HP 8542E EMI Receiver, 9 kHz to 2.9 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 8542E, 9 kHz to 2.9 GHz EMI test receiver makes CISPR-based EMI measurements with unprecedented accuracy, speed, and ease of use. It is fully CISPR 16-1 compliant, and can be used to check conformance to any civilian EMI standard, including CISPR, EN, FCC, VCCI, and VDE.

The HP 8542E works with our PC-based EMI measurement software (HP 85875A or 85876B) to create the most powerful, easiest-to-use automated solution available for commercial radiated and conducted emission testing. A built-in, PC-formatted floppy disk drive allows test and data files to be stored. The HP 8542E consists of two separate sections. The receiver RF section can be purchased as a standalone pre-compliance tester. The RF filter section can be added later to make the complete EMI compliance receiver.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Specifications

Tuning Range Band 1: 9 kHz to 50 MHz Band 2: 20 MHz to 2.9 GHz Band 3: 1 GHz to 6.5 GHz1 Bypass: 9 kHz to 2.9 GHz (to 6.5 GHz) HP 85422E/85462A: 9 kHz to 2.9 GHz (to 6.5 GHz) Frequency Readout Accuracy ±(frequency readout x frequency reference error2 + 1% of span + 20% of IF bandwidth + 100 Hz) Marker Count Accuracy Span <=10 MHz: ±(marker frequency x frequency reference error2 + counter resolution + span accuracy + 100 Hz) Span >10 MHz: ±(marker frequency x frequency reference error2 + counter resolution + 1 kHz) Frequency Reference Aging: <±1 x 10-7/year Settability: <±1 x 10-8 Temperature stability: <±1 x 10-8 Frequency Span Accuracy Span <=10 MHz: ±2% of span Span >10 MHz: ±3% of span HP 85422E Span <=10 MHz: ±2% of span + 10 Hz Counter Resolution Frequency Span <=10 MHz: selectable from 10 Hz to 100 kHz Frequency Span >10 MHz: selectable from 100 Hz to 100 kHz Sweep Time Range: 20 ms to 100 sec Sweep Trigger: free run, single, line, video, external 1For HP 8546A EMI receiver only 2Frequency reference error=(aging rate x period of time since last adjustment + initial achievable accuracy + temperature stability)

Amplitude Specifications

Characteristic Noise Indication with CISPR Measurement Bands (0 dB attenuation, 50 ohm input termination) Band A, 9 to 150 kHz (200 Hz BW) Peak Quasi-Peak Average Preamp Off: 15 to -15 dBµV 6 to -25 dBµV 3 to -27 dBµV Preamp On: 2 to -28 dBµV -7 to -29 dBµV -9 to -31 dBµV Band B, 150 kHz to 30 MHz (9 kHz BW) Preamp Off: -3 dBµV -11 dBµV -18 dBµV Preamp On: -8 dBµV -15 dBµV -21 dBµV Band C, 30 MHz to 1 GHz (120 kHz BW) Preamp Off: 9 dBµV 2 dBµV -5 dBµV Preamp On: 4 dBµV -2 dBµV -10 dBµV System Amplitude Accuracy 9 kHz to 2.9 GHz: +2 dB (typical ± 1 dB) Gain Compression, 1 dB (characteristic) 89 dB µV 77 dB µV

IF and Display Specifications

IF Bandwidths Measurement (6 dB): 200 Hz 9 kHz, 120 kHz (conforms to CISPP publication 16) Bandwidth Accuracy: 1 MHz, 6 dB BW ±10% Diagnostic (3 dB): 30 Hz to 3 MHz in a 1-3-10 sequence (±20% characteristic), also 3 MHz and 5 MHz Demodulation: AM and FM

General Specifications

Temperature Range: Operating: 0 °C to +55 °C Storage Media: 5 °C to 45 °C Storage: -20 °C to 65 °C Size: 458 mm W x 368 mm H x 644 mm D (18 in x 14 3/8 in x 25 3/8 in) Weight: 49 kg (108 lb)

Declarations of Conformity


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8542E        EMI Receiver, 9 kHz to 2.9 GHz
   Opt OB1	Add extra manual set
   Opt 1CM	Rack mount kit
   Opt 023	Substitutes RS-232 for HP-IB interface
   Opt W30      Three year return to HP service
   Opt UK6      Calibration data

HP 85422E	Receiver RF Section
HP 85420E	RF Filter Section

HP ITEL-45CHVU HP-IB-to-Centronics Adapter (Includes a 110-120V, 60 Hz AC adapter and NEMA (U.S.) style power cord) HP ITEL-45CHVE HP-IB-to-Centronics Adapter. No AC adapter included. (Order HP 82241A AC adapter with appropriate option.) Opt ABB Europe Opt ABG Australia Opt ABJ Japan Opt ABU United Kingdom HP C1405A 101-key, enhanced PC keyboard HP 85460-20036 Replacement semi-rigid cable for front panel HP 8120-8154 Replacement flexible cable for rear panel for high sweep or sweep ramp) HP 8120-6337 Replacement Auxiliary bus cable


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8542E 2.9 GHz Commercial EMI Receiver, Product Overview ( PDF)
HP 8542E & 8546A EMI Test Receivers, Technical Specifications ( PDF)
HP 85869PC EMI Measurement Software ( PDF)

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Additional help is a click away!

Want to talk to a knowledgeable engineer about this product at our HP Test and Measurement Call Center? Do you have a question you want to send in by e-mail? A measurement set-up you need to fax in? Follow the link above and you will be given a choice to contact an engineer by telephone, e-mail or fax.

This service is available only in the United States. For assistance outside the U.S., contact your local HP DIRECT or HP Sales Office.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related Information:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday February 18 07:56:08 UTC 1999