HP 85106C Millimeter-Wave Network Analyzer Subsystem (33 GHz to 110 GHz)


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Summary

When combined with the appropriate HP 85104A-series test set modules and HP 11644A-series calibration kits, the HP 85106C network analyzer subsystem provides a complete system for measurements in the millimeter-wave frequency range. The subsystem includes the HP 8510C network analyzer, an HP 85105A millimeter-wave controller, an HP 83621A synthesized source, and an HP 8350B/83540A source (LO), all mounted in a single-bay rack with extendable worksurface. Two HP 85104A series test set modules are required to complete the system. The instruments are integrated prior to shipment from the factory. Installation is included at no additional charge. With these configurations, both forward and reverse measurements can be made with a single connection to the device-under-test. The greatest convenience and highest accuracy is assured through the TRL (through-reflect-line) calibration technique. The HP 85106C can be configured as a combination microwave/millimeter-wave S-parameter system with Option 001.


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Features



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Specifications

Dynamic Range (for transmission measurements)

				Frequency Range (GHz)
				33-50	40-60	50-75	75-110
Maximum power (dBm)
	measured at port 2	+12 	+10 	+10 	0 
Reference power (dBm) 
	at port 1 (nominal)	0 	0 	0 	-3 
Minimum power (dBm) 
	measured at port 2	-87 	-87 	-75 	-79 
Receiver dynamic range (dB)	 99 	 97 	 85 	 79 
System dynamic range (dB)	 87 	 87 	 75 	 76



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Ordering Information

HP 85106C	Millimeter-Wave Network Analyzer Subsystem (33 GHz to 110 GHz)
   Opt 001	add microwave test set
 		(adds HP 8517B test set, HP 85056A calibration kit,
		HP 85133F cable set and Option 050 to HP 85105A mm-wave
		controller; replaces HP 83621A with HP 83651A synthesizer)
   Opt 002	synthesized LO source (replaces HP 8350B/83540A with HP 83621A synthesizer)
   Opt 007	add high power and high dynamic range configuration to the HP 8517B test set
   Opt 010	add time domain capability to HP 8510C
   Opt 230	20V/240V line voltage operation
   Opt W31	add two years additional on-site service

Note:  Two appropriate HP 85104A-series test set modules and an HP
11644A-series calibration kit must be ordered for a complete system.

All orders include the following:



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

To help you make the right instrument choices



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.