HP 8596E Portable Spectrum Analyzer, 9 kHz to 12.8 GHz

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 8596E is an easy-to-use microwave spectrum analyzer that offers a wide range of performance, features, and optional capability to meet your measurement needs. Downloadable measurement personalities combine with optional plug-in performance to provide tailored solutions for your application.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Frequency Specifications

Frequency Range Band LO Harmonic = N Range 0 1 9 kHz to 2.9 GHz (dc-coupled) 0 1 100 kHz to 2.9 GHz (ac-coupled) 1 1 2.75 to 6.5 GHz 2 2 6.0 to 12.8 GHz Frequency Reference Aging: ±2 x 10-6/year; ±l x 10-7/year (Opt 004) Temperature Stabililty: ±5 x 10-6, ±l x 10-8 (Opt 004) Initial Achievable Accuracy: ±0.5 x 10-6; ±2.2 x 10-8 (Opt 004) Frequency Readout Accuracy (start, stop, center, marker): ±(frequency readout x freq ref error + span accuracy + 1% of span + 20% of RBW + 100 Hz x N) Marker Frequency Counter Accuracy Span <=10 MHz x N: ±(marker freq x freq ref error + counter res + 100 Hz x N) Span >10 MHz x N: ±(marker freq x freq ref error + counter res + 1 kHz x N) Counter Resolution Span <=10 MHz x N: Selectable from 10 Hz to 100 kHz Span >10 MHz x N: Selectable from 100 Hz to 100 kHz Frequency Span Range: 0 Hz (zero span) and [10 x N] kHz to 12.8 GHz; [1 x N] kHz minimum (Opt 130) Resolution: Four digits or 20 Hz x N, whichever is greater Accuracy Span <=10 MHz x N: ±2% of span Span >10 MHz x N: ±3% of span Sweep Time Range Span = 0 Hz or >1 kHz: 20 ms to 100 s Span = 0 Hz (Opt 101): 20 µs to 100 s Accuracy 20 ms to 100 s: ±3% 20 µs to <20 ms (Opt 101): ±2% Sweep Trigger: Free run, single, line, video, external Bandwidth Filters Resolution Bandwidths: 1 kHz to 3 MHz (3 dB) in 1, 3, 10 sequence; 9 kHz and 120 kHz (6 dB) EMI bandwidths. Option 130 adds 30, 100, and 300 Hz (3 dB) bandwidths and 200 Hz (6 dB) EMI bandwidth. Accuracy: ±20% Selectivity (characteristic) -60 dB/-3 dB: 3 to 10 kHz 15:1 100 kHz to 3 MHz 15:1 1 kHz, 30 kHz 16:1 -40 dB/-3 dB: 30 Hz to 300 Hz 10:1 Video Bandwidth Range: 30 Hz to 1 MHz in 1, 3 sequence (1 Hz to 1 MHz with Opt 130) Stability Noise Sidebands (1 kHz RBW, 30 Hz VBW, sample detector) >10 kHz offset from CW signal: <=-90 dBc/Hz + 20 log N >20 kHz offset from CW signal: <=-100 dBc/Hz + 20 log N >30 kHz oftset from CW signal: <=-105 dBc/Hz + 20 log N Residual FM 1 kHz RBW, 1 kHz VBW: <=(250 x N) Hz p-p in 100 ms 30 Hz RBW, 30 Hz VBW: <=(30 x N) Hz p-p in 300 ms System Related Sidebands (>30 kHz offset from CW signal): <=-65 dBc + 20 log N Comb Generator Fundamental: 100 MHz Frequency Accuracy: ±0.007%

Amplitude Specifications

Amplitude Range Measurement Range: Displayed average noise level to +30 dBm Maximum Safe Input (input attenuator >=10 dB) Average Continuous Power: +30 dBm (1 W) Peak Pulse Power: +50 dBm (100 W) for < 10 µs pulse width and <1% duty cycle, input atten >=30 dB DC: 0 V (dc-coupled); 50 V (ac-coupled) Gain Compression (>10 MHz): <=0.5 dB (total power at input mixer = -10 dBm) Displayed Average Noise Level (input terminated, 0 dB atten, 30 Hz VBW or 1 Hz VBW with Opt 130, sample detector) 30 Hz RBW 1 kHz RBW 400 kHz to 2.9 GHz <=-125 dBm <=-110 dBm 2.75 GHz to 6.5 GHz <=-127 dBm <=-112 dBm 6.0 GHz to 12.8 GHz <=-115 dBm <=-100 dBm Display Range Log Scale: 0 to -70 dB from ref level is calibrated; 0.1, 0.2, 0.5 dB/div and 1 to 20 dB/div in 1 dB steps; 8 div displayed Linear Scale: 8 divisions Scale Units: dBm, dBmV, dBµV, V, W Marker Readout Resolution Log Scale: 0.05 dB Linear Scale: 0.05% of ref level Fast Time Sweep For Zero Span (Opt 101 or 301, 20 µs to 20 ms) <=1 GHz: 0.7% of ref level for linear scale >1 GHz: 1.0% of ref level for linear scale Reference Level Range: Same as amplitude range Resolution: ±0.01 dB for log scale; ±0.12% of ref level for linear scale Accuracy: ±0.3 dB at -20 dBm 0 to -59.9 dBm: ±(0.3 dB + 0.01 x dB from -20 dBm) Spurious Responses Second Harmonic Distortion >10 MHz: <-70 dBc for -40 dBm tone at input mixer >2.75 GHz: <-100 dBc for -10 dBm tone at mixer (or below DANL) Third-Order Intermodulation >10 MHz: <-70 dBc for two -30 dBm tones at input and >50 kHz separation Other Input-Related Spurious (>=30 kHz offset, -20 dBm tone at input mixer) <-65 dBc Residual Responses (input terminated, 0 dB attenuation) 150 kHz to 6.5 GHz: <-90 dBm Frequency Response (10 dB input attenuation) Absolute (referenced to 300 MHz CAL OUT): ±1.5 dB to ±2.5 dB (preselector peaked) Relative Flatness (referenced to midpoint between highest and lowest frequency response deviations): ±1.0 dB to ±2.0 dB Calibrator Output Amplitude: -20 dBm ±0.4 dB Resolution Bandwidth Switching Uncertainty (ref to 3 kHz RBW, at ref level) 3 kHz to 3 MHz RBW: ±0.4 dB 1 kHz RBW: ±0.5 dB 30 Hz to 300 Hz RBW: ±0.6 dB Log to Linear Switching: ±0.25 dB at ref level Display Scale Fidelity Log Incremental Accuracy (0 to -60 dB from ref level): ±0.4 dB/4 dB Log Maximum Cumulative (0 to -70 dB from ref level) 3 kHz to 3 MHz RBW ±(0.3 + 0.01 x dB from ref level) 30 Hz to 3 kHz RBW ±(0.4 + 0.01 x dB from ref level) Linear Accuracy: ±3% of ref level

General Specifications

Environmental MIL-T-28800: Has been type-tested to the environmental specifications of MIL-T-28800 Class 5 Temperature Operating: 0 °C to +55 °C Storage: -40 °C to +75 °C EMI Compatibility: Conducted and radiated interference CISPR Pub.11 and Messempfaenger Postverfuegung 526/527/79 Audible Noise: <37.5 dBA pressure and <5.0 Bels power (ISODP7779) Power Requirements On (line 1): 90 to 132 V rms, 47 to 440 Hz 195 to 250 V rms, 47 to 66 Hz Power consumption <500 VA; <180 W Standby (line 0): Power consumption <7 W Memory User Program Memory (nominal): 238 KB nonvolatile RAM Data Storage (nominal) Internal: 50 traces, 8 states External Memory Cards: HP 85700A (32 KB), 24 traces or 32 states HP 85702A (128 KB), 99 traces or 128 states Video Cassette Recorder: Continuous video recording of display supported through composite video output Size (nominal, without handle, feet, or cover): 325 mm W x 163 mm H x 427mm D Weight: 16.4 kg

Option 010 and 011 Built-In Tracking Generators

Frequency Range Opt 010: 9 kHz to 2.9 GHz Output Level Range Opt 010: -1 to 66 dBm Resolution: 0.1 dB Absolute Accuracy: ±0.5 dB Vernier Range: 9 dB Accuracy: ±0.8 dB Output Flatness: ±2 dB, >10 MHz Spurious Output Harmonic Spurs: -1 dBm output; <-25 dBc Nonharmonic Spurs: <-30 dBc Dynamic Range (characteristic, max output level - TG feedthrough) Opt 010: 111 dB, >400 kHz Power Sweep Range Opt 010: -66 dBm to -1 dBm in 8 dB increments Resolution: 0.1 dB

Declarations of Conformity


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8596E       Portable Spectrum Analyzer, 9 kHz to 12.8 GHz

General Options
   Opt 004     Precision Frequency Reference
   Opt 009     Lo and Sweep + Tune
   Opt 015     Soft Tan Carrying/Operating Case
   Opt 016     Soft Yellow Carrying/Operating Case

   Opt 040     Front Panel Protective Cover With Storage
   Opt 041     HP-IB and Parallel Printer Interfaces
   Opt 042     Protective Soft Carrying Case/Backpack
   Opt 043     RS-232 and Parallel Printer Interfaces

   Opt 101     Fast Time Domain Sweeps and Analog + Display
   Opt 102     AM/FM Demodulator and TV Sync Trigger (TV Sync requires Opt 101)
   Opt 130     Narrow Resolution Bandwidths (30 to 300 Hz and 200 Hz EMI)
   Opt 140     Narrow Bandwidths and Precision Frequency Reference
   Opt 301     TV Sync Trigger, Fast Time Domain Sweeps, AM/FM Demodulator,
               Analog + Display

   Opt 908     Rackmount Kit without Handles
   Opt 909     Rackmount Kit with Handles

Communications Bundling
Opt BD0 CDMA Bundle
   Opt 004     Precision Frequency Reference
   Opt 053     Improved Amplitude Accuracy for CDMA
   Opt 105     Time-Gated Spectrum Analysis
   Opt 151     DSP, Fast ADC and Digital Demodulator
   Opt 160     PDC/PHS/NADC/CDMA FW for Opt 151 HW
   85725C      CDMA Test Personality for 8590 E-Series

Opt BD1 GSM Bundle
   Opt 004     Precision Frequency Reference
   Opt 105     Time-Gated Spectrum Analysis
   Opt 151     DSP, Fast ADC and Digital Demodulator
   Opt 163     GSM/DCS Firmware for Phase/Frequency Error
   85727A      GSM Multi-Band Transmitter Measurement Personality

Opt BD2 TDMA/NADC Bundle
   Opt 004     Precision Frequency Reference
   Opt 050     Improved Amplitude Accuracy for NADC/PCS
   Opt 105     Time-Gated Spectrum Analysis
   Opt 151     DSP, Fast ADC and Digital Demodulator
   Opt 160     PDC/PHS/NADC/CDMA FW for Opt 151 HW
   85718B      NADC/PCS-TDMA Measurement Personality

Opt BD3 PDC Bundle
   Opt 004     Precision Frequency Reference
   Opt 051     Improved Amplitude Accuracy for PDC
   Opt 105     Time-Gated Spectrum Analysis
   Opt 151     DSP, Fast ADC and Digital Demodulator
   Opt 160     PDC/PHS/NADC/CDMA FW for Opt 151 HW
   85720C      BDC Test Personality for 8590 E-Series

Opt BD4 PHS Bundle
   Opt 004     Precision Frequency Reference
   Opt 052     Improved Amplitude Accuracy for PHS Band
   Opt 105     Time-Gated Spectrum Analysis
   Opt 151     DSP, Fast ADC and Digital Demodulator
   Opt 160     PDC/PHS/NADC/CDMA FW for Opt 151 HW
   85726B      PHS Measurement Personality for 8590 E-Series

Component Test Options
   Opt 010     Tracking Generator (9 kHz to 2.9 GHz)
   Opt 119     Noise Figure

Cable TV Options
   Opt 011     Tracking Generator (75 ohm)
   Opt 107     TV Receiver Video Tester
   Opt 180     TV Picture NTSC/PAL/SECAM
   Opt 711     50/75 ohm Matching Pad/100 Vdc Block

Communications Options
   Opt 012     Source for DECT Receiver Test
   Opt 050     Improved Amplitude Accuracy (NADC - TDMA bands)
   Opt 051     Improved Amplitude Accuracy for PDC Bands
   Opt 052     Inproved Amplitude Accurancy for PHS Band
   Opt 053     Improved Amplitude Accuracy for CDMA Bands

   Opt 105     Time-Gated Spectrum Analysis
   Opt 110     CT2 Demodulator
   Opt 111     Group Delay and Amplitude Flatness
               (also requires the HP 11770A Link Measurement Personality)
   Opt 112     DECT Demodulator
   Opt 151     DSP, FAST ADC, and Digital Demodulator
   Opt 160     PDC, PHS, NACD, and CDMA Firmware for Option 151
   Opt 163     GSM/DCS1800 Firmware for Option 151

EMC Options
   Opt 103     Quasi-Peak Detector, AM/FM Demodulator

Warranty and Support Options
   Opt 0Q8     Factory Service Training
   Opt UK6     Commercial Calibration Certificate with Test Data
   Opt AB*     Quick Reference Guide in Local Languages
   Opt W30     Two Additional Years Return-to-HP Service
   Opt W32     Two Additional Years Return-to-HP Calibration
   Opt 915     Component Level Information and Service Guide

Most options can be retrofitted. Please contact your local
HP sales representative.

Application Measurement Cards/Personalities

HP 85700A      Blank 32-KB Memory Card
HP 85702A      Blank 128-KB Memory Card
HP 11770A      Link Measurement Personality
HP 85712D      EMC Measurement Personality
HP 85713A      Digital Radio Measurement Personality
HP 85714A      Scalar Measurement Personality
HP 85715B      GSM Measurement Personality
HP 85717A      CT2-CAI Measurement Personality
HP 85718B      NADC-TDMA Measurement Personality
HP 85719A      Noise Figure Measurement Personality
HP 85720C      PDC Measurement Personality
HP 85721A      Cable TV Measurement Personality
HP 85722B      DCS1800 /PCS1900 Measurement Personality
HP 85723A      DECT Measurement Personality
HP 85724A      Broadcast Measurement Personality
HP 85725C      CDMA Measurement Personality
HP 85726B      PHS Measurement Personality
HP 85727A      GSM Multi-band Measurement Personality
HP 85921A      Cable TV PC Software for HP 85721A

Some measurement personalities are not supported by all HP 8590
series models.

For complete information, please contact your local HP sales
representative.

Available accessories for this product include:


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8590 E-Series Portable Spectrum Analyzers, Technical Specifications
HP 8590L Series Portable Spectrum Analyzers, Product Overview
HP 8590 E-Series Spectrum Analyzers and the Options and Attachments that are Compatible with them, Configuration Guide

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related Information:


Related HP 8590 E-Series Portable Spectrum Analyzer Family product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Thursday November 12 21:44:42 UTC 1998