Several S-Parameter tests sets are available for the HP 8510C network analyzer for broadband coaxial measurements from 45 MHz to 50 GHz. The HP 8517B test set has an architecture that develops a separate reference channel for each incident port. RF switching is done with a built-in electronic switch. For active device measurements, the test sets include the ability to apply dc bias (external) to the test port center conductors. Also available are two 60 dB step attenuators, which allow control of the port 1 and port 2 signal levels. Option 007 high dynamic range configuration.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

General Specifications

Frequency Range 0.045 to 50 GHz Test Ports (port 1 or 2 Nominal Operating Power Level: +2 to -29 dBm Opt 007: +5 to -16 dBm Connector Type: 2.4 mm, male Impedance, DC Bias: 50 ohm nominal, 500 mA, 40 Vdc maximum Attenuation Range (incident signal): 0 to 60 dB, in 10 dB steps RF Input Connector (rear panel) Maximum Input Power: +16 dBm Connector Type: 2.4 mm, female


Dynamic Range (for transmission measurements)

Frequency Range GHz .045 0.84 20 40 to 0.84 to 20 to 40 to 50 Maximum Power (dBm) Measured at Port 2: +17 +8 +3 -4 Opt 007: +17 +12 +5 -5 Reference Power (dBm) at Port 1 (nominal): +2 -7 -17 -29 Opt 007: +5 +2 -5 -16 Minimum Power Measured at Port 2: -75 -97 -91 -90 Opt 007: -70 -92 -89 -91 Receiver Dynamic Range (dB): 92 105 94 86 Opt 007: 87 104 94 86 System Dynamic Range (dB: 77 90 74 61 Opt 007: 75 94 84 75


Measurement Port Characteristics Frequency Range GHz .045 0.84 20 40 to 0.84 to 20 to 40 to 50 Residual (dB) Directivity: 42 42 38 36 Source Match: 41 38 33 31 Load Match: 42 42 38 36 Reflection Tracking: ±0.001 ±0.008 ±0.02 ±0.027 Transmission Tracking: ±0.014 ±0.045 ±0.110 ±0.137 Crosstalk: 99 110 91 80 Raw (typical) (dB) (Before calibration/error correction) Directivity: 20 20 20 20 Source Match: 20 12 10 10 Load Match: 20 12 10 10


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8517B     S-Parameter Test Set,  0.045 to 50 GHz, 2.4 mm
   Opt 001   Add IF switching
   Opt 002   Delete step attenuators and bias tees
   Opt 004   High power test set configuration
   Opt 007   High dynamic range configuration


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


Related HP 8510C Network Analyzer Coaxial Test Sets Family product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday February 18 07:56:03 UTC 1999