HP 8594Q QAM Analyzer, 9 kHz to 2.9 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
All cable TV network operators planning the introduction of digital services have increasing competitive pressure to install these new services - quickly. Aggressive activation schedules require test equipment capable of verifying your quality of service - fast.

The HP 8594Q QAM (Quadrature Amplitude Modulation) analyzer is a comprehensive and powerful test solution, primarily designed for installation and maintenance test on European DVB-C systems. Supporting 8, 4 and 2 MHz channel bandwidths, the HP 8594Q QAM analyzer makes both qualitative and quantitative measurements on the transmitted 64 QAM signal. It gives engineers the measurement capability required to accurately verify the quality of service delivered to subscribers. All measurements are presented in a user-friendly manner so the engineer can focus on the job at hand, not on operating the test equipment.

Option J91 supports the 6 MHz channel bandwidth and symbol rates used on cable systems in North America and elsewhere.

The HP 8594Q QAM analyzer can help you during: headend equipment installation and maintenance, system verification, field installation and maintenance, and modulator manufacturing test.

The HP 8594Q QAM analyzer demodulates and accurately measures the QAM signals carried through the DVB-C system. It provides new measurement metrics necessary to characterize these signals and troubleshoot problems. The HP 8594Q QAM analyzer's graphical displays, clear user interface, and one-button measurement capability will make the transition from analog to digital testing easy for cable TV engineers.

Add option 195 to the HP 8594Q QAM analyzer to verify that the DVB-C MPEG data has been correctly decoded, and check transport stream content. The option also provides a real-time output (both ASI and parallel), to allow access to the data stream for further comprehensive MPEG analysis with products such as the HP E6277B MPEGscope Plus Test System.

Click here for a demo of the HP 8594Q QAM Analyzer.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

1DVB-C is a standard defined by the European Telecommunications Standards Institute


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Range:              9 kHz to 2.9 GHz

DVB-C Channel Bandwidths:     8 MHz, 4 MHz and 2 MHz (6 MHZ, option J91)

Supported Symbol Rates (Characteristics)

Channel       8 MHz	          4 MHz 	       2 MHz                6 MHz (opt J91)
Bandwidth
----------------------------------------------------------------------------------------------
Symbol Rate   6.9 MSymbol/s       3.45 MSymbol/s       1.725 MSymbol/s      5.056941 MSymbol/s 
	      6.89 MSymbol/s      3.445 MSymbol/s      1.72 MSymbol/s       5.360537 MSymbol/s   
	      6.875 MSymbol/s     3.4375 MSymbol/s     1.71875 MSymbol/s    5.274 MSymbol/s 
	      6.872 MSymbol/s     3.436 MSymbol/s      1.718 MSymbol/s 


General Specification

Temperature Range Operating: 0 °C to +55 °C Storage: -40 °C to +75 °C EMI Compatibility: Conducted and radiated interference CISPR Pub. 11 and Messempfaenger Postverfuegung 526/527/79 Audible Noise: <37.5 dBa pressure and <5.0 Bels power (ISODP7779) Power Requirements ON Line 1: 90 to 132 V rms, 47 to 440 Hz,195 to 250 V rms, 47 to 66 Hz Power consumption <500 VA; <180W Standby Line 0: Power consumption <7 W Data Storage (nominal): Internal 24 traces or 32 states Dimensions Without Handle, Feet, or Cover 163 mm (H) x 325 mm (W) x 427 mm (D) Overall: 184 mm (H) x 373 mm (W) X 461 mm (D) Weight Net: 16.4 kg (36 lb) Shipping: 19.1 kg (42 lb)

Declarations of Conformity


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8594Q      QAM Analyzer, 9 kHz to 2.9 GHz
   Opt 1902   DVB-C RF and modulation quality measurements
   Opt J913   6 MHz Channel Operation
   Opt 016    Soft Yellow Operating/Carrying Case
   Opt 040    Front Panel Protective Cover with Storage
   Opt 042    Protective Soft Carrying Case
   Opt 043    RS232/Parallel Interface
   Opt 1954   Data Measurements
   Opt 704    Delete Precision Reference
   Opt 908    Rackmount Kit without Handles
   Opt 909    Rackmount Kit with Handles
   Opt 910    Additional Manual Set

2 Required option for standard operation
3 Required option for 6 MHz operation, not compatible with opt 190
4 Option 195 measurements are specific to the European DVB
standard.  This is not compatible with other video standards.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

DVB-C Solutions - HP 8594Q QAM Analyzer, Product Overview
DVB-C Solutions, Product Note

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related Information:


Related HP 8590 E-Series Portable Spectrum Analyzer Family product datasheets:


Related HP Cable TV Test Equipment product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Monday October 05 19:25:54 UTC 1998