HP 85640A Portable Tracking Generator, 300 kHz to 2.9 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 85640A is a MIL-Rugged portable tracking generator to be used with the HP 8560A, 8561A/B, or 8562A/B portable spectrum analyzer.

Combining the HP 85640A tracking generator with a portable spectrum analyzer results in a system having both scalar-analysis and spectrum-analysis capabilities. Use the scalar-analysis capability to perform measurements such as gain, frequency reponse, compression, flatness, and return loss on components and subsystems. Use the spectrum analysis capability to measure harmonic and inter-modulation distortion, as well as spurious products.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency and Amplitude Specifications

Frequency Range: 300 kHz to 2.9 GHz Tracking Drift (after 30 min warmup) 300 Hz per hour, nominal Output Power Level Maximum: 0 dBm Range: -80 dBm to 0 dBm Resolution: 10 dB with attenuation vernier continously adjustable Flatness: ±2.0 dB, reference to 300 MHz with 10 dB attenuation Vernier Range: >10 dB Output Attenuator Range: 70 dB Switching Accuracy (10-70 dB settings ref to 0 dB) ±0.8 dB/10 dB ±1.5 dB, maximum Repeatability: ±0.2 dB, nominal Spurious Output (-10 dBm, 10 dB atten) Harmonic Spurs: <-25 dBc Non-Harmonic Spurs 300 kHz to 2.0 GHz: <-27 dBc 2.0 to 2.9 GHz: <-23 dBc LO Feedthrough (>2.9 GHz): <-26 dBm Output Return Loss 0 dB Attenuation: 10 dB 10 dB Attenuation: 17 dB, nominal Dynamic Range (1 MHz to 2.9 GHz, 300 Hz RBW) 300 kHz to 1 MHz: 95 dB 1 MHz to 2.7 GHz: 115 dB 2.7 to 2.9 GHz: 110 dB Minimum RBW Supported: 300 Hz; 100 Hz (HP 8561A, 8562A/B)

Inputs and Outputs

RF Output: Type-N (f), front panel Impedance: 50 ohms, nominal 300 MHz Input: BNC (f), front panel LO Input: SMA (f), front panel 0.5 V per GHz Input: BNC (f), rear panel Blanking Input: BNC (f), rear panel Ext ALC Input: BNC (f), rear panel, use with negative detector

General Specifications

Warmup: 5 minutes from ambient Temperature Operating: -10 °C to +50 °C Storage: -62 °C to +85 °C Humidity: 95% at 40 °C for 5 days Altitude Operating: 15,000 ft Storage: 50,000 ft Vibration 5 to 15 Hz: 0.059 inch p-p excursion 15 to 25 Hz: 0.039 inch p-p excursion 25 to 55 Hz: 0.020 inch p-p excursion Pulse Shock (Half Sine): 30 g's for 11 ms duration Transit Drop: 8-inch drop on 6 faces and 8 corners Electromagnetic Capability: Conducted and radiated interference is in compliance with CISPR publication 11 (1985) and FTZ 526/527/79. Meets MIL-STD-461B, Part 4, with exceptions Power Requirements: 110, 120, 220 or 240 V (±10%) 47 to 66 Hz Maximum Power Dissipation: 130 VA, 35 W Weight: 8.4 kg (18.5 lbs), nominal Compatibility: Works with HP 8560A, 8561A/B, and 8562A/B portable spectrum analyzers.

Declarations of Conformity


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 85640A     Portable Tracking Generator, 300 kHz to 2.9 GHz
   Opt 908    Rackmount kit
   Opt 909    Rackmount kit with handles
   Opt 910    Extra operation/service manuals
   Opt W30    2 additional years return to HP service
   Opt W32    3 years return to HP calibration


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 85640A Portable Tracking Generator, Technical Data ( PDF)

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


Related HP 8560 E-Series High-Performance Spectrum Analyzers product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday February 18 10:01:55 UTC 1999