HP 83481A 20 GHz Electrical/3 GHz Optical Plug-In Module
| |||
![[ Summary ]](/tmo/datasheets/Graphics/tab-summary-high.gif)
![[ Features ]](/tmo/datasheets/Graphics/tab-features-reg.gif)
![[ Specifications ]](/tmo/datasheets/Graphics/tab-specs-reg.gif)
![[ Key Literature ]](/tmo/datasheets/Graphics/tab-keylit-reg.gif)
![[ Ordering ]](/tmo/datasheets/Graphics/tab-ordering-reg.gif)
![[ Assistance ]](/tmo/datasheets/Graphics/tab-assistance-reg.gif)
Optical channel:
Bandwidth (–3 dB): dc to 2.5 GHz (3 GHz typical)
Filtered bandwidth: Measured response conforms to ITU-TS G.957 and TA-NWT- 000253 for reference receivers for both
STM-1/OC-3 and STM-4/OC-12 data rates
Transition time: (10% to 90%, calculated from Tr = 0.48/BW optical)<=160 ps, unfiltered mode
Maximum RMS noise: <2.5 µW (<1.5 µW typical), 2.5 GHz or filtered mode
Connector type: 9/125 µm single mode, user selectable connector option
Electrical channel (identical to HP 83483A)
Bandwidth (-3dB): dc to 20 GHz or dc to 12.4 GHz (user-selectable)
Transition time: (10% to 90%, calculated from Tr = 0.35/bandwidth, typical): <=17.5 ps,
20 GHz mode, <=28.2 ps, 12.4 GHz mode
Maximum RMS noise: <=0.5 mV (0.25 mV typical), 12.4 GHz mode, <=1 mV (0.5 mV typical), 20 GHz mode
Connector type:3.5 mm(m)
General Specifications:
Mainframe Weight: 24.5 kg (54 lb)
Plug-In Module Weight: 1.1 kg (2.4 lb)
Mainframe Dimensions: (H x W x D) 238 x 433.6 x 624 mm
9.4 x 17.1 x 24.6 in
HP 83481A 20 GHz Electrical/3 GHz Optical Plug-In Module Opt 001 Latest operating system firmware for the HP 83480A Opt 002 Latest operating system firmware for the HP 54750A Select one connector type for the optical channel: Opt 012 FC/PC Opt 013 DIN Opt 014 ST Opt 015 Biconic Opt 017 SC Select configuration for the two internal, switchable filters: Opt 040 Fourth order 155 Mb/s and fourth order 622 Mb/s filters Opt 050 Fifth order 155 Mb/s and fifth order 622 Mb/s filters Opt 052 Fourth order 155 Mb/s and fifth order 155 Mb/s filters Opt 062 Fourth order 622 Mb/s and fifth order 622 Mb/s filters
HP 83480A Series Digital Communications Analyzer
(
PDF)
| If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
|
To help you make the right product choices
Related HP 54750A High-Bandwidth Digitizing Oscilloscope product datasheets:
Related product families available online:

Page Updated: Friday January 29 00:33:16 UTC 1999