HP 8903E 20 Hz to 100 kHz Distortion Analyzer

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 8903E distortion analyzer provides unparalled versatility and performance for audio measurements from 20 Hz to 100 kHz.The HP 8903E combines the functionality of a high performance distortion analyzer, frequency counter, ac voltmeter, dc voltmeter and SINAD meter into one compact package. (The HP 8903E has no source.) For ease of use, most measurements on the HP 8903E are made with only one or two keystrokes.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Analyzer Specifications

Distortion Fundamental Frequency Range: 20 Hz to 100 kHz Display Range: 0.001% to 100% (-99.99 to 0 dB) Accuracy: +/- 1 dB, 20 Hz to 20 kHz; +/- 2 dB, 20 Hz to 100 kHz Input Voltage Range: 50 mV to 300 V Residual Distortion and Noise:(the higher of) 80 kHz BW: -80 db (0.01%) or 15 uV, 20 Hz to 20 kHz 500 kHz BW: -70 dB (0.032%) or 45 uV, 20 Hz to 50 kHz -65 db (0.056%) or 45 uv, 50 to 100 kHz Supplemental Charateristics: 3 dB Measurement Bandwidth: 10 Hz to 500 kHz Detection: True rms calibrated average SINAD Fundamental Frequency Range: 20 Hz to 100 kHz Display Range: 0 to 99.99 dB Residual Distortion and Noise: Same as listed under distortion Accuracy: +/-1 dB, 20 Hz to 20 kHz; +/-2 dB, 20 Hz to 100 kHz Input Voltage Range: 50 mV to 300 V Supplemental Characteristics: Detection: True rms or rms-calibrated average Frequency Measurement Measurement Range: 20 Hz to 150 kHz (20 Hz to 100 kHz in distortion and SINAD modes) Resolution: 5 digits (0.01 Hz for input frequencies < 100 Hz) Accuracy: +/- (0.004% + 1 digit) Sensitivity: 50 mV in distortion and SINAD modes Analyzer Input Input Type: Balanced (full differential) Input Impedence: 100 k ohms +/- 1% shunted by <300 pF, each side to ground. (In dc-level mode the input resistance is 101 k ohms +/-1%) Max Input:(maximum peak input voltage, any combination of ac/dc) 42 V peak, low side to ground 425 V peak, differentially or between either input to ground CMRR: > 60 dB, 20 Hz to 1 kHz, V(in) < 2V; > 45 dB, 20 Hz to 1 kHz; > 30 dB, 20 Hz to 20 kHz


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8903E	Distortion Analyzer
   Opt 001	Input/Output Connectors on Rear Panel Only

   Opt 010 or 050	400 Hz High-Pass Filter
   Opt 011 or 051	CCITT Weighting Filter
   Opt 012 or 052	CCIR Weighting Filter
   Opt 013 or 053	C-Message Weighting Filter
   Opt 014 or 054	CCIR/ARM Weighting Filter
   Opt 015 or 055	"A" Weighting Filter

   Opt 907	Front handle Kit (5061-9689)
   Opt 908	Rack Flange Kit (5061-9677)
   Opt 909	Rack Flange Kit (5061-9683) with
                 Front Handles

   Opt 910	Additional Operation and Calibration Manuals
                  (08903-90053)and Two Service Manuals (08903-90065)
   Opt 915	Adds Service Manual (08903-90065)

   Opt W30	Extended Repair Service
   Opt W32	Calibration Service


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

No literature is available online at this time.

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday February 05 07:16:28 UTC 1999