The following specifications apply when the HP 83201B is operating with an HP 8920B. See HP 8920DT product information for specifications that apply when the HP 83201B is operating in the HP 8920DT system.
Signal Generator Specifications
Frequency Range: 250 kHz to 1 GHz Output Level Accuracy RF In/Out Connector: +/- 1.2 dB (level greater than or equal to -127 dBm) Output Level Accuracy Duplex Out Connector: +/- 1.0 dB (-127 to +7 dBm) Output Level Range: -137 to -19 dBm into 50 ohms (std, other options available) Reverse Power: 60 watts continuous, 100 watts for 10 seconds/minute Harmonics: <- 30 dBc Non Harmonic Spurious: <- 60 dBc (at > 5 kHz from carrier)
Optional TDMA Signal Generator Specifications
Frequency Range: 824 MHz to 894 MHz Output Level Range: RF In/Out: -22 dBm to -127 dBm Duplex Out: +4 dBm to -127 dBm Residual Error Vector Magnitude: <3.0% Residual Phase Error: < 2.6 degrees Residual Magnitude Error: < 2.6% IQ Origin Offset: <-30 dBc within 15 degrees C of last calibration Frequency Error: +/- 4 Hz plus reference error
Audio Source Specifications
Frequency Range: dc to 25 kHz Frequency Accuracy: 0.025% of setting Output Range: 0.1 mV to 4 Vrms Output Accuracy: +/- 2% of setting plus resolution
RF Analyzer Specifications
Frequency Measurement Range: 400 kHz to 1 GHz Level Measurement Range RF In/Out:(std, other options available) 1 mW to 60W continuous 100W for 10 seconds/minute Level Measurement Range ANT IN: -36 dBm to +20 dBm in auto-tune mode Frequency Measurement Accuracy: +/- 1 Hz plus timebase accuracy Power Measurement Accuracy: +/- 5% of reading +/- 0.01 mW for temperature range of 25 +/- 10 degrees C
Optional TDMA Analyzer Specifications
Frequency Range: 824 MHz to 894 MHz Input Level Range: RF In/Out: 1 mW to 60W (0 to +47.8 dBm) Antenna In: -36 to +17 dBm Residual Error Vector Magnitude: < 1.3% Error Vector Magnitude Measurement Accuracy: +/- 0.4% plus 2% of reading I/Q Origin Offset Accuracy: +/- 0.5 dB for values to -40 dBc Frequency Error Accuracy: +/- 2.5 Hz plus reference accuracy
AF Analyzer Specifications
Frequency Measurement Range: 20 Hz to 400 kHz Frequency Measurement Accuracy: +/- 0.02% plus resolution plus reference accuracy AC Voltage Measurement Range: 0 to 30 Vrms AC Voltage Measurement Accuracy: +/- 3% of reading (20 Hz to 15 kHz, inputs >/= 1 mV) DC Voltage Measurement Range: 100 mV to 42 V DC Voltage Measurement Accuracy: +/- 1.0% of reading plus DC offset Variable Frequency Notch Filter: Frequency Range: 300 Hz to 10 kHz
Spectrum Analyzer Specifications (Option 102)
Frequency Range: 400 kHz to 1 GHz Frequency Span/Resolution Bandwidth (coupled) Span Bandwidth <50 kHz 300 Hz <200 kHz 1 kHz <1.5 MHz 3 kHz <18 MHz 30 kHz >/= 18 MHz 300 kHz Plus full span capability Display: Log 1,2,and 10 dB/div Display Range: 80 dB Reference Level Range: +50 to -50 dBm