HP 83205A CDMA/CDPD Cellular Adapter

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 83205A CDMA/CDPD Cellular Adapter adds optional CDMA and/or CDPD measurement capability to the HP 8921A for IS-95A/97 CDMA base station testing and/or CDPD Mobile Data Base Station (MDBS) testing. The HP 8921A retains its full capability for testing the analog performance of dual-mode CDMA base stations.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

The following CDMA specifications apply when the HP 83205A 
Option 001 or 003 is operating with an HP 8921A:

CDMA Signal Generator

Frequency Range: 824 to 894 MHz (usable from 800 MHz to 1000 MHz and from 4 MHz to 200 MHz with degraded rho and carrier feedthrough performance) Output Level Range: RF In/Out: -19 to -137 dBm Duplex Out: +4 to -127 dBm Output Level Accuracy: RF In/Out: +/-2.0 dB Typically +/-1.0 dB Duplex Out: +/-1.7 dB typically +/-1.0 dB Residual rho: better than 0.96, typically > 0.98 Reverse Link Source Modulation: OQSPK per TIA IS-95 Reverse Link Source Modulation Data: internal data buffer, Idle (all zeroes) PN Offset: Adjustable from 0 to 511 units (1 unit = 64 chips) Data Buffer: Size/length: 5400 frames Modes: Single, Continuous Looping, and Idle Input Data Rate: 9600 bps; 14,400 bps

CDMA Analyzer

Waveform Quality Measurement(rho) IS-95 forward or reverse link formats (QPSK or OQPSK) Input Frequency Range: 4 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Rho Measurement Range: 0.5 to 1.00 Rho Measurement Accuracy: < +/-0.005 Frequency Error Measurement Accuracy: +/-30 Hz using a measurement interval >/= 0.5 ms Average Power Measurement Input Frequency Range: 30 MHz to 1000 MHz Measurement Range: 1 mW to 60 W (0 to +48 dBm) Measurement Accuracy: +/-5% +/-1 uW, at 25 degrees C +/-10 degrees C +/-10% +/-1 uW, from 0 degrees to 55 degrees C Channel Power Measurement Input Frequency Range: 4 MHz to 1000 MHz Mesurement Range: -10 dBm to +48 dBm Measurement Accuracy: +/- 1 dB over a range of +/- 5 degrees C from the temperature of last calibration

Code Domain Analyzer

Code Domain Power Mesurement Input Frequency Range: 4 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Measurement Dynamic Range: 40 dB Measurement Accuracy: +/- 0.5 dB using a measurement interval >/= 0.5 ms Carrier Frequency Offset Accuracy: +/- 30 Hz using a measurement interval >/= 0.5 ms Pilot Time Offset Accuracy: typically <500 nsec from even second signal to start of PN sequence Code Domain Timing Measurement (Pilot to Code Channel Phase Tolerance) Input Level Range: 4 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Measurement Accuracy: +/- 10 ns using a measurement interval of 1.25msand >/= 10 averages Code Domain Phase Measurement (Pilot to Code Channel Phase Tolerance) Input Frequency Range: 1 MHz to 1000 MHz Input Level Range: RF In/Out: -10 dBm to +48 dBm Antenna: -46 dBm to +17 dBm Measurement Accuracy: +/- 20 mrad using a measurement interval of 1.25 ms and >/= averages

CDMA Reference

Input Frequencies: 19.6608 MHz, 15 MHz, 10 MHz, 9.8304 MHz, 5 MHz, 4.9152 MHz, 2.4576 MHz, 1.2288 MHz, and 1 MHz Even Second Sync Input: (BNC) accepts a rising edge to reset the internal short sequences and CDMA clocks. Periodic inputs should have a period of 2 seconds and a minimum pulse width of > 50 ns

CDPD Specifications

The following CDPD specifications apply when the HP 83205A option 002 or 003 is operating with the HP 8921A:

CDPD Signal Generator (at HP8921A DuplexOut)

Output:
Level Range and Level Accuracy: Same as HP 8921A Reverse Power: Same as HP 8921A Frequency Range: Same as HP 8921A Frequency Accuracy: ±500Hz, typically ±50Hz Spectral Purity: Spurious Signals, Adjacent Channels: <-26 dBc Spurious Signals, First Alternate Channel: <-45 dBc Spurious Signals, Second Alternate Channel: < 60 dBc Switching Speed: Typically <150 msec to be within 1 kHz Transmitter On/Off Level and Timing: >15 dB down in <1msec Modulation Type: GMSK with BT=0.5 Modulation Accuracy: <5% errorin modulation index

CDPD Analyzer

RF Frequency Range: Same as HP 8921A Input Level Range: Same as HP 8921A RF Power Measurement: Accuracy: RF in/out: 5%, ±0.01 mW (at 25°±10°C) for single signal >200 mw, 10% over full temperature range Frequency Error Accuracy: Time base accuracy ±1 Hz Modulation Index Accuracy: <0.1% error in modulation index Adjacent Channel Power measurement floor: Typically -45 dBc Alternate Channel Power measurement noise floor: Typically -55 dBc for input levels > -34 dBm


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 83205A	CDMA Cellular Adapter
   Opt 001	CDMA Cellular Adapter
   Opt 002      CDPD Cellular Adapter, upgradable to CDMA
   Opt 003      CDMA/CDPD Cellular Adapter
   Opt R13      CDPD Retrofit Kit for HP 83205A Opt. 001 to Opt. 003
   Opt R23      CDMA Retrofit kit for HP 83205A Opt. 002 to Opt. 003
   Opt W30      Three-Year Return Repair Service
   Opt W50      Five-Year Return Repair Service


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Monday October 05 20:03:27 UTC 1998