HP E1364A VXI 16-Channel Form C Switch |
The HP E1364A 16-channel Form C Switch is a B-size, 1-slot, register-based VXI module. It uses latching armature relays, and is capable of carrying 1 Amp of current on a single channel. This versatile general-purpose switch is suitable for switching, scanning, control, or digital output applications.
This module contains positions for jumpers or resistors, allowing
each channel to optionally connect to internal +5 V or +12 V
supplies for digital output applications. Current on these supplies
should not exceed 1 A and 0.5 A, respectively, per switch. The
latching relays ensure all switches will remain in the same position
when power is removed. A terminal block is also included.
Note: Configuration software that allows you to easily select
compatible interfaces, controller platforms, and VXI test system
components is available on CD ROM. Order the
"Test System
and VXI Products Catalog and CD ROM" from
the Test & Measurement Catalogs available on this web site.
Input
DC: Maximum voltage (C to NC or NO or any terminal-to-chassis): DC: 250 V AC rms: 250 V AC peak: 354 V Maximum current (non-inductive, per switch): DC: 1 A AC rms: 1 A Maximum power: Per switch: DC: 40 W AC: 40 VA Per module: DC: 320 W AC: 320 VA
DC
Maximum thermal offset: 7 µV Closed channel resistance: Initial: <1.5 Ohm typ End of life: <3.5 Ohm Insulation resistance (between any two points): <=40°C, <=95% RH: -- <=40°C, <=65% RH: >10E7 Ohm <=25°C, <=40% RH: >10E8 Ohm
AC
Typical bandwidth (-3 dB): 10 MHz Crosstalk (dB, channel-to-channel): <10 kHz: -- <100 kHz: <-80 <1 MHz: -- <10 MHz: <-30 Closed channel capacitance: Ch-to-ch: <20 pF Ch-to-com: <20 pF
General Characteristics
Typical relay life (number of operations): No load: >10E6 Rated load: >10E5 Time to close or open a channel (register programming): 10.7 ms Power up/down states: all open, left in last state Connector type, wire size: Screw: >=16 AWG(1.5 mm)
VXI Characteristics
VXI device type: Register-based,A16, slave only Size: B Slots: 1 Connectors: P1 Shared memory: None VXI busses: None C-size compatibility: Requires E1403B
Instrument Drivers
Click here for driver availability and downloading.Command module firmware: ROM Command module firmware rev: A.01 I-SCPI Win 3.1: Yes I-SCPI Series 700: Yes C-SCPI LynxOS: Yes C-SCPI Series 700: Yes HP VEE Drivers: Yes VXIplug&play Win Framework: Yes VXIplug&play Win95/NT Framework: Yes VXIplug&play HP-UX Framework: No (not available at time of publication)
Module Current
IPM IDM +5 V: 0.1 0.01 +12 V: 0.24 0.01
Cooling/Slot
Watt/slot: 1.00 deltaP mm H2O: 0.02 Air flow liter/s: 0.10
HP E1364A VXI 16-Channel Form C Switch Opt 0B3 Service manual Opt W01 3-yr. return to HP to 1-yr. on-site warrantyHP E1364A Technical Specifications Datasheet
If you do not have the Adobe Acrobat Reader necessary for viewing this documentation, download your Free Acrobat Reader now. |
![]() |
Page Updated: Thursday June 19 16:15:52 UTC 1997