The following specifications apply when the HP 83201B is operating with
an HP 8920B.  See HP 8920DT product information for specifications that
apply when the HP 83201B is operating in the HP 8920DT system.

Signal Generator Specifications


Frequency Range:
	250 kHz to 1 GHz
Output Level Accuracy RF In/Out Connector:
	+/- 1.2 dB (level greater than or equal to -127 dBm)
Output Level Accuracy Duplex Out Connector:
        +/- 1.0 dB (-127 to +7 dBm)
Output Level Range: 
	-137 to -19 dBm into 50 ohms (std, other options available)
Reverse Power:
	60 watts continuous, 100 watts for 10 seconds/minute
Harmonics:
        <- 30 dBc
Non Harmonic Spurious:
       <- 60 dBc
        (at > 5 kHz from carrier) 

Optional TDMA Signal Generator Specifications

Frequency Range: 824 MHz to 894 MHz Output Level Range: RF In/Out: -22 dBm to -127 dBm Duplex Out: +4 dBm to -127 dBm Residual Error Vector Magnitude: <3.0% Residual Phase Error: < 2.6 degrees Residual Magnitude Error: < 2.6% IQ Origin Offset: <-30 dBc within 15 degrees C of last calibration Frequency Error: +/- 4 Hz plus reference error

Audio Source Specifications

Frequency Range: dc to 25 kHz Frequency Accuracy: 0.025% of setting Output Range: 0.1 mV to 4 Vrms Output Accuracy: +/- 2% of setting plus resolution

RF Analyzer Specifications

Frequency Measurement Range: 400 kHz to 1 GHz Level Measurement Range RF In/Out:(std, other options available) 1 mW to 60W continuous 100W for 10 seconds/minute Level Measurement Range ANT IN: -36 dBm to +20 dBm in auto-tune mode Frequency Measurement Accuracy: +/- 1 Hz plus timebase accuracy Power Measurement Accuracy: +/- 5% of reading +/- 0.01 mW for temperature range of 25 +/- 10 degrees C

Optional TDMA Analyzer Specifications

Frequency Range: 824 MHz to 894 MHz Input Level Range: RF In/Out: 1 mW to 60W (0 to +47.8 dBm) Antenna In: -36 to +17 dBm Residual Error Vector Magnitude: < 1.3% Error Vector Magnitude Measurement Accuracy: +/- 0.4% plus 2% of reading I/Q Origin Offset Accuracy: +/- 0.5 dB for values to -40 dBc Frequency Error Accuracy: +/- 2.5 Hz plus reference accuracy

AF Analyzer Specifications

Frequency Measurement Range: 20 Hz to 400 kHz Frequency Measurement Accuracy: +/- 0.02% plus resolution plus reference accuracy AC Voltage Measurement Range: 0 to 30 Vrms AC Voltage Measurement Accuracy: +/- 3% of reading (20 Hz to 15 kHz, inputs >/= 1 mV) DC Voltage Measurement Range: 100 mV to 42 V DC Voltage Measurement Accuracy: +/- 1.0% of reading plus DC offset Variable Frequency Notch Filter: Frequency Range: 300 Hz to 10 kHz

Spectrum Analyzer Specifications (Option 102)

Frequency Range: 400 kHz to 1 GHz Frequency Span/Resolution Bandwidth (coupled) Span Bandwidth <50 kHz 300 Hz <200 kHz 1 kHz <1.5 MHz 3 kHz <18 MHz 30 kHz >/= 18 MHz 300 kHz Plus full span capability Display: Log 1,2,and 10 dB/div Display Range: 80 dB Reference Level Range: +50 to -50 dBm


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 83201B	TDMA Cellular Adapter
   Opt 001      PDC Test format (HP 8920DT)
   Opt 002      PHS Test format (HP 8920DT)
   Opt 003      NADC Test format (HP 8920B)
   Opt 004      PDC and PHS Test format (HP 8920DT)


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


Related HP 8920DT Digital RF Communication Test System product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Monday October 05 19:44:46 UTC 1998