP 5060-3351 Field-Installable Relay Kit HP 5060-3386 Standard Connector Assembly HP 5060-3387 Standard Connector Assembly with installed relays HP 66000-90001 Mainframe Installation Guide HP 5959-3386 dc Power Module User's Guide HP 5959-3362 dc Power Module Programming Guide HP 66000-90003 Mainframe Service Manual HP 5959-3364 dc Power Module Service Manual HP 1252-1488 4-pin FLT/Inhibit Connector
All orders include the following:
Installation Guide
Customers outside the U.S. can also get local HP DIRECT help
Related HP 66000A Modular Power System product datasheets:
Related product families available online:
Page Updated: Thursday November 13 08:20:17 UTC 1997