HP 83220E DCS/PCS MS Test Set |
The HP 83220E expands the capabilities of the HP 8922 family to
comprehensively test DCS 1800 and PCS 1900 equipment. The HP 83220E provides a cost
effective solution for mobile testing. All of the features of the HP
8922 are retained.
RF Generator Specifications
Frequency Range: 1805 to 1990 MHz Output RF In/Out Connector Level Range: -19 to -127 dBm Level Accuracy: +/- 1.0 dB, levels >/= -127 dBm +/- 1.0 dB, typically for levels >/= -127 dBm while hopping Reverse Power: 2 watts continuous 0.3 GMSK Modulation Frequency Error: +/- (0.01 ppm (22 Hz) + reference accuracy), for normal bursts
RF Analyzer Specifications
Frequency Range: 1710 to 1990 MHz CW RF Frequency Measurement Range: 1710 to 1990 MHz Level Range RF In/Out: -13 to +32 dBm CW RF Power Measurement Range: -5 to +32 dBm Accuracy: >/= 0 dBm, 1710 to 1880 MHz +/- 0.5 dB +/- noise -5 to 0 dBm, 1880 to 1990 MHz +/- 0.5 dB +/- noise(typical) Peak Transmitter Carrier Power Measurement Range: -5 to + 32 dBm Accuracy: >/= 0 dBm, 1710 to 1880 MHz +/- 0.6 dB +/- noise -5 to 0 dBm, 1880 to 1990 MHz +/- 0.6 dB +/- noise(typical) Amplitude Envelope Measurement Measurement Range RF In/Out: -13 to +32 dBm Phase and Frequency Measurement Measurement Range RF In/Out: -13 to +32 dBm Frequency Error Accuracy: +/-(0.01 ppm (22 Hz) + reference accuracy), for normal bursts
Spectrum Analyzer Specifications
Frequency Range: 1710 to 1990 MHz Reference Level Range RF In/Out: +35 to -45 dBm
HP 83220E DCS/PCS MS Test Set Opt 0B1 Provides a total of two sets of Users Guides (Users Guide only for A/E) Opt AX4 Rack Mount Flange Kit
Page Updated: Thursday June 19 16:17:48 UTC 1997