HP 8657B Option 022 0.3 GMSK Modulated Synthesized Signal Generator |
The HP 8657B Option 022 signal generator provides 0.3 Gaussian
Minimum Shift Keying (0.3 GMSK) modulation for testing receivers
designed for the Global System for Mobile Communications (GSM)
Pan-European Digital Cellular Radio System and the Personal
Communication Network (PCN). This option contains the necessary
premodulation filtering and signal-processing circuitry to generate
precise 0.3 GMSK modulation over the entire 520 to 2060 MHz and 10 to
130 MHz frequency bands. The HP 8657B Option 022 is also a versatile
signal generator offering a variety of features, such as simultaneous
and mixed modulation combinations of AM and FM, as well as a carrier
phase adjust capability that allows you to characterize phase-sensitive
devices. The low residual FM and excellent phase noise performance of
this signal generator makes it ideal for many in-channel and even
out-of-channel receiver tests. It offers a wide output range, +13 to
-143.5 dBm with superior level accuracy of 1.0 dB.
Frequency Specifications
Range: 100 kHz to 2060 MHz Resolution: 1Hz Timebase aging rate: ±2 ppm/year (typ.) Option 001: 1 x 10e-9 parts/day after 45 days (typ) Switching speed (w/i 100 Hz): <35 ms typ. at 25C)
Spectral Purity Specifications
SSB phase noise (fc=500 MHz, 20 kHz offset): <-130 dBc/Hz Nonharmonics (>5 kHz offset, CW): <-60 dBc, <1030 MHz <-54 dBc, >=1030 MHz Harmonics (at levels <=+7 dBm): <-30 dBc, <1030 MHz <-25 dBc, >=1030 MHz Subharmonics None, 100 kHz to 1030 MHz <-35 dBc, 1030 to 2060 MHz Residual FM (0.3 to 3 kHz, CW): <3 Hz rms (<6 Hz >1040 MHz). <
Output Specifications
Range: +13 to -143.5 dBm into 50 ohms, +10 dBm, <1030 MHz w/Opt 003 Resolution: 0.1 dB Absolute Accuracy: < ±1 dB, output +3.5 to -127 dBm < ±1.5 dB, output >=+ 3.5 dBm Reverse Power Protection: 50 W
0.3 GMSK Digital Modulation Mode Specifications
Frequency Range Date Normal: 520 to 2060 MHz Date Inverted: 10 to 130 MHz Harmonics (fc <1030 MHz): <-30 dBc Non-Harmonic Spurious (>150 kHz offset): <-50 dBc Noise Floor: <-100 dBc/Hz Modulation Format: 0.3 GMSK Pre-modulation Filter: Gaussian LPF Bandwidth x Data Rate (BT): 0.3 Data Rate: 270.833 kHz (±1 kHz) Modulation Phase Error: (890-960 MHz, 10-130 MHz): <3° rms (1° typ.) <8° peak (5° typ.) (1030 to 2060 MHz): <3.5° rms (1.5° typ.) <9° peak (1.5° typ.) Frequency Error (fc <1030 MHz): 10 Hz (fc >1030 MHz): 20 Hz Inputs: Serial data and clock Outputs: Baseband 0.3 GMSK I and Q signals
Frequency Modulation Specifications
Maximum peak deviation: 50 kHz, fc <1040 MHz 400 kHz, fc 1040 to 2060 MHz Resolution: 100 Hz, <1040 MHz, dev <20 kHz 200 Hz, >1040 MHz, dev <20 kHz Bandwidth (1 dB): dc to 50 kHz Indicator accuracy: <±5% of setting Distortion: <0.5% THD + noise (internal rates, >=6kHz peak deviation for >=3 kHz peak deviation) fc >=1040 MHz
Amplitude Modulation Specifications
Depth (output at <=+7 dBm): 0 to 100% fc >=400kHz Resolution: 1% Bandwidth (1 dB): 20 Hz to 40 kHz Accuracy (internal rates): < ±(2% + 6% of setting) (<90% AM <+7 dBm) Distortion: <1.5%, <1030 MHz (0 to 30% AM, internal <4%, >1030 MHz rates, level < +7 dBm)
Pulse Modulation Specifications
On/Off ratio (Option 003): >70 dB, fc >=130 MHz, >95 dB, fc>=1030 MHz Rise/fall time, 10% to 90%: <35 ns, fc>=130 MHz, <50 ns, fc>=1030 MHz Repetition rate: dc to 30 MHz, typical Duty cycle: 0% to 100%
General Specifications
Remote Programming Interface: HP-IB (HP's implementation of IEEE-488) IEEE-488 functions: SH0, AH1, T0, L2, SR0, RL1, PP0, DC1, DT0, C0, E1 Save/recall/sequence registers: 100 nonvolatile registers to save front-panel settings Operating temperature: 0° to 55°C 0.3 GMSK Modulation: +15°C to 35°C Power requirements: 100 V, 120 V, 220 V or 240 V (+5, -10%) from 48 to 440 Hz: 200 VA maximum 0.3 GMSK Modulation: 90 TO 264 V from 48 to 66 Hz; 75 VA maximum Size: 133 mm H x 425 mm W x 574 mm D (5.25 in x 16.75 in x 22.6 in) 0.3 GMSK Modulation: 44 mm H x 425 mm W x 422 mm D (1.75 in x 16.75 in x 17 in) Weight: 20.5 kg (45 lb) 0.3 GMSK Modulation: 4 kg (9 lb)
HP 8657B Opt 022 0.3 GMSK Modulated Synthesized Signal Generator Opt 001 High-Stability Timebase Opt 002 RF Connectors on Rear Panel Only Opt 003 Pulse Modulation Opt H60 Pulse Modulation, Frequencies to 1040 MHz Opt 907 Front Handle Kit (5061-9689) Opt 908 Rack Flange Kit (5061-9677) Opt 910 Extra Operation/Calibration and Two Service Manuals Opt 915 Add Service Manual Opt +W30 Three-year repair service Opt +W32 Three-year Calibration Service
Page Updated: Thursday June 19 16:21:56 UTC 1997