Vector Voltmeter Family |
The HP 8508A vector voltmeter is a two-channel receiver that makes high
frequency voltage measurements easy. Its narrowband measuring technique
gives it a sensitivity of 10 microV to help you measure even the
smallest signal. And that's only part of its capability. The HP 8508A
also measures the phase between two signals - so you can use it for
another complete set of measurements - like group delay and electrical
length. All standard HP 8508A vector voltmeters include an HP 85081B
high-impedance input module with a frequency range of 100 kHz to 1 GHz.
The HP 11570A accessory kit allows measurements in a 50 ohm system using
the probes of a standard HP 85081B. Option 050 replaces the HP 85081B
with an HP 85082A, a 50 ohm input module with a frequency range of 300
kHz to 2 GHz.
Related product datasheets available online:
Partial Specifications for HP 8508A
Frequency Range: With HP 85081B: 100 kHz to 1 GHz With HP 85082A: 300 kHz to 2 GHz Measurement Range (A and B Channel Maximum Input Levels) Magnitude Measurements HP 85081B HP 85082A 100 kHz to 1 MHz: 300 mV 300 kHz to 1 MHz: 3 dBm 1 MHz to 1 GHz: 1 V 13 dBm Phase Measurements 300 kHz to 1 GHz: 300 mV 300 kHz to 2 GHz: 3 dBm A (Ref) Channel Minimum Input Levels for Magnitude and Phase Measurements 100 kHz to 300 kHz 10 mV 300 kHz to 3 MHz: 1 mV -47 dBm 3 MHz to 1 GHz: 300 µV 3 MHz to 2 GHz: -57 dBm B (Meas) Channel Noise Floor 1 MHz to 1 GHz: 10 µV rms 1 MHz to 2 GHz: -87 dBm Input Crosstalk 100 kHz to 500 MHz: >100 dB 300 kHz to 500 MHz: >100 dB 500 MHz to 1 GHz: >80 dB >80 dB 1 GHz to 2 GHz: >70 dB Impedance SWR 100 kHz to 750 MHz: <1.15 300 kHz to 1.5 GHz: <1.2 750 MHz to 1 GHz: <1.45 1.5 GHz to 2 GHz: <1.5 Maximum Input (Damage Level): 2 Vac peak, ±50 Vdc 16 dBm, ±50 Vdc Measurement Bandwidth: 1 kHz (nominal) 1 kHz (nominal)General Characteristics
Lockup Time (Within 1 Range) Frequencies up to 3 MHz: 40 ms Frequencies >3 MHz: 20 ms Rear Panel Outputs Sensitivity: 1 mV per display digit Update Rate: Approximately 3 readings per second HP-IB Capability Interface Functions: SHI, AH1, T6, TE0, L4, LEO, SRI, RL1, PP0, DC1, DT1, CO Transfer Rate Normal Operation: Approximately 12 readings per second Maximum Rate: Approximately 1 reading per 18 ms Probe Power Supply Supplies: +12V, -12 V and ground to operate one HP 85024A High Impedance Probe Environment Temperature Operating: 0 to 55°C Storage: -40 to +70°C Humidity: 0 to 95%, non-condensing Altitude Operating: 0 to 4500 m (0 to 14800 ft) Storage: 0 to 15000 m (0 to 50000 ft) RFI: Conducted and radiated interference is within the requirements of Messempfaenger-Postverfuergung 526/527/79. Physical Size Standard: 133 mm H x 425.5 mm W x 473.3 mm D (5.25 in x 19.75 in x 20.65 in) Opt 001: 158.8 mm H x 524.5 mm W x 501.65 mm D (6.25 in x 19.75 in x 20.65 in) Weight Standard Net: 8.1 kg (18 lb) Shipping: 11 kg (24 lb) Opt 001 Net: 9.4 kg (21 lb) Shipping: 12.5 kg (27.5 lb) Power: 100, 120, 220, or 240 V +5/-10% 48 to 440 Hz, 40 VA
HP 8508A Vector Voltmeter (includes HP 85081B High Impedance Input Module) Opt 001 Adds Bail Handle, Rugged Feet, and Front Panel Storage Cover Opt 050 Replaces HP 85081B with HP 85082A 50 Ohm Input Module Opt 100 Deletes Input Module Opt 801 Additional Probe Accessories 2 each HP 10216A 2 each HP 11576A Opt 908 Rack Mount Kit (HP 5062-3977) for Instruments without Handles Opt 913 Rack Mount Kit (HP 5062-4071) for Instruments with Handles Opt W30 Additional Three-Year, Return-to-HP Hardware Support Opt W32 Three-Year Calibration Service HP 85081B High Impedance Input Module (100 kHz to 1 GHz) HP 85082A 50 Ohm Input Module (300 kHz to 2 GHz) HP 11570A 50 Ohm Accessory Kit HP 8508A User Documentation Opt 030 Japanese Operating Guide Opt 031 French Operating Guide Opt 032 German Operating Guide Opt 033 Italian Operating Guide Opt 034 Spanish Operating Guide