HP 84110EM EMC Pre-production Evaluation System, 9 kHz to 1.8 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 84110EM has everything you need to perform radiated and conducted emissions measurements on your products and compare the results to agency limits. The system is based on the HP 8591EM EMC analyzer, which contains a quasi-peak adapter and dual I/O ports (HP-IB and parallel). The system also includes biconical and log periodic antennas, tripod, LISN, close field probe kit, limiter, and 10-meter cable.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Specifications

Frequency Range 50 ohms: 9 kHz to 1.8 GHz Frequency Reference Aging: ±2 x 106/year Temperature Stability: ±5 x 106 Initial Achievable Accuracy: ±0.5 x 106 Marker Count Accuracy Frequency Span <= 10 MHz x N* ±(marker frequency x frequence reference error1 + counter resolution + 100 Hz x N*) Frequency Span >=10 MHz x N*: ±(marker frequency x frequency reference error1 + counter resolution + 1 kHz x N*) Counter Resolution Frequency Span <=10 MHz x N*: Selectable from 10 Hz to 100 kHz Frequency Span >10 MHz x N*: Selectable from 100 Hz to 100 kHz Frequency Sweep Time Range Span = 0 Hz, > 1 kHz: 20 ms to 100 s Span = 0 Hz (Opt 101): 20 µ to 100 s Accuracy 20 ms to 100 s: ±=3% 20 µ to < 20 ms (Opt 101): ±=2% Sweep Trigger: Free run, single, line, video, external Resolution Bandwidth: 30 MHz to 3 MHz (3 dB) in 1-3-10 sequence 200 Hz, 9 kHz, and 120 kHz (6 dB) EMI bandwidths Accuracy: ±20% Selectivity (Characteristic) -60 dB/-3 dB 3 kHz to 10 kHz: 15:1 100 kHz to 3 MHz: 15:1 1 kHz, 30 kHz: 16:1 -40 dB/-3 dB 30 Hz to 300 Hz: 10:1 Video Bandwidth Range: 1 Hz to 1 MHz in 1, 3 sequence Stability Noise Sidebands (1 kHz RBW, 30 Hz VBW and sample detector) >10 kHz offset from CW signal <=-90 dBc/Hz + 20 Log N* >20 kHz offset from CW signal <=-100 dBc/Hz + 20 Log N* >30 kHz offset from CW signal <=-105 dBc/Hz + 20 Log N* Residual FM 1 kHz RBW, 1 kHz VBW <=250 Hz pk-pk in 100 ms 30 Hz RBW, 30 Hz VBW <=30 Hz pk-pk in 300 ms System-Related Sidebands >30 kHz offset from CW signal <=-65 dBc + 20Log N* *N = LO harmonic. N = 1. 1 Frequency reference error = (aging rate x period of time since adjustment + initial achievable accuracy + temperature stability).

Amplitude Specifications

Amplitude Range  
                              Displayed average noise level to +30 dBm

Maximum Safe Input Level (Input attenuator >=10 dB)
   Average continuous power:  +30 dBm (1 W)
   Peak pulse power:	      +30 dBm (1 W)
   dc:			      25 Vdc

Gain Compression
   >10 MHz:		          <= 0.5 dB (total power at input mixer2= -10 dBm)
Displayed Average Noise Level 
(Input terminated, 0 dB attenuation, 1 Hz VBW, sample detector)
				30 Hz RBW		1 kHz RBW
   400 kHz to 1 MHz		<= -130 dBm		<= -115 dBm
   1 MHz to 1.5 GHz		<= -130 dBm		<= -115 dBm
   1.5 GHz to 1.8 GHz		<= -128 dBm		<= -113 dBm

Spurious Responses
Second Harmonic Distortion
   5 MHz to 1.8 GHz:          <-70 dBc for -45 dBm tome at input mixer2
Third Order Intermodulation
Distortion
   5 MHz to 1.8 GHz:	      <-70 dBc for two -30 dBm tones at input mixer2 
			      and >50 kHz separation.

Other Input Related Spurious
   <=1.8 GHz:	              <-65 dBc at >=30 kHz offset, for 
			      -20 dBm tone at input mixer2

Residual Responses (Input terminated and dB attenuation)
   150 kHz to 1.8 GHz:	      <-90 dBm

Frequency Response (10 dB input attenuation)
			Absolute3		Relative Flatness4
   9 kHz to 1.8 GHz:	±1.5 dB				±1.0 dB

2Mixer Power Level 9 (dBm) - Input Attenuation(dB)
3Referenced to 300 MHz CAL OUT
4Referenced to midpoint between highest and lowest frequency response deviations.


General Specifications

Temperature Range Operating: 0 °C to +55 °C Storage:  -40 °C to +75 °C EMI Compatibility: Conducted and radiated interference CISPR Pub. 11 and Messempfaenger Postverfuegung 526/527/79 Audible Noise: <37.5 dBa pressure and <5.0 Bels power (ISODP7779) Power Requirements ON (Line 1): 86 to 127, or 195 to 250 V rms, 47 to 66 Hz, 103 to 126 V rms, 400 Hz +/- 10% Power consumption <300 VA; <100W Standby (Line 0): Power consumption <7W User Memory (nominal): 32 Kbytes non-volitile RAM Data Storage (nominal): 50 states and traces, internal memory and 8 internal state registers; 24 states and traces, memory card (HP 85700A)


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 84110EM	Preproduction Evaluation System, 9 kHz to 1.8 GHz
   Opt 001	Replaces 11967D LISN  with 11967D opt 001 LISN
   Opt 002	Replaces 11967D LISN with 11967D opt 002 LISN
   Opt 004	Adds precision frequency reference
   Opt 010	Adds the Tracking Generator
   Opt 015	Soft Tan Operating/Carrying Case
   Opt 016	Soft Yellow Operating/Carrying Case.
   Opt 043	Rpl HP-IB/parallel w/RS/parallel port
   Opt 093	Replaces HP 8591EM with HP 8593EM
   Opt 094	Replaces HP 8591EM with HP 8594EM
   Opt 095	Replaces HP 8591EM with HP 8595EM
   Opt 096	Replaces HP 8591EM with HP 8596EM
   Opt 193	Replaces HP 8591EM with HP 8593EM opt 010
   Opt 194	Replaces HP 8591EM with HP 8594EM opt 010
   Opt 195	Replaces HP 8591EM with HP 8595EM opt 010
   Opt 196	Replaces HP 8591EM with HP 8596EM opt 010
   Opt 61A      Adds the HP 11961A
   Opt UK6      Commercial cal. certificate w/ test data
   Opt W30      3 Year Return Repair Service
   Opt W32      3 Year Calibration Customer Return Svc.
   Opt W34      3 Year Standards Compliant Cal Service
   Opt W50      5 Year Return Repair Service
   Opt W52      5 Year Cust Return Calibration Service
   Opt W54      5 Year Standards Compliant Cal Service


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday February 05 06:16:32 UTC 1999