HP 66106A dc Power Module![]()
|
Output ratings (at 40 deg C): 0-200 V, 0-0.75 A, 150 W Programming Accuracy (at 25 deg C +/- 5 deg C): 0.03% + 90 mV, 0.03% + 0.4 mA Ripple and noise (20 Hz to 20 MHz): CV: 30 mV rms, 50 mV peak-to-peak; CC: 1 mA rms Readback accuracy: (via HP-IB or keyboard display at 25 deg C +/- 5 deg C): 0.02% + 54 mV, 0.02% + 0.3 mA Line regulation: 5 mV, 30 uA Load regulation: 7 mV, 30 uA Transient response time: Less than 1 ms for the output voltage to recover within 100 mV of its pervious level following any step change in load current up to 10 percent of rated current Supplemental Characteristics Average Resolution: 60.0 mV, .23 mA, 1,25 mV output voltage programming 1.25 mV OVP Accuracy: 2.5 V Physical Specifications Weight: 2.8 kg (6 lb)
HP 66106A dc Power Module Opt 760 Open/Close and Polarity Reversal Relays Opt 910 Extra Manual SetAll orders include the following:Accessories: HP 5060-3351 Field-Installable Relay Kit HP 5060-3386 Standard Connector Assembly HP 5060-3387 Standard Connector Assembly with installed relays HP 66000-90001 Mainframe Installation Guide HP 5959-3386 dc Power Module User's Guide HP 5959-3362 dc Power Module Programming Guide HP 66000-90003 Mainframe Service Manual HP 5959-3364 dc Power Module Service Manual HP 1252-1488 4-pin FLT/Inhibit Connector
Installation Guide
No literature is available online at this time.
Customers outside the U.S. can obtain assistance through local HP DIRECT help.
Related Information:
Related HP 66000A Modular Power System product datasheets:
Related product families available online:
Page Updated: Friday February 12 02:00:44 UTC 1999