HP 8903B 20 Hz to 100 kHz Audio Analyzer

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 8903B audio analyzer provides unparalleled versatility and performance for audio measurements from 20 Hz to 100 kHz. The HP 8903B combines the functionality of a low-distortion audio source, high-performance distotion analyzer, frequency counter, ac voltmeter, dc voltmeter, and SINAD meter into one compact package. With microprocessor control of source and analyzer, the HP 8903B can perform stimulus-response measurements (such as signal-to-noise ratio and swept distortion) automatically with no additional equipment. For ease of use, most measurements on the HP 8903B are made with only one or two keystrokes. The HP 8903B automatically tunes and autoranges for maximum accuracy and resolution. For quick identification of input signals, the analyzer counts and displays the input frequency in all ac measurement modes.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

System Specifications

Distortion Residual Distortion and Noise(the higher of): 80 kHz BW: -80 dB (0.01%) or 17 uV, 20 Hz to 20 kHz 500 kHz BW: -70 dB (0.032%) or 50 uV, 20 Hz to 50 kHz -65 dB (0.056%) or 50 uV, 50 kHz to 100 kHz Signal-to-Noise Frequency Range: 50 Hz to 100 kHz Display Range: 0 to 99.99 dB Accuracy: +/- 1 dB Input Voltage Range: 50 mV to 300 V Residual Noise(the higher of): - 85 dB or 17 uV, 80 kHz BW; - 70 dB or 50 uV, 500 kHz BW

Source Specifications

Frequency Range: 20 Hz to 100 kHz Resolution: 0.3% Accuracy: 0.3% of setting Output Level Range: 0.6 mV to 6 V open circuit Resolution: 0.3% or better Accuracy:(open circuit) 2% of setting 60 mV to 6V, 20 Hzto 50 kHz; 3% of setting 6 mV to 6 V, 20 Hz to 100 kHz; 5% of setting 0.6 to 6 mV, 20 Hz to 100 kHz Flatness(1 kHz reference): +/- 0.7% (+/- 0.06 dB), 20 Hz to 20 kHz; +/- 2.5% (+/- 0.22 dB), 20 Hz to 100 kHz Distortion and Noise(the higher of): 80 kHz BW: -80 dB(0.01%) or 15 uV, 20 Hz to 20 kHz 500 kHz BW: -70 dB (0.032%) or 38 uV, 20 Hz to 50 kHz -65 dB (0.056%) or 38 uV, 50 to 100 kHz Impedence: 600 ohms +/- 1% or 50 ohms, +/- 2%, front-panel selectable (HP-IB programmable) Sweep Mode: Log sweep with up to 500 points per decade or 255 points total between entered start and stop frequencies

Analyzer Specifications

Distortion Fundamental Frequency Range: 20 Hz to 100 kHz Display Range: 0.001% to 100% (-99.99 to 0 dB) Accuracy: +/- 1 dB, 20 Hz to 20 kHz; +/- 2 dB, 20 Hz to 100 kHz Input Voltage Range: 50 mV to 300 V Residual Distortion and Noise:(the higher of) 80 kHz BW: -80 db (0.01%) or 15 uV, 20 Hz to 20 kHz 500 kHz BW: -70 dB (0.032%) or 45 uV, 20 Hz to 50 kHz -65 db (0.056%) or 45 uv, 50 to 100 kHz Supplemental Charateristics: 3 dB Measurement Bandwidth: 10 Hz to 500 kHz Detection: True rms or rms calibrated average SINAD Fundamental Frequency Range: 20 Hz to 100 kHz Display Range: 0 to 99.99 dB Residual Distortion and Noise: Same as listed under distortion Accuracy: +/-1 dB, 20 Hz to 20 kHz; +/-2 dB, 20 Hz to 100 kHz Input Voltage Range: 50 mV to 300 V Supplemental Characteristics: Detection: True rms or rms-calibrated average Tuning: Notch filter is tuned to the internal source frequency. . Frequency Measurement Measurement Range: 20 Hz to 150 kHz (20 Hz to 100 kHz in distortion and SINAD modes) Resolution: 5 digits (0.01 Hz for input frequencies < 100 Hz) Accuracy: +/- (0.004% + 1 digit) Sensitivity: 50 mV in distortion and SINAD modes, 5.0 mV in ac level and signal-to-noise modes Analyzer Input Input Type: Balanced (full differential) Input Impedence: 100 k ohms +/- 1% shunted by <300 pF, each side to ground. (In dc-level mode the input resistance is 101 k ohms +/-1%) Max Input:(maximum peak input voltage, any combination of ac/dc) 425 V peak, applied differentially or between either input to ground CMRR: > 60 dB, 20 Hz to 1 kHz, V(in) <2V; > 45 dB, 20 Hz to 1 kHz; > 30 dB, 20 Hz to 20 kHz


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8903B	Audio Analyzer

   Opt 001	Input/Ouput Connectors on Rear Panel Only

   Opt 010 or 050	400 Hz High-Pass Filter
   Opt 011 or 051	CCITT Weighting Filter
   Opt 012 or 052	CCIR Weighting Filter
   Opt 013 or 053	C-Message Weighting Filter
   Opt 014 or 054	CCIR/ARM Weighting Filter
   Opt 015 or 055	"A" Weighting Filter

   Opt 907	Front handle Kit (5061-9689)
   Opt 908	Rack Flange Kit (5061-9677)
   Opt 909	Rack Flange Kit (5061-9683) with Front Handles

   Opt 910	Two sets of Operation/Calibration (08903-90079)
		and Service Manuals (08903-90062)
   Opt 915	Service Manuals (08903-90062)

   Opt W30	Extended Repair Service
   Opt W32	Calibration Service


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday February 05 07:16:26 UTC 1999