HP 71209A Microwave Spectrum Analyzer, 100 Hz to 26.5 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 71209A microwave spectrum analyzer provides full sweep from 100 Hz to 26.5 GHz, plus built-in external mixer capability. Its superb frequency accuracy, amplitude accuracy, and repeatability let you perform even the most demanding satellite tests.

As part of the Modular Measurement System (MMS) family, you can choose a configuration that best meets your requirements in performance, size, and price. Adding accessories such as a preamplifier or tracking generator is very easy.

For automated testing, the HP 70000 series of spectrum analyzers are compatible with the HP 8566B. Their proven reliability and repeatability allow a three-year calibration cycle, giving you a very low lifetime cost.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Specifications

Frequency Range: 100 Hz to 26.5 GHz Tunable in 1 Hz increments Frequency Readout Accuracy Span <=10 MHz x N1: ±[(freq readout x freq ref accuracy) +1.0% of span +10 Hz] Span >10 MHz x N1 Sweep >= 20 ms: ±[(freq readout x freq ref accuracy) +1.5% of span +10 Hz] 10 ms <= sweep <20 ms ±[(freq readout x freq ref accuracy) +2.5% of span +10 Hz] Frequency Span Range: 0 to 26.5 GHz in 0.5% increments Accuracy Span <=10 MHz x N1: ±[1% of span+ (span x freq ref accuracy)] Span >10 MHz x N1 Sweep >=50 ms: ±[1.5% of span+(span x freq ref acc)] Sweep >=20 ms: ±[2.5% of span+(span x freq ref acc)] Sweep >=10 ms: ±[4.0% of span+(span x freq ref acc)] Frequency Reference Accuracy w/ HP 70310A w/o HP 70310A Aging: <1 x 10-7/year, <3 x 10-6/year <5 x 10-10/day (7-day avg.) Temperature Drift: <7 x 10-9 <1x10-5 Sweep Time Range (continuous): 10 ms to 1000 s with HP 70700A: Swept freq spans: 15 ms to 355 s Fixed freq (zero span): 80 µs to 355 s with 800 point trace Resolution Bandwidth (3 dB, synchronously tuned) Range: 10 Hz to 300 kHz (HP 70902A) 100 kHz to 3 MHz (HP 70903A) (1, 3, 10 sequence and 10% increments except 3 kHz to 10 kHz) Accuracy: ±20% Video Bandwidth Range: 3 Hz to 300 kHz (HP 70902A) (1, 3, 10 sequence) 300 Hz to 3 MHz (HP 70903A) Accuracy: ±20% (characteristic)

Amplitude Specifications

Frequency Response (10 dB attn, preselector peaked) 0 to 55 °C 20 to 30 °C 0 to 55 °C Frequency Peak Ref. to Ref. to Range Variation Calibrator Calibrator 100 Hz to 2.9 GHz: ±1.5 dB ±2.0 dB ±2.0 dB 2.7 to 6.2 GHz: ±2.0 dB ±2.0 dB ±3.0 dB 6.0 to 12.8 GHz: ±2.0 dB ±2.0 dB ±3.0 dB 12.6 to 22.0 GHz: ±2.0 dB ±2.0 dB ±3.5 dB 22.0 to 26.5 GHz: ±2.5 dB ±2.5 dB ±4.0 dB Ref. to (10 dB attn, Calibrator 20-30 °C, preset: 2.7 to 22.0 GHz + 2.0, to 3.0 dB preselector DAC): 22.0 to 26.5 GHz + 2.5, to 3.5 dB (for spans <=100 MHz) Calibrator Uncertainty: ±0.3 dB (-10 dBm, 300 MHz) Input Attenuator Range: 0 to 65 dB range in 5 dB steps Switching Repeatability: ±0.2 dB Accuracy Center Frequency Referenced to the 10 dB setting 0.0 to 2.9 GHz ±1.2 dB 2.9 to 12.7 GHz ±2.3 dB 12.7 to 19.9 GHz ±2.8 dB 19.9 to 26.5 GHz ±4.8 dB IF Gain Accuracy Gain 20 to 30 °C 0 to 50 °C HP 70902A 10 dB ±0.2 dB ±0.2 dB 20 dB ±0.2 dB ±0.2 dB 30 dB ±0.2 dB ±0.3 dB 40 dB ±0.2 dB ±0.5 dB 50 dB ±0.2 dB ±0.6 dB 60 dB ±0.4 dB ±0.8 dB HP 70903A 10 dB ±0.1 dB 20 dB ±0.3 dB Scale Fidelity Bandwidth Fidelity Log Corrected HP 70902A: 10 Hz ±0.7 dB (0 to 90 dB): 30 Hz to 100 kHz ±0.5 dB HP 70903A: 300 kHz to 1 MHz ±0.5 dB (0 to 75 dB): 3 MHz ±0.7 dB Resolution Bandwidth Switching Repeatability: ±0.2 dB in 1,3,10 sequence Marker Resolution: ±0.03 dB

Noise

Spectral Purity Noise Sideband (dBc/Hz) (characteristic) Offset N=1 N=2 N=4 100 Hz -92 -86 -80 300 Hz -100 -94 -88 1kHz -108 -102 -96 3 kHz -108 -102 -96 10 kHz (spec)<-108 <-102 <-96 30 kHz -112 -106 -100 100 kHz -115 -109 -103 300 kHz -123 -117 -111 1 MHz -135 -129 -123 3 MHz -145 -139 -133 10 MHz -153 -147 -141 Line and System Related Sidebands: <-65 dBc +20 Log N1 Displayed Average Noise Level Frequency DANL (characteristic below 10 MHz) 10 Hz Res BW, 0 dB: 100 Hz <-92 dBm (char) attn. 3 Hz Video BW: 300 Hz <-95 dBm (char) Ref Level <=-75 dBm: 1 kHz <-101 dBm (char) 3 kHz <-111 dBm (char) 10 kHz <-118 dBm (char) 30 kHz <-118 dBm (char) 100 kHz <-122 dBm (char) 300 kHz <-130 dBm (char) 1 MHz <-139 dBm (char) 3 MHz <-139 dBm (char) 10 MHz to 2.0 GHz -138 dBm 2.0 to 12.8 GHz -137 dBm 12.8 to 22.0 GHz -130 dBm 22.0 to 26.5 GHz -128 dBm with HP 70620B: 1.0 to 12.8 GHz -155 dBm 12.6 to 22 GHz -150 dBm 22.0 to 26.5 GHz -148 dBm

False Signals

Spurious Responses Input Response 100 Hz to 10 MHz <-60 dBc 10 MHz to 22 GHz <-70 dBc (Preselector ON for HP 70910A) Second Harmonic Distortion (Preselector ON for HP 70910A) Frequency Reponse 100 Hz to 20 MHz <-60 dBc 20 MHz to 2.9 GHz <-75 dBc 2.9 GHz to 26.5 GHz <-100 dBc Third-Order Intermodulation (20 to 30 °C) HP 70902A Center Intermod. Equiv. Frequency Products TOI 100 Hz to 20 MHz <-64 dBc +2 dBm 22 MHz to 2.9 GHz <-78 dBc +9 dBm 2.7 to 6.2 GHz <-68 dBc +4 dBm 6.0 to 26.5 GHz <-64 dBc +2 dBm HP 70903A Center Intermod. Equiv. TOI 100 Hz to 20 MHz <-54 dBc +2 dBm 22 MHz to 2.9 GHz <-68 dBc +9 dBm 2.7 to 6.2 GHz <-58 dBc +4 dBm 6.0 to 26.5 GHz <-54 dBc +2 dBm Image Responses For RF input Levels: <=0 dBm, 10 dB attn 6 MHz and 42.8 MHz: <-85 dBc 642.8 MHz Center Frequency Rejection 100 kHz to 2.9 GHz -85 dBc 2.7 to 6.2 GHz -70 6.0 to 12.8 GHz -70 12.7 to 18.0 GHz -70 18.0 to 26.5 GHz -60 Residual Responses (0 dB attn, Range Responses input terminated): 10 MHz to 26.5 GHz <-100 dBm Multiple and Out of Band Responses For Inputs: <= 26.5 GHz, <-70 dBc and RF levels: <=0 dBm, 310 dB attn

Declarations of Conformity


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 71209A     Microwave Spectrum Analyzer, 100 Hz to 26.5 GHz
   Opt 001    Substitute HP 70910A wide bandwidth RF section for the HP 70909A.
   Opt 006    Delete HP 70902A 10 Hz to 300 kHz BW IF section
   Opt 007    Delete HP 70903A 100 kHz to 3 MHz BW IF section
   Opt 110    Delete HP 70310A precision frequency reference
   Opt 121    Add distribution amplifier to HP 70310A
   Opt 122    Delete ovenized oscillator from HP 70310A
   Opt Z40    Single-connector, 100 Hz to 40 GHz operation

Rack Mounting Options
   Opt 810    Slide kit for both HP 70001A mainframe and HP 70004A display/mainframe
   Opt 908    Flange kit to mount without handles
   Opt 913    Flange kit to mount with handles

HP 70620B preamplifier for better sensitivity (1 GHz to 26.5 GHz) HP 70620B option 001 preamp (100 kHz to 26.5 GHz) HP 70300A RF tracking generator (20 Hz to 2.9 GHz) HP 70301A microwave tracking generator (2.7 GHz to 18 GHz)

All orders include the following:

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


Related MMS Spectrum Analyzer Family product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday February 18 07:51:14 UTC 1999