HP 8720D Microwave Vector Network Analyzer Family

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
New enhancements now provide up to 7 times faster measurement speed!

Solve tough measurement problems with easy-to-use integrated microwave vector network analyzers. The HP 8720D vector network analyzer family combines a fast synthesized source, tuned receiver, and S-parameter testset in a single instrument. These instruments quickly and accurately measure magnitude, phase, and group delay of all four S-parameters, plus the absolute output power of microwave components.

The HP 8720D analyzers have the performance and flexibility to solve difficult measurement problems and cut test times, all at an attractive cost.

Electronic calibration (ECal) provides fast and simple calibration with a single connection, using the HP 85097A ECal PC Interface Kit and appropriate HP 85060 series calibration modules.


This product family includes


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Source

Minimum Frequency:           50 MHz
Maximum Frequency
   HP 8719D:                 13.5 GHz
   HP 8720D:                 20 GHz
   HP 8722D:                 40 GHz
Frequency Resolution:        1 Hz
Frequency Accuracy:          10 ppm

Output
                             8719D/20D          8722D
Maximum Power:               +5 dBm             -10 dBm
   With Opt 007:             +10 dBm            -5 dBm
Minimum Power:               -70 dBm            -75 dBm
   With Opt 007:             -65 dBm            -70 dBm
Power Resolution:            0.01 dB            0.01 dB
Power Flatness:              ±2 dB              ±3 dB
Power Sweep Range:           20 dB              15 dB

Receiver
                             8719D/20D          8722D
Receiver Sensitivity
   >2 GHz:                   -95 dBm            -92 dBm
   With Opt 012:             -123 dBm           -120 dBm
System Dynamic Range
   >2 GHz:                   100 dB             82 dB
   With Opt 007:             105 dB             84 dB
Test Port Connector:         3.5 mm             2.4 mm

Typical Measurement Rate (201 point, narrow band sweep)
1-port cal, Swept Mode:      93 ms
1-port cal, Stepped Mode:    523 ms
2-port cal, Swept Mode:      173 ms
2-port cal, Stepped Mode:    1053 ms

Physical Characteristics
Size:                        425 mm W x 222 mm H x 457 mm D
                             (16.75 in x 8.75 in x 18.0 in),
                             excluding connectors

Net Weight:                  25 kg (54 lb)
Shipping Weight:             28 kg (61 lb)

Data applies at 23 °C ± 3 °C. See product literature for
total measurement uncertainty after error correction.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8719D/8720D/8722D Vector Network Analyzers Configuration Guide ( PDF)
HP 8719D/8720D/8722D Vector Network Analyzers Technical Specifications ( PDF)

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8719D     Microwave Vector Network Analyzer, 50 MHz to 13.5 GHz
HP 8720D     Microwave Vector Network Analyzer, 50 MHz to 20 GHz
HP 8722D     Microwave Vector Network Analyzer, 50 MHz to 40 GHz
   Opt 007   Mechanical Transfer Switch
   Opt 010   Time Domain Capability
   Opt 012   Direct Sampler Access
   Opt 085   High Power S-Parameter Test Set Modification
   Opt 089   Frequency Offset Mode
   Opt 1BN   Mil Std 45662A Calibration Certificate
   Opt 1BP   Mil Std 45662A Calibration with Test Data
   Opt 1CM   Adds Rack Mount Flange Kit without Handles
   Opt 1CP   Adds Rack Mount Flange Kit with Handles
   Opt 1D5   High-Stability Frequency Reference
   Opt 400   Adds Fourth Sampler and TRL Calibration Firmware

Configure a complete measurement system with test port cables,
calibration kits, verification kits, and adapters.  Waveguide
calibration kits are available in X, P (Ku), K, and R (Ka) bands,
covering 8.2 to 40 GHz.  The HP 8720 family network analyzers use the
same precision calibration standards and rugged flexible cables as
the industry-standard HP 8510.

Information Options
   Opt 0BW   Adds Service Guide
   Opt 0BV   Adds Component-Level Information Package
   Opt 0BX   Adds Service Guide and Component-Level Information Package
   Opt 0B0   Deletes all User and Programming Guides
   Opt AV8   Adds Extra User and Programming Guides
   Opt ABF   Adds French Quick Reference Guide
   Opt ABJ   Adds Japanese Quick Reference Guide

Service Options
   Opt 0Q8   Includes Factory-Delivered Service Training
   Opt W01   Converts Three Year Return-to-HP Repair Warranty to
             One Year On-Site Repair Warranty
   Opt W32   Adds Three Years of Return-to-HP Calibration
   Opt W34   Adds Three Years of Return-to-HP Standards Compliant
             Calibration
   Opt W50   Adds Two Years of Return-to-HP Repair
   Opt W52   Adss Five Years of Return-to-HP Calibration
   Opt W54   Adds Five Years of Return-to-HP Standards Compliant
             Calibration

Network Analyzer Upgrade Kits
Order HP 8719DU, 8720DU, or 8722DU plus the upgrade option designation:
   Opt 000   Performance Upgrade Kit.  Provides new processor board
             for faster measurements and new firmware features for
             analyzers with firmware revision under 7.0.  Includes
             installation at an HP service center.
   Opt 007   Mechanical Transfer Switch
   Opt 010   Time Domain Capability
   Opt 012   Direct Sampler Access
   Opt 020   Adds 20 GHz operation. Includes installation at
             an HP service center. For HP 8719DU only.
   Opt 040   Adds 40 GHz operation. Includes installation at
             an HP service center. For HP 8719DU or 8720DU only.
   Opt 085   High Power S-Parameter Test Set Modification
   Opt 089   Frequency Offset Mode
   Opt 099   Firmware Upgrade Kit
   Opt 1D5   Adds High-Stability Frequency Reference
   Opt 400   Adds Fourth Sampler and TRL Calibration Firmware
HP 86382B    Upgrade HP 8719C to HP 8720C: incl. installation
HP 86382C    Upgrade HP 8720C to HP 8722C: incl. installation





All orders include the following:


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

Related Information:

Related product groups available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday January 29 00:06:28 UTC 1999