HP 871XC Bench Sweep with Structural Return Loss and Fault Location (Option 100)

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
Today's expanding cable industry demands reliable, efficient and fast installation. Our bench sweep with Option 100 lets you test spools of cable quickly, accurately and repeatably. Comprehensive cable testing demands measuring loss, impedance, structural return loss (SRL) and fault location. We deliver all these capabilities and more in one easy-to-use instrument. Cable that doesn't meet specs is an expensive problem for manufacturers, installers and maintainers. Option 100 for the HP 871XC verifies manufacturers' data and fully tests cable that may have suffered invisible damage during shipment.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Source Specifications

HP 8711C/8712C: 300 kHz to 1.3 GHz HP 8713C/8714C: 300 kHz to 3.0 GHz

Receiver Specifications

Directivity: 40 dB (based on system directivity after calibration)

Fault Location Charactertistics

Range: 10,000 m (32,000 feet) Resolution: as low as 0.195% of range Corrections: one-port calibration cable loss cable velocity factor automatic cable calibration multi-bump correction

SRL Characteristics

Frequency Response Resolution: frequency span/trace points Impedance Automatic: average impedance measured and displayed by analyzer Manual Entry: average impedance manually entered by the user Connector Compensation Connector C: ±1 pF Connector Length: 0 to 200 mm (7.87 inches) (reflection port extension)


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 871XC     Bench Sweep with Structural Return Loss and Fault Location (Option 100)

Order
HP 8711C Opt 100 Structural Return Loss and Fault Location
HP 8712C Opt 100 Structural Return Loss and Fault Location
HP 8713C Opt 100 Structural Return Loss and Fault Location
HP 8714C Opt 100 Structural Return Loss and Fault Location

Retrofit Options
Option 100 can be installed in all existing HP 8711B, 8712B, 8713B,
and 8714B instruments.  Order retrofit part number 08712-60013.

Option 100 is also compatible with HP 8711A serial number 802 and above.
Order retrofit part number 08711-60063.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

RF Economy Network Analyzers, Technical Specifications
HP 871XC Configuration Guide

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right instrument choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


Related HP Cable TV Test Equipment product datasheets:

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Monday October 05 19:06:45 UTC 1998