HP 8596E Portable Spectrum Analyzer, 9 kHz to 12.8 GHz
| |||
![[ Summary ]](/tmo/datasheets/Graphics/tab-summary-high.gif)
![[ Features ]](/tmo/datasheets/Graphics/tab-features-reg.gif)
![[ Specifications ]](/tmo/datasheets/Graphics/tab-specs-reg.gif)
![[ Key Literature ]](/tmo/datasheets/Graphics/tab-keylit-reg.gif)
![[ Ordering ]](/tmo/datasheets/Graphics/tab-ordering-reg.gif)
![[ Assistance ]](/tmo/datasheets/Graphics/tab-assistance-reg.gif)
Frequency Specifications
Frequency Range Band LO Harmonic = N Range 0 1 9 kHz to 2.9 GHz (dc-coupled) 0 1 100 kHz to 2.9 GHz (ac-coupled) 1 1 2.75 to 6.5 GHz 2 2 6.0 to 12.8 GHz Frequency Reference Aging: ±2 x 10-6/year; ±l x 10-7/year (Opt 004) Temperature Stabililty: ±5 x 10-6, ±l x 10-8 (Opt 004) Initial Achievable Accuracy: ±0.5 x 10-6; ±2.2 x 10-8 (Opt 004) Frequency Readout Accuracy (start, stop, center, marker): ±(frequency readout x freq ref error + span accuracy + 1% of span + 20% of RBW + 100 Hz x N) Marker Frequency Counter Accuracy Span <=10 MHz x N: ±(marker freq x freq ref error + counter res + 100 Hz x N) Span >10 MHz x N: ±(marker freq x freq ref error + counter res + 1 kHz x N) Counter Resolution Span <=10 MHz x N: Selectable from 10 Hz to 100 kHz Span >10 MHz x N: Selectable from 100 Hz to 100 kHz Frequency Span Range: 0 Hz (zero span) and [10 x N] kHz to 12.8 GHz; [1 x N] kHz minimum (Opt 130) Resolution: Four digits or 20 Hz x N, whichever is greater Accuracy Span <=10 MHz x N: ±2% of span Span >10 MHz x N: ±3% of span Sweep Time Range Span = 0 Hz or >1 kHz: 20 ms to 100 s Span = 0 Hz (Opt 101): 20 µs to 100 s Accuracy 20 ms to 100 s: ±3% 20 µs to <20 ms (Opt 101): ±2% Sweep Trigger: Free run, single, line, video, external Bandwidth Filters Resolution Bandwidths: 1 kHz to 3 MHz (3 dB) in 1, 3, 10 sequence; 9 kHz and 120 kHz (6 dB) EMI bandwidths. Option 130 adds 30, 100, and 300 Hz (3 dB) bandwidths and 200 Hz (6 dB) EMI bandwidth. Accuracy: ±20% Selectivity (characteristic) -60 dB/-3 dB: 3 to 10 kHz 15:1 100 kHz to 3 MHz 15:1 1 kHz, 30 kHz 16:1 -40 dB/-3 dB: 30 Hz to 300 Hz 10:1 Video Bandwidth Range: 30 Hz to 1 MHz in 1, 3 sequence (1 Hz to 1 MHz with Opt 130) Stability Noise Sidebands (1 kHz RBW, 30 Hz VBW, sample detector) >10 kHz offset from CW signal: <=-90 dBc/Hz + 20 log N >20 kHz offset from CW signal: <=-100 dBc/Hz + 20 log N >30 kHz oftset from CW signal: <=-105 dBc/Hz + 20 log N Residual FM 1 kHz RBW, 1 kHz VBW: <=(250 x N) Hz p-p in 100 ms 30 Hz RBW, 30 Hz VBW: <=(30 x N) Hz p-p in 300 ms System Related Sidebands (>30 kHz offset from CW signal): <=-65 dBc + 20 log N Comb Generator Fundamental: 100 MHz Frequency Accuracy: ±0.007%
Amplitude Specifications
Amplitude Range Measurement Range: Displayed average noise level to +30 dBm Maximum Safe Input (input attenuator >=10 dB) Average Continuous Power: +30 dBm (1 W) Peak Pulse Power: +50 dBm (100 W) for < 10 µs pulse width and <1% duty cycle, input atten >=30 dB DC: 0 V (dc-coupled); 50 V (ac-coupled) Gain Compression (>10 MHz): <=0.5 dB (total power at input mixer = -10 dBm) Displayed Average Noise Level (input terminated, 0 dB atten, 30 Hz VBW or 1 Hz VBW with Opt 130, sample detector) 30 Hz RBW 1 kHz RBW 400 kHz to 2.9 GHz <=-125 dBm <=-110 dBm 2.75 GHz to 6.5 GHz <=-127 dBm <=-112 dBm 6.0 GHz to 12.8 GHz <=-115 dBm <=-100 dBm Display Range Log Scale: 0 to -70 dB from ref level is calibrated; 0.1, 0.2, 0.5 dB/div and 1 to 20 dB/div in 1 dB steps; 8 div displayed Linear Scale: 8 divisions Scale Units: dBm, dBmV, dBµV, V, W Marker Readout Resolution Log Scale: 0.05 dB Linear Scale: 0.05% of ref level Fast Time Sweep For Zero Span (Opt 101 or 301, 20 µs to 20 ms) <=1 GHz: 0.7% of ref level for linear scale >1 GHz: 1.0% of ref level for linear scale Reference Level Range: Same as amplitude range Resolution: ±0.01 dB for log scale; ±0.12% of ref level for linear scale Accuracy: ±0.3 dB at -20 dBm 0 to -59.9 dBm: ±(0.3 dB + 0.01 x dB from -20 dBm) Spurious Responses Second Harmonic Distortion >10 MHz: <-70 dBc for -40 dBm tone at input mixer >2.75 GHz: <-100 dBc for -10 dBm tone at mixer (or below DANL) Third-Order Intermodulation >10 MHz: <-70 dBc for two -30 dBm tones at input and >50 kHz separation Other Input-Related Spurious (>=30 kHz offset, -20 dBm tone at input mixer) <-65 dBc Residual Responses (input terminated, 0 dB attenuation) 150 kHz to 6.5 GHz: <-90 dBm Frequency Response (10 dB input attenuation) Absolute (referenced to 300 MHz CAL OUT): ±1.5 dB to ±2.5 dB (preselector peaked) Relative Flatness (referenced to midpoint between highest and lowest frequency response deviations): ±1.0 dB to ±2.0 dB Calibrator Output Amplitude: -20 dBm ±0.4 dB Resolution Bandwidth Switching Uncertainty (ref to 3 kHz RBW, at ref level) 3 kHz to 3 MHz RBW: ±0.4 dB 1 kHz RBW: ±0.5 dB 30 Hz to 300 Hz RBW: ±0.6 dB Log to Linear Switching: ±0.25 dB at ref level Display Scale Fidelity Log Incremental Accuracy (0 to -60 dB from ref level): ±0.4 dB/4 dB Log Maximum Cumulative (0 to -70 dB from ref level) 3 kHz to 3 MHz RBW ±(0.3 + 0.01 x dB from ref level) 30 Hz to 3 kHz RBW ±(0.4 + 0.01 x dB from ref level) Linear Accuracy: ±3% of ref level
General Specifications
Environmental MIL-T-28800: Has been type-tested to the environmental specifications of MIL-T-28800 Class 5 Temperature Operating: 0 °C to +55 °C Storage: -40 °C to +75 °C EMI Compatibility: Conducted and radiated interference CISPR Pub.11 and Messempfaenger Postverfuegung 526/527/79 Audible Noise: <37.5 dBA pressure and <5.0 Bels power (ISODP7779) Power Requirements On (line 1): 90 to 132 V rms, 47 to 440 Hz 195 to 250 V rms, 47 to 66 Hz Power consumption <500 VA; <180 W Standby (line 0): Power consumption <7 W Memory User Program Memory (nominal): 238 KB nonvolatile RAM Data Storage (nominal) Internal: 50 traces, 8 states External Memory Cards: HP 85700A (32 KB), 24 traces or 32 states HP 85702A (128 KB), 99 traces or 128 states Video Cassette Recorder: Continuous video recording of display supported through composite video output Size (nominal, without handle, feet, or cover): 325 mm W x 163 mm H x 427mm D Weight: 16.4 kg
Option 010 and 011 Built-In Tracking Generators
Frequency Range Opt 010: 9 kHz to 2.9 GHz Output Level Range Opt 010: -1 to 66 dBm Resolution: 0.1 dB Absolute Accuracy: ±0.5 dB Vernier Range: 9 dB Accuracy: ±0.8 dB Output Flatness: ±2 dB, >10 MHz Spurious Output Harmonic Spurs: -1 dBm output; <-25 dBc Nonharmonic Spurs: <-30 dBc Dynamic Range (characteristic, max output level - TG feedthrough) Opt 010: 111 dB, >400 kHz Power Sweep Range Opt 010: -66 dBm to -1 dBm in 8 dB increments Resolution: 0.1 dB
If you have Adobe's Acrobat Reader already available on your system, please click on the icon provided below to print or view the specifications.
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader, and then click on the icon below.
HP 8596E Portable Spectrum Analyzer, 9 kHz to 12.8 GHz
General Options
Opt 004 Precision Frequency Reference
Opt 009 Lo and Sweep + Tune
Opt 015 Soft Tan Carrying/Operating Case
Opt 016 Soft Yellow Carrying/Operating Case
Opt 040 Front Panel Protective Cover With Storage
Opt 041 HP-IB and Parallel Printer Interfaces
Opt 042 Protective Soft Carrying Case/Backpack
Opt 043 RS-232 and Parallel Printer Interfaces
Opt 101 Fast Time Domain Sweeps and Analog + Display
Opt 102 AM/FM Demodulator and TV Sync Trigger (TV Sync requires Opt 101)
Opt 130 Narrow Resolution Bandwidths (30 to 300 Hz and 200 Hz EMI)
Opt 140 Narrow Bandwidths and Precision Frequency Reference
Opt 301 TV Sync Trigger, Fast Time Domain Sweeps, AM/FM Demodulator,
Analog + Display
Opt 908 Rackmount Kit without Handles
Opt 909 Rackmount Kit with Handles
Communications Bundling
Opt BD0 CDMA Bundle
Opt 004 Precision Frequency Reference
Opt 053 Improved Amplitude Accuracy for CDMA
Opt 105 Time-Gated Spectrum Analysis
Opt 151 DSP, Fast ADC and Digital Demodulator
Opt 160 PDC/PHS/NADC/CDMA FW for Opt 151 HW
85725C CDMA Test Personality for 8590 E-Series
Opt BD1 GSM Bundle
Opt 004 Precision Frequency Reference
Opt 105 Time-Gated Spectrum Analysis
Opt 151 DSP, Fast ADC and Digital Demodulator
Opt 163 GSM/DCS Firmware for Phase/Frequency Error
85727A GSM Multi-Band Transmitter Measurement Personality
Opt BD2 TDMA/NADC Bundle
Opt 004 Precision Frequency Reference
Opt 050 Improved Amplitude Accuracy for NADC/PCS
Opt 105 Time-Gated Spectrum Analysis
Opt 151 DSP, Fast ADC and Digital Demodulator
Opt 160 PDC/PHS/NADC/CDMA FW for Opt 151 HW
85718B NADC/PCS-TDMA Measurement Personality
Opt BD3 PDC Bundle
Opt 004 Precision Frequency Reference
Opt 051 Improved Amplitude Accuracy for PDC
Opt 105 Time-Gated Spectrum Analysis
Opt 151 DSP, Fast ADC and Digital Demodulator
Opt 160 PDC/PHS/NADC/CDMA FW for Opt 151 HW
85720C BDC Test Personality for 8590 E-Series
Opt BD4 PHS Bundle
Opt 004 Precision Frequency Reference
Opt 052 Improved Amplitude Accuracy for PHS Band
Opt 105 Time-Gated Spectrum Analysis
Opt 151 DSP, Fast ADC and Digital Demodulator
Opt 160 PDC/PHS/NADC/CDMA FW for Opt 151 HW
85726B PHS Measurement Personality for 8590 E-Series
Component Test Options
Opt 010 Tracking Generator (9 kHz to 2.9 GHz)
Opt 119 Noise Figure
Cable TV Options
Opt 011 Tracking Generator (75 ohm)
Opt 107 TV Receiver Video Tester
Opt 180 TV Picture NTSC/PAL/SECAM
Opt 711 50/75 ohm Matching Pad/100 Vdc Block
Communications Options
Opt 012 Source for DECT Receiver Test
Opt 050 Improved Amplitude Accuracy (NADC - TDMA bands)
Opt 051 Improved Amplitude Accuracy for PDC Bands
Opt 052 Inproved Amplitude Accurancy for PHS Band
Opt 053 Improved Amplitude Accuracy for CDMA Bands
Opt 105 Time-Gated Spectrum Analysis
Opt 110 CT2 Demodulator
Opt 111 Group Delay and Amplitude Flatness
(also requires the HP 11770A Link Measurement Personality)
Opt 112 DECT Demodulator
Opt 151 DSP, FAST ADC, and Digital Demodulator
Opt 160 PDC, PHS, NACD, and CDMA Firmware for Option 151
Opt 163 GSM/DCS1800 Firmware for Option 151
EMC Options
Opt 103 Quasi-Peak Detector, AM/FM Demodulator
Warranty and Support Options
Opt 0Q8 Factory Service Training
Opt UK6 Commercial Calibration Certificate with Test Data
Opt AB* Quick Reference Guide in Local Languages
Opt W30 Two Additional Years Return-to-HP Service
Opt W32 Two Additional Years Return-to-HP Calibration
Opt 915 Component Level Information and Service Guide
Most options can be retrofitted. Please contact your local
HP sales representative.
Application Measurement Cards/Personalities
HP 85700A Blank 32-KB Memory Card
HP 85702A Blank 128-KB Memory Card
HP 11770A Link Measurement Personality
HP 85712D EMC Measurement Personality
HP 85713A Digital Radio Measurement Personality
HP 85714A Scalar Measurement Personality
HP 85715B GSM Measurement Personality
HP 85717A CT2-CAI Measurement Personality
HP 85718B NADC-TDMA Measurement Personality
HP 85719A Noise Figure Measurement Personality
HP 85720C PDC Measurement Personality
HP 85721A Cable TV Measurement Personality
HP 85722B DCS1800 /PCS1900 Measurement Personality
HP 85723A DECT Measurement Personality
HP 85724A Broadcast Measurement Personality
HP 85725C CDMA Measurement Personality
HP 85726B PHS Measurement Personality
HP 85727A GSM Multi-band Measurement Personality
HP 85921A Cable TV PC Software for HP 85721A
Some measurement personalities are not supported by all HP 8590
series models.
For complete information, please contact your local HP sales
representative.
Available accessories for this product include:
HP 8590 E-Series Portable Spectrum Analyzers, Technical Specifications
HP 8590L Series Portable Spectrum Analyzers, Product Overview
HP 8590 E-Series Spectrum Analyzers and the Options and Attachments that are Compatible with them, Configuration Guide
| If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
|
To help you make the right product choicesRelated Information:
Printer Compatibility Guide for Network and Spectrum Analyzers
Related HP 8590 E-Series Portable Spectrum Analyzer Family product datasheets:
Related product families available online:

Page Updated: Thursday November 12 21:44:42 UTC 1998