Signal Generator
Frequency Range: 250 kHz to 1000 MHz Output Level Range: -137 to -19 dBm into 50 ohms Output Level Accuracy: +/-1.8 dB (level >/=-127 dBm) Typically +/-1.0 dB for all levels Harmonics: <-30 dBc Non-Harmonic Spurious: <-60 dBc (at >5 kHz offset from carrier)
TDMA Signal Generator
HP 8921A Option 500, 503 or HP 8921A plus HP 83204A Option 001, 003 Output Level Range: RF In/Out:-22 dBm to -127 dBm Duplex: +4 dBm to -127 dBm Residual Error Vector Magnitude: <3.0% Residual Phase Error: <3 degrees Residual Magnitude Error: <3.0% IQ Origin Offset: <-30 dBc within +/-15 degrees C of last calibration Frequency Error: +/-4 Hz plus reference
RF Analyzer:
Measurement Range: 400 kHz to 1000 MHz Level Range: RF In/Out: 1 mW to 60 W continuous 100 W for 10 seconds/minute ANT In: -36 dBm to +20 dBm Frequency Measurement Accuracy: +/-1 Hz plus timebase accuracy Power Measurement Range: 30 MHz to 1000 MHz Power Measurement Accuracy: +/-5% of reading +/-1 mW (for inputs >/=200 mW at 25 degrees +/-10 degrees C)
TDMA Analyzer
8921A Option 500, 503 or HP 8921A plus HP 83204A Option 001, 003 Input Level Range: RF In/Out: 1 mW to 60 W (0 to +47.78 dBm) Antenna: -36 dBm to +16 dBm Residual Error Vector Magnitude: <2.0% Error Vector Magnitude Measurement Accuracy: 0.4% + 2% of reading I/Q Origin Offset Accuracy: +/-0.5 dB for values to -40 dBc Frequency Error Accuracy: +/-2 Hz plus reference
Spectrum Analyzer
Frequency Range: 400 kHz to 1000 MHz Frequency Span/Resolution Bandwidth (coupled): Span Bandwidth <50 kHz 300 Hz <200 kHz 1 kHz <1.5 MHz 3 kHz <18 MHz 30 kHz >/=18MHz 300 kHz, Plusfull span capability Display: Log with 10 dB/div,2 dB/div, or 1 dB/div Display Range: 80 dB Reference Level Range: +50 to -50 dBm
AF Analyzer
Frequency Measurement Range: 20 Hz to 400 kHz Frequency Measurement Accuracy: +/-0.02% plus resolution plus reference oscillator accuracy AC Voltage Measurement Range: 0 to 30 Vrms AC Voltage Measurement Accuracy: (20 Hz to 15 kHz, inputs >/=1 mV): +/-3% of reading DC Voltage Measurement Range: 100 mV to 42 V DC Voltage Measurement Accuracy: +/-1.0% of reading plus DC offset
CDPD Specifications
The following CDPD specifications apply when the HP 83204A option 002 or 003 is operating with the HP 8921A.
CDPD Signal Generator (at HP 8921A Duplex Out)
Output: Level Range and Level Accuracy: Same as HP 8921A Reverse Power: Sameas HP 8921A Frequency Range: Same as HP 8921A Frequency Accuracy: ±500Hz, typically ±50Hz Spectral Purity: Spurious Signals, Adjacent Channels: <-26 dBc Spurious Signals, First Alternate Channel: <-45 dBc Spurious Signals, Second Alternate Channel: < 60 dBc Switching Speed: Typically <150 msec to be within 1 kHz Transmitter On/Off Level and Timing: >15 dB down in <1msec Modulation Type: GMSK with BT=0.5 Modulation Accuracy: <5% error in modulation index
CDPD Analyzer
RF Frequency Range: Same as HP 8921A Input Level Range: Sameas HP 8921A RF Power Measurement: Accuracy: RF in/out: 5%, ±0.01 mW (at 25ˆ¯10°C) for single signal >200 mw, 10% over full temperature range Frequency Error Accuracy: Time base accuracy ±1 Hz Modulation Index Accuracy: <0.1% error in modulation index Adjacent Channel Power measurement floor: Typically -45 dBc Alternate Channel Power measurement noise floor: Typically -55 dBc for input levels > -34 dBm
HP 8921A Cell Site Test Set Opt 011 CCITT Filter Opt 020 Radio Interface Adapter Opt 042 Ericsson PCM Reference Opt 500 TDMA Cell Site Test System Opt 501 TDMA PCS Cell Site Test System Opt 502 CDPD MDBS Cell Site Test System Opt 503 TDMA/CDPD MDBS Cell Site Test System Opt W30 Three Year Return Repair Service Opt W50 Five Year Return Repair Service HP 83204A TDMA Cellular Adapter Opt 001 TDMA Cellular Adapter Opt 002 CDPD Cellular Adapter, upgradable to TDMA Opt 003 TDMA/CDPD Cellular Adapter Opt W30 Three Year Return Repair Service Opt W50 Five Year Return Repair Service Opt R13 CDPD Retrofit Kit for HP 83204A opt. 001 to Opt. 003 Opt R23 TDMA Retrofit Kit for HP 83204A Opt. 002 to Opt. 003 Opt R99 CDPD Software Revision Update Kit
Product Note
( PDF)
Product Overview
( PDF)
Brochure
( PDF)
Technical Specifications
( PDF)
CDPD Testing
( PDF)
Technical Specifications
( PDF)
If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. |
![]() |
Related product families available online:
Page Updated: Friday February 12 06:57:08 UTC 1999