HP 8719D Microwave Vector Network Analyzer, 50 MHz to 13.5 GHz |
The HP 8719D vector network analyzer characterizes RF and microwave
components down to 50 MHz and up to 13.5 GHz. This analyzer includes a
fast-sweeping synthesized source, S-parameter test set, tuned receiver,
and large color display in a single package. The HP 8719D is an ideal
choice for cost- and space-conscious engineers in research and
development, manufacturing, incoming inspection, or quality assurance.
High source power and high receiver sensitivity combine to give the HP
8719D 100 dB of dynamic range. Choose the optional high-power test and
insert a booster amplifier to provide up to 20 watts at the test port,
and safely measure 20 watts at the receiver port. The serial and
parallel interfaces support modern printers and plotters, and the
built-in 3.5" floppy disk drive supports both DOS and LIF formats.
Source Minimum Frequency: 50 MHz Maximum Frequency: 13.5 GHz Frequency Resolution: 1 Hz Frequency Accuracy: 10 ppm Output Maximum Power: +5 dBm With Opt 007: +10 dBm Minimum Power: -70 dBm With Opt 007: -65 dBm Power Resolution: 0.01 dB Power Flatness: ±2 dB Power Sweep Range: 20 dB Receiver Receiver Sensitivity >2 GHz: -95 dBm With Opt 012: -123 dBm System Dynamic Range >2 GHz: 100 dB With Opt 007: 105 dB Test Port Connector: 3.5 mm Typical Measurement Rate (201 point sweep, swept mode) 1-port cal, narrow band sweep: 0.9 ms/point 2-port cal, narrow band sweep: 2.7 ms/point 1-port cal, full span sweep: 2.1 ms/point 2-port cal, full span sweep: 5.4 ms/point Physical Characteristics Size: 425 mm W x 222 mm H x 457 mm D (16.75 in x 8.75 in x 18.0 in), excluding connectors. Weight Net: 25 kg (54 lb) Shipping: 28 kg (61 lb) Data applies at 23°C ±3°. See product literature for total measurement uncertainty after error correction.
HP 8719D Microwave Vector Network Analyzer, 50 MHz to 13.5 GHz Opt 007 Mechanical Transfer Switch Opt 010 Time Domain Capability Opt 012 Direct Sampler Access Opt 085 High Power S-Parameter Test Set Modification Opt 089 Frequency Offset Mode Opt 1BN Mil Std 45662A Calibration Certificate Opt 1BP Mil Std 45662A Calibration with Test Data Opt 1CM Adds Rack Mount Flange Kit without Handles Opt 1CP Adds Rack Mount Flange Kit with Handles Opt 1D5 High-Stability Frequency Reference Opt 400 Adds Fourth Sampler and TRL Calibration Firmware HP 8719DX Microwave Vector Network Analyzer Configured for Non-Coaxial Applications. Includes the standard HP 8719D analyzer with options 010, 012, 1D5, and 400. Opt 089 Frequency Offset Mode Opt 1BN Mil Std 45662A Calibration Certificate Opt 1BP Mil Std 45662A Calibration with Test Data Opt 1CM Adds Rack Mount Flange Kit without Handles Opt 1CP Adds Rack Mount Flange Kit with Handles Configure a complete measurement system with test port cables, calibration kits, verification kits, and adapters. Waveguide calibration kits are available in X, P (Ku), K, and R (Ka) bands, covering 8.2 to 40 GHz. The HP 8720 family network analyzers use the same precision calibration standards and rugged flexible cables as the industry-standard HP 8510. Information Options Opt 0BW Adds Service Guide Opt 0BV Adds Component-Level Information Package Opt 0BX Adds Service Guide and Component-Level Information Package Opt 0B0 Deletes all User and Programming Guides Opt AV8 Adds Extra User and Programming Guides Opt ABF Adds French Quick Reference Guide Opt ABJ Adds Japanese Quick Reference Guide Service Options Opt 0Q8 Includes Factory-Delivered Service Training Opt W08 Converts One Year On-Site Repair Warranty to Three Year Return-to-HP Repair Warranty Opt W30 Adds Two Years of Return-to-HP Repair Opt W31 Adds Two Years of On-Site Repair Opt W32 Adds Three Years of Return-to-HP Calibration Opt W34 Adds Three Years of Return-to-HP Standards Compliant Calibration Opt W50 Adds Four Years of Return-to-HP Repair Opt W51 Adds Four Years of On-Site Repair Opt W53 Adds Five Years of Return-to-HP Standards Compliant Calibration Network Analyzer Upgrade Kits Order HP 8719DU plus the upgrade option designation: Opt 007 Mechanical Transfer Switch Opt 010 Time Domain Capability Opt 012 Direct Sampler Access Opt 020 Adds 20 GHz operation. Includes installation at an HP service center. Opt 040 Adds 40 GHz operation. Includes installation at an HP service center. Opt 085 High Power S-Parameter Test Set Modification Opt 089 Frequency Offset Mode Opt 1D5 Adds High-Stability Frequency Reference Opt 400 Adds Fourth Sampler and TRL Calibration Firmware HP 86382B (HP 8719C to 8720C) includes installation Opt N01 (HP 8719C to 8722C) return-to-HPHP 8719D/8720D/8722D Vector Network Analyzers Technical Specifications
If you do not have the Adobe Acrobat Reader necessary for viewing this documentation, download your Free Acrobat Reader now. |
![]() |
All orders include the following:
Included with a standard network analyzer is an installation and
quick start guide, a user's guide, a quick-reference guide, a
programmer's guide and example programs disk, a bandpass filter test
device, and a 1-year on-site service warranty (which may be converted
to a 3-year return-to-HP service warranty).
Page Updated: Thursday June 19 16:16:57 UTC 1997