HP 8903E 20 Hz to 100 kHz Distortion Analyzer![]()
|
Analyzer Specifications
Distortion Fundamental Frequency Range: 20 Hz to 100 kHz Display Range: 0.001% to 100% (-99.99 to 0 dB) Accuracy: +/- 1 dB, 20 Hz to 20 kHz; +/- 2 dB, 20 Hz to 100 kHz Input Voltage Range: 50 mV to 300 V Residual Distortion and Noise:(the higher of) 80 kHz BW: -80 db (0.01%) or 15 uV, 20 Hz to 20 kHz 500 kHz BW: -70 dB (0.032%) or 45 uV, 20 Hz to 50 kHz -65 db (0.056%) or 45 uv, 50 to 100 kHz Supplemental Charateristics: 3 dB Measurement Bandwidth: 10 Hz to 500 kHz Detection: True rms calibrated average SINAD Fundamental Frequency Range: 20 Hz to 100 kHz Display Range: 0 to 99.99 dB Residual Distortion and Noise: Same as listed under distortion Accuracy: +/-1 dB, 20 Hz to 20 kHz; +/-2 dB, 20 Hz to 100 kHz Input Voltage Range: 50 mV to 300 V Supplemental Characteristics: Detection: True rms or rms-calibrated average Frequency Measurement Measurement Range: 20 Hz to 150 kHz (20 Hz to 100 kHz in distortion and SINAD modes) Resolution: 5 digits (0.01 Hz for input frequencies < 100 Hz) Accuracy: +/- (0.004% + 1 digit) Sensitivity: 50 mV in distortion and SINAD modes Analyzer Input Input Type: Balanced (full differential) Input Impedence: 100 k ohms +/- 1% shunted by <300 pF, each side to ground. (In dc-level mode the input resistance is 101 k ohms +/-1%) Max Input:(maximum peak input voltage, any combination of ac/dc) 42 V peak, low side to ground 425 V peak, differentially or between either input to ground CMRR: > 60 dB, 20 Hz to 1 kHz, V(in) < 2V; > 45 dB, 20 Hz to 1 kHz; > 30 dB, 20 Hz to 20 kHz
HP 8903E Distortion Analyzer Opt 001 Input/Output Connectors on Rear Panel Only Opt 010 or 050 400 Hz High-Pass Filter Opt 011 or 051 CCITT Weighting Filter Opt 012 or 052 CCIR Weighting Filter Opt 013 or 053 C-Message Weighting Filter Opt 014 or 054 CCIR/ARM Weighting Filter Opt 015 or 055 "A" Weighting Filter Opt 907 Front handle Kit (5061-9689) Opt 908 Rack Flange Kit (5061-9677) Opt 909 Rack Flange Kit (5061-9683) with Front Handles Opt 910 Additional Operation and Calibration Manuals (08903-90053)and Two Service Manuals (08903-90065) Opt 915 Adds Service Manual (08903-90065) Opt W30 Extended Repair Service Opt W32 Calibration Service
No literature is available online at this time.
Related product families available online:
Page Updated: Friday February 05 07:16:28 UTC 1999