HP 8497K DC to 26.5 GHz Programmable Step Attenuator


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Summary

The HP 8497K dc to 26.5 GHz programmable step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 10 dB steps from 0 to 90 dB. Precision gold-plated leaf springs ensure long life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option 890. A maximum switching time of 20 ms (including contact settling) speeds automatic testing. Custom step attenuator/switch combinations are possible. The HP 11716A/B/C interconnect kits provide quick connection of HP 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Features



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Specifications

Electrical Specifications

Frequency Range: dc to 26.5 GHz Incremental Attenuation: 0 to 90 dB 10 dB steps SWR maximum (50 ohm nominal) dc to 6 GHz: 1.25 6 to 12.4 GHz: 1.45 12.4 to 18.0 GHz: 1.6 18.0 to 26.5 GHz: 1.8 Insertion Loss (0 dB setting): 0.6 dB + 0.09 dB/Ghz Attenuation Accuracy: ±3 dB at 6 GHz 10 dB attenuation to ±2.8 dB at 26.5 GHz 90 dB attenuation Power Rating, Minimum Life: 1W average, 100W peak, 10 µs max, 5 million cycles per section Solenoid Voltage: 5V or 24V

Option 890 Calibration Data Specifications

Frequency List (MHz): 100, 300, 500, 700, 900, 1000, 1250, 1500, 1750, 2000, 2500, 3000, 3500, 4000 and every 500 MHz 2 to 16 GHz, every 250 MHz to 16 to 26.5 GHz; every 500 MHz to 16000 (plus 12400 MHz), every 250 MHz from 16000 to 18000



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Ordering Information

Each order must include basic model number, suffix letter, and connector option.

HP 8497K	Programmable Step Attenuator
   Opt 890	Calibration Data

Connector options
   Opt 001	N(f)
   Opt 002	SMA (f)
   Opt 003	APC-7
   Opt 004	3.5 mm



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

To help you make the right instrument choices



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.