HP 71400C Lightwave Signal Analyzer![]()
|
The HP 71400C lightwave signal analyzer combines HP's high-performance microwave and RF spectrum analyzers with a sensitive wide-bandwidth optical receiver module, producing calibrated instrumentation for characterizing semi-conductor lasers, laser transmitters, optical modulators, and detectors.
Featuring bandwidths from 100 kHz to 22 GHz and wavelength operation from 1200 to 1600 nm or, with Option 850, from 750 to 870 nm, the HP 71400C easily and accurately charaterizes lasers and devices for modulation capability. It can make measurements of relative intensity noise (RIN), linewidth, and modulation performance with analog or digital format on a single-mode optical fiber.
The HP 71400C is part of the modular measurement system (MMS). This system provides an easy way to add additional capability to your lightwave signal analyzer such as; optical spectrum analyzer modules and tracking generator modules.
Wavelength Range Standard Option 850 1200 to 1600 nm 750 to 870 nm Frequency Range 100 kHz to 22 GHz Average Power Accuracy Factory-calibrated: ± 0.65 dB ± 5.0 nW ±connector variation [1] (at 1300 and 1550 nm std, User-calibrated: ± 0.05 dB ± 5.0 nW ±power meter accuracy or at 830 nm for Opt. 850) (by external power meter) [2] Modulated Power (20° to 30°C) Amplitude Accuracy at 100 MHz ± 1.0 dB Frequency Response relative to 100 MHz 100 kHz to 2.9 GHz ± 1.0 dB 2.9 to 22 GHz ± 1.0 dB Displayed Average Optical Noise Level (10 Hz RBW, 3 Hz VBW) Ref. Level <= -40 dBm Standard Option 850 10 MHz to 100 MHz -62 dBm -58 dBm 100 MHz to 16 GHz -66 dBm -62 dBm Harmonic Distortion 10 MHz to 22 or 2.9 GHz with modulated input optical power <=-30 dBm 70 dB below fundamental RF Input Frequency Response [3] 100 kHz to 2.9 GHz ± 2.3 dB (electrical) 2.9 GHz to 22 GHz ± 2.8 dB (electrical) Input Return Loss (with HMS-10/HP) Internal <40 dB Total <35 dB Maximum Input Power (with 30 dB Atten.) Average power +15 dBm Modulated power +15 dBm Input Connectors Single-mode fiber connectors: Diamond HMS-10/HP, FC/PC, ST, DIN, Biconic, SC [1] Connector reflections and losses vary with factors such as connector type, quality, cleanliness, temperature,
damage, wear. [2] Applies to any wavelength with average power readout set to match external calibrated optical power meter.
Does not include VSWR losses. [3] Assumes extended system calibration(Opt. 020). Otherwise, use module specifications for frequency response.
HP 71400C Lightwave Signal Analyzer, 100 kHz to 22 GHz Opt 001 Add HP 11980A Mach-Zehnder interferometer, fiber-optic Opt 006 100 kHz to 3 MHz resolution bandwidths Opt 007 10 Hz to 300 kHz resolution bandwidths Opt 011 Diamond HMS-10 / HP connector interface Opt 012 FC/PC connector interface Opt 013 DIN 47256 connector interface Opt 014 ST connector interface Opt 015 Biconic connector interface Opt 110 ±13 kHz/GHz/year frequency accuracy Opt 121 Add distribution amplifier to HP 70310A Opt 122 Delete ovenized oscillator in HP 70310A Opt 200 Delete HP 70004A mainframe/color display Opt 850 Operate 750 to 870 nm
Available accessories for this product include:
HP 71400C and 71401C Lightwave Signal Analyzers
( PDF)
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related product families available online:
Page Updated: Thursday February 18 09:24:37 UTC 1999