HP 6843A Harmonic/Flicker Test System![]()
|
An interactive demonstration of HP's 6840 Series Harmonic/Flicker Test System is available for you to download.
Recommended system requirements for this demonstration are:
Output ratings: Power: 4800 VA rms voltage range: 0-300 V range Maximum rms current: 16 A Measurement accuracy (25 deg C +/-5 deg C): Current magnitude (low range) Fundamental: 0.03% + 1.5 mA Harmonics 2-49: 0.03% + 1 mA + 0.2%/kHz Current Magnitude (high range) Fundamental: 0.05% + 5 mA Harmonics 2-49: 0.05% + 3 mA + 0.2%/kHz Flicker: Compliant with IEC 868 Flicker perceptibility (pst): Compliant with IEC 868 Synchronixation accuracy: <1 ppm Current shunt burden: 1.5 seconds Load regulation: 0.5% of full scale Line regulation: 0.3% of full scale Physical Specifications Weight: 87.7 kg (193 lb) Dimensions: 425.5 mm W x 266.7 mm H x 602 mm D (16.75 in x 10.5 in x 23.7 in)
HP 6843A Single-phase AC Power Source/Analyzer Opt 1CM Rack Mount Kit (HP 5062-3977) Support rails required HP E3664A cabinet rails must be ordered with Opt 1CM for rack mounting the HP 6843A Opt 400 360-440 Vac L-L, 48 to 63 Hz operation Opt 0BN Extra Documentation Accessories HP 5063-2310 Heavy duty rack slide kitHP 5063-2310 Heavy duty rack slide kit
All orders include the following:
Graphical User Interface
Trademarks:
Microsoft is a U.S. registered trademark of Microsoft Corporation. Windows is a U.S. registered trademark of Microsoft Corporation.
Customers outside the U.S. can also get local HP DIRECT help
Related HP 6840 Series Harmonic/Flicker Test Systems product datasheets:
Related product families available online:
Page Updated: Thursday November 13 08:17:13 UTC 1997