HP 8515A S-Parameter Test Set, 45 MHz to 26.5 GHz, 3.5 mm

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Several S-parameter tests sets are available for the HP 8510C network analyzer for broadband coaxial measurements from 45 MHz to 50 GHz. The HP 8515A test set has an architecture that develops a separate reference channel for each incident port. RF switching is done with a built-in electronic switch. For active device measurements, the test set includes the ability to apply dc bias (external) to the test port center conductors. Also available are two 90 dB step attenuators, which allow control of the port 1 and port 2 signal levels.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

General Specifications

Frequency Range: 0.045 to 26.5 GHz Test Ports (port 1 or 2) Nominal Operating Power Level: -5 to -25 dBm Connector Type: 3.5 mm, male Impedance, DC Bias: 50 ohm nominal, 500 mA, 40 Vdc maximum Attenuation Range (incident signal) 0 to 90 dB, in 10 dB steps RF Input Connector (rear panel) Max Input Power: +14 dBm Connector Type: 3.5 mm, female


Dynamic Range (for transmission measurements)

Frequency Range GHz .045 to 2 2 to 8 8 to 20 20 to 26.5 Maximum Power (dBm) Measured at Port 2: +2 +3 +3 -1 Reference Power (dBm) at Port 1 (nominal): -5 -9 -14 -25 Minimum Power (dBm) Measured at Port 2: -101 -102 -101 -99 Receiver Dynamic Range (dB): 103 105 104 100 System Dynamic Range (dB): 96 93 87 74


Measurement Port Characteristics Frequency Range (GHz) .045 to 2 2 to 8 8 to 20 20 to 26.5 Residual (dB) Directivity: 48 50 50 50 Source match: 40 50 50 50 Load match: 48 50 50 50 Reflection Tracking: ±0.003 ±0 ±0 ±0 Transmission Tracking: ±0.009 ±0.004 ±0.009 ±0.01 Crosstalk: 117 114 108 95 Raw (typical) (dB) (before calibration/error correction) Directivity: 24 24 28 27 Source Match: 23 23 16 14 Load Match: 23 23 16 14


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8515A     S-parameter Test Set, 45 MHz to 26.5 GHz, 3.5 mm
   Opt 001   Add IF switching circuitry
   Opt 002   Delete step attenuators and bias tees
   Opt 1BN   MIL-STD 45662A Calibration
   Opt 1BP   MIL-STD 45662A Calibration with Test Data
   Opt 908   Rack flange kit
   Opt 910   Additional operating and service manual
   Opt 913   Rack flange and handle kit
   Opt W03   Convert to standard 3 mo. on-site warr.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


Related HP 8510C Network Analyzer Coaxial Test Sets Family product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday February 18 07:48:00 UTC 1999