HP 8921A Cell Site Test Set

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP 8921A cell site test set is a highly portable, integrated solution for the installation and maintenance of AMPS and TACS cell sites. The HP 8921A incorporates more than twenty powerful instruments into a compact, 38 pound package with options available for TDMA, CDMA, CDPD and PCS cell site test. The integral IBASIC controller in the HP 8921A runs the HP 11807B cell site test software to fully automate base station test and adjustment procedures for many applications. Automation combined with accurate measurements increases technician efficiency to speed installation and maintenance procedures.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Signal Generator

Frequency Range:
	250 kHz to 1000 MHz
Output Level Range:
	-137 to -19 dBm into 50 ohms
Output Level Accuracy:
	+/-1.8 dB (level >/= -127 dBm)
	Typically +/-1.0 dB for all levels
Harmonics:
	<-30 dBc
Non-Harmonic Spurious:
	<-60 dBc (at >5 kHz offset from carrier)

RF Analyzer:

Measurement Range: 400 kHz to 1000 MHz Level Range: RF In/Out: 1m W to 60 W continuous 100 W for 10 seconds/minute ANT In: -36 dBm to +20 dBm Frequency Measurement Accuracy: +/-1 Hz plus timebase accuracy Power Measurement Range: 30 MHz to 1000 MHz Power Measurement Accuracy: +/-5% of reading +/-1 mW (for inputs >/=200 mW at 25 degrees +/-10 degrees C)

Spectrum Analyzer

Frequency Range: 400 kHz to 1000 MHz Frequency Span/Resolution Bandwidth (coupled): Span Bandwidth <50 kHz 300 Hz <200 kHz 1 kHz <1.5 MHz 3 kHz <18 MHz 30 kHz >/=18MHz 300 kHz, Plus full span capability Display: Log with 10 dB/div, 2 dB/div, or 1 dB/div Display Range: 80 dB Reference Level Range: +50 to -50 dBm

AF Analyzer

Frequency Measurement Range: 20 Hz to 400 kHz Frequency Measurement Accuracy: +/- 0.02% plus resolution plus reference oscillator accuracy AC Voltage Measurement Range: 0 to 30 Vrms AC Voltage Measurement Accuracy: (20 Hz to 15 kHz, inputs >/=1 mV):+/-3% of reading DC Voltage Measurement Range: 100 mV to 42V DC Voltage Measurement Accuracy: +/- 1.0% of reading plus DC offset

General Specifications

Dimensions (HxWxD): HP 8921A: 188 x 330 x 456mm Weight: HP 8921A: 38 lbs.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

HP 8921A	Cell Site Test Set
   Opt 011	CCITT Filter
   Opt 020	Radio Interface Adapter
   Opt 042	Ericsson PCM Reference
   Opt 500      TDMA Cell Site Test System
   Opt 501      TDMA PCS Cell Site Test System
   Opt 502      CDPD MDBS Cell Site Test System
   Opt 503      TDMA/CDPD Cell Site Test System
   Opt 600	CDMA Cell Site Test System
   Opt 601      CDMA PCS Cell Site Test System
   Opt 602      CDPD MDBS Cell Site Test System
   Opt 603      CDMA/CDPD MDBS Cell Site Test System

   Opt W30	Three Year Return Repair Service
   Opt W50      Five Year Return Repair Service

HP 83236B       PCS Interface
   Opt AX4      Rack Flange Kit Without Handles
   Opt W30	Three Year Return Repair Service
   Opt W50      Five Year Return Repair Service

08920-61051 CRT Sunshade 08920-61060 Antenna 08920-61059 Microphone for HP 8921A 08920-80027 DC Battery Pack (24 volts) 08920-90033 HP 8921A Transit Case 08920-90141 HP 8921A Option 500/600 Transit Case 08920-90037 Assembly Level Repair Manual 1540-1130 HP 8921A Padded Carrying Case 08920-61147 HP 8921A Option 500/600 Padded Carrying Case 83201-90003 HP 83201A Assembly Level Repair Manual HP 83202A Base Station Connection Kits: These kits contain all of the necessary cables, connectors, and where required, interface/switch boxes to connect and fully automate base station testing with the HP 8921A/D Cell Site Test Set. Opt 040 Motorola Connection Kit* Opt 042 Ericsson Connection Kit Opt 043 AT&T Connection Kit Opt 044 GE and Northern Telecom Connection Kit


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Technical Specifications ( PDF)
Configuration Guide ( PDF)
RF Test Sets for Wireless Communications ( PDF)
Install and Optimize Cell Sites Faster - CDMA/TDMA/PCS ( PDF)
Call Analysis Logging and Monitoring Software ( PDF)
HP 892X IBASIC Programming Environment ( PDF)
HP 892X Programming Techniques ( PDF)
IBASIC Developers Tool Kit ( PDF)

If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

To help you make the right product choices

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Related product families available online:



Privacy Statement    Use of this site indicates that you accept the Terms of Use
Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

Page Updated: Friday February 05 07:16:41 UTC 1999