HP 70301A Microwave Tracking Generator, 2.7 GHz to 18 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
An HP 70301A microwave tracking generator adds stimulus-response measurement to an HP 70000 series spectrum analyzer, enabling accurate characterization of gain, frequency response, isolation, and return loss. The wide dynamic range (>130 dB with 70301A and 71210C) makes accurate measurements of filter rejection and switch isolation without the need for time-consuming averaging. The system has very high selectivity, with resolution bandwidths as narrow as 10 Hz. High selectivity allows measurements in the presence of other signals -- a key advantage when measuring LO-to-RF isolation of a mixer or the return loss of an active antenna system. Unlike a point-by-point measurement system, the HP 70000 scalar system sweeps quickly and provides continuous data. The system is controlled using HP 70871A scalar personality.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Specifications

Range:				2.7 to 18 GHz

Accuracy (<= 1 0 MHz synthesized span):	
				±[(freq x ref¹) + 1% span + 15 Hz]
Tracking Drift:			<3 Hz/hr	
Tracking Adjust Range:		±500 Hz in 1 Hz steps 
Offset Range:			±5 MHz w/ext 21.4 MHz


¹Frequency reference accuracy: 	±1.3 x 10e-5 per year standard, 
				±5.0 x 10e-10 per day with HP 70310A

Power Specifications

Maximum Leveled Power:		-2 dBm, (0 dBm 20 to 30°C)
Amplitude Control Range:	+14 to -66 dBm
Vernier Range:			11 dB (0.1 dB resolution)
Amplitude Accuracy (20 to 30°C)
	Absolute:		±0.5 dB @ 2.7 GHz			
	Flatness:		±1.0 dB
	Incremental:		±0.15 dB/dB, ±0.8 dB total
	Total absolute accuracy:±2.3 dB
	Amplitude drift (characteristic):
				< ±0.05 dB/°C @ -2 dBm
Output Attenuator Range:	55 dB in 5-dB steps
	Repeatability:		<= ±0.2 dB for any setting

Spectral Purity

Noise Sidebands @ -2 dBm, 6 GHz (10 kHz):
				< -90 dBc/Hz (characteristic)
Sidebands:			< -70 dBc (characteristic)	
Spurious (max leveled power)
	Harmonics	
		2nd:  		< -7 dBc (< -15 dBc typical)
		3rd:  		< -11 dBc (< -15 dBc typical)		
	Non-harmonic:		< -60 dBc 
	Sub-harmonic:		none
RF Off Residuals:		< -120 dBm tracking
				< -65 dBm LO emissions

Temperature Operating: 0 to 5°C Storage: -40 to +75°C

System Specifications

For the HP 71209A Spectrum Analyzer (preselected) 
with the HP 70300A and 70301A Tracking Generators

Signal Frequency Range:		50 kHz to 22 GHz
Scalar Frequency Range
	with HP 70300A:		50 kHz to 2.9 GHz
	with HP 70301A:		2.7 to 18 GHz
Scalar Dynamic Range 
	at 2.0 GHz:		>128 dB
	at 10 GHz:		>130 dB
	at 18 GHz:		>130 dB

Tracking Generator Feedthrough (dBm in 10 Hz BW)
	at 2.0 GHz:		< 138 dBm 
	at 10 GHz:		< 130 dBm 
	at 18 GHz:		< 130 dBm 


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 70301A	Microwave Tracking Generator, 2.7 GHz to 18 GHz
   Opt 001	Delete 55 dB Input Attenuator
   Opt 098	CPU and RAM/ROM Upgrade (HP 80680A)¹
   Opt 099	RAM/ROM Upgrade (HP 80681A)¹
   Opt 1BN	Certificate of Calibration
   Opt 1BP	Certificate of Calibration and Data
   Opt 871	Scalar Personality
   Opt 910	Extra User's Manual
   Opt 915	Service Manual Set
   Opt W30      3 Year Return Repair Service
   Opt W32      3 Year Calibration Customer Return Service
   Opt W34      3 Year Standards Compliant Calibration Service
   Opt W50      5 Year Return Repair Service
   Opt W52      5 Year Customer Return Calibration Service
   Opt W54      5 Year Standards Compliant Calibration Service



¹If this module will be installed into an existing system, a firmware
upgrade may be required. Modules with firmware version B.04.02 (920325)
and earlier require upgrade HP 70860A. Modules with later
version firmware may use upgrade HP 70861A. For more information
see service note 70900A-14L / 70900B-01G.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.

Page Updated: Wednesday January 07 23:19:50 UTC 1998