HP 6614C 50 Watt System DC Power Supply, 100V, 0.5 A

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The 6614C System DC Power Supply is an ideal power source for demanding production test applications. This dc power supply offers high performance and precision measurements in a one-box solution. To reduce test-system development time and provide precision testing, the 6614C provides current measurement down to the microamp level. The 6614C also provides high-speed programming with under 4 millisecond response time.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Specifications

Output Ratings: (0-55 deg C) 0-100 V, 0-0.5 A Programming Accuracy: (25 deg C ± 5 deg C) 50 mV + 0.05%, 0.5 mA + 0.05% Ripple and Noise: in the range of 20 Hz to 20 MHz, with outputs ungrounded or with either terminal grounded. Voltage (rms/p-p) Normal Mode: 0.5 mV/5 mV Current (rms): 1 mA DC Measurement Accuracy: via HP-IB or front panel meters with respect to actual output at 25 deg C ± 5 deg C Voltage: 12 mV + 0.03% Low current Range (-20 mA to +20 mA): 2.5 uA + 0.1% High current range (+20 mA to +rated I) 0.1 mA + 0.2% (-20 mA to -rated I) 0.7 mA + 0.2% Load Regulation: change in output voltage or current for any line change within ratings Voltage: 5 mV Current: 0.5 mA Line Regulation: Voltage: 1 mV Current: 0.25 mA Transient Response Time: Less than 100 us for the output voltage to recover to its previous level (within 0.1% of the voltage rating of the supply or 20 mV) following any step change in load current of up to 50% of the output current rating of the supply.

Supplemental Characteristics

Output Programming Range: The supply will accept these values shown even though these values exceed specified ratings. The supply will generate an error message when programmed above these values. Voltage: 102.38 V Current: 0.5118 A OVP: 110 V Average Programming Resolution: Voltage: 25 mV Current: 0.125 mA OVP: 500 mV OVP Accuracy: 1.2 V +2.4% Maximum Current Measurement: 0.70 A Average Current Measurement Resolution: High range: 21 uA Low range: 0.6 uA Sink Current: 0.3 A DC Floating Voltage: Output terminals can be floated up to 240 Vdc maximum from chassis ground. Remote Sensing: Up to 2 volts can be dropped in each load lead. Add 2 mV to the voltage load regulation specification for each 1 volt change (in the positive output lead) due to load current change. Command Processing Time: Average time required for the output voltage to begin to change following receipt of digital data is 4 ms for power supplies connected directly to the HP-IB. Output Programming Response Time: The rise and fall time (10/90% and 90/10%) of the output voltage is less then 2 ms. The output voltage change settles within 1 LSB (0.025% X rated voltage) of final value in less than 6 ms. Measurement Time: Average time to make a voltage or current measurement is 50 ms. HP-IB Interface Capabilities: SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, E1 and CO. IEEE 488.2, SCPI command set and HP 6630A Series programming compatibility. AC Input: 104 to 127 Vac, 47 to 63 Hz, 1.4 A Input Power: (full load) 160 VA, 100 W Regulatory Compliance: Listed to UL 3111-1, certified to CSA C22.2 no. 1010.1-92; conforms to EN61010; conforms to IEC 1010-1, complies with European EMC and Low Voltage directives, carries the CE mark. Recommended Calibration Interval: one year Warranty Period: three years

Physical Specifications

Weight: 8.2kg (18 lb) net 10.6 kg (23.5 lb) net shipping Size: 88.1 mm H x 212.8 mm W x 348.3 mm D (3.5 in x 8.4 in x 13.7 in )


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 6614C      50 Watt System DC Power Supply
   Opt 760    Isolation and Reversal Relays
   Opt 1CM    Rack Mount Kit, HP p/n 5062-3972
   Opt AXS    Rack mount kit for side by side mounting
              (HP p/n 5061-9694 lock-link kit and
              HP p/n 5062-3974 flange kit)
   Opt 0BN    Service Manual and extra Operating Guide
   Opt 0B0    Delete manual kit

AC Line Voltage Options
   Opt 100    87 to 106 Vac, 47 to 63 Hz, 1.6 A
   Opt 220   191 to 233 Vac, 47 to 63 Hz, 0.8 A
   Opt 230   207 to 253 Vac, 47 to 63 Hz, 0.75 A


Accessories: HP p/n 5062-3996 and p/n 1494-0015 (previously option AXU) Rack mount and slide for side-by-side mounting of two different depth instruments. HP p/n 1494-0015, 5062-3996, and 5062-4022 (previously option AXV) Rack mount, slide and single support shelf for mounting one HP 6610 series instruments. Support rails are required when rack mounting with Opt 1CM and Opt AXS. Use HP E3663A support rails for HP rack cabinets. Use chassis equipment support angles such as E3664A for non-HP rack cabinets.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

All orders include the following:


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related Information:


Related HP 6610C/HP 6630B Series Precision Measurement Single-Output System DC Power Supplies product datasheets:



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.

Page Updated: Wednesday December 10 22:44:09 UTC 1997