HP E1370A VXI Microwave Switch/Step Attenuator Driver


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Summary

The HP E1370A switch/step attenuator driver is a B-size, 2-slot, register-based VXI module. It provides room for you to install a single-pole multithrow microwave switch or a programmable step attenuator.

The HP 8766/7/8/9K single-pole, multithrow switches can be installed, providing 3-, 4-, 5-, or 6-throw switching. Alternatively, the HP 33320G/H, 33321G/H, 33322G/H, and 33323K step attenuators can be installed providing broadband accuracy, high repeatability over a long life, and rapid switching flexibility. Whichever device you choose, you must order each one separately.

This module contains the control, drive, and power circuitry for mounting and controlling the microwave switches or step attenuators. Additionally, it comes with a 14-pin DIP socket for connecting one microwave switch or step attenuator either in the module or remotely.

Cabling
For frequencies up to 18 GHz, use a good quality flexible cable and SMA connectors. For frequencies above 18 GHz, use semirigid type cable and APC 3.5 connectors.

C-size Adapter
For installation in a C-size mainframe, see the HP E1403B active adapter.


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Features

Note: Configuration software that allows you to easily select compatible interfaces, controller platforms, and VXI test system components is available on CD ROM. Order the "Test System and VXI Products Catalog and CD ROM" from the Test & Measurement Catalogs available on this web site.


[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Specifications


General

Switching dwell time: 35 ms
Driver output voltage(1): 5 V or 12 V 
Maximum external energizing voltage: 42 V
(1)Control circuit can switch max 1 A per switch. Max current also
depends on output capability of the mainframe.

Microwave Switches, Single-Pole Multi Throw

Configuration:
	HP 8766K: SP3T unterminated
	HP 8767K: SP4T unterminated
	HP 8768K: SP5T unterminated
	HP 8769K: SP6T unterminated
Connectors: APC-3.5 (SMA compatible) all switches. (Opt 002 deletes APC and adds SMA.)
Impedance: 50 Ohm
Frequency range: dc-26.5 GHz
Life and repeatability: 0.03 dB @ 1,000,000 cycles per section
Power average/peak: 1 W avg, 100 W peak (+7 Vdc) (nonswitching)
Repeatability: 0.03 dB max (typically 0.01 dB over 5 million switching cycles per section)
Max RF power: 1 W avg, 100 W peak (10 盜)

Programmable Step Attenuators

             Frequency 
Model        Range (GHz)    Atten/ Steps          Insertion Loss @0 dB      SWRMaximum
HP 33320G    DC-4           0-11/ 1 dB steps      0.6 dB + 0.09 dB/GHz      4 GHz: 1.5  
HP 33320H    DC-18          0-11/ 1 dB steps      0.6 dB + 0.09 dB/GHz      8 GHz: 1.5; 12.4 GHz: 1.6; 18 GHz: 1.9 
HP 33321G    DC-4           0-70/ 10 dB steps     0.4 dB + 0.07 dB/GHz      4 GHz: 1.35 
HP 33321H    DC-18          0-70/ 10 dB steps     0.4 dB + 0.07 dB/GHz      8 GHz: 1.35; 12.4 GHz: 1.5; 18 GHz: 1.7 
HP 33322G    DC-4           0-110/ 10 dB steps    0.6 dB + 0.09 dB/GHz 
HP 33322H    DC-18          0-110/ 10 dB steps    0.6 dB + 0.09 dB/GHz      8 GHz: 1.5; 12.4 GHz: 1.6; 18 GHz: 1.9 
HP 33323K    DC-26.5        0-90/ 10 dB steps     0.6 dB + 0.09 dB/GHz      6 GHz: 1.25; 12.4 GHz: 1.45; 18 GHz: 1.6; 26.5 GHz: 1.8
Note: SMA female connectors standard on all attenuators. 
See ordering information for other connectors.

VXI Characteristics

VXI device type:        Register-based, A16, slave only
Size:                   B
Slots:                  1 
Connectors:             P1
Shared memory:          None
VXI busses:             None
C-size compatibility:   Requires E1403B

Instrument Drivers

Click here for driver availability and downloading.
Command module 
 firmware:               ROM 
Command module 
 firmware rev:           A.01
I-SCPI Win 3.1:          Yes
I-SCPI Series 700:       Yes
C-SCPI LynxOS:           Yes
C-SCPI Series 700:       Yes
HP VEE Drivers:          Yes
VXIplug&play Win 
Framework:               No
VXIplug&play Win95/NT 
Framework:               No
VXIplug&play HP-UX 
Framework:     No (not available attime of publication)

Module Current

                IPM       IDM 
+5 V:           0.1       0

Cooling/Slot

Watt/slot:  5.00
deltaP mm H2O:  0.08
Air Flow liter/s:  0.50



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

Product Ordering Information

HP E1370A	VXI Microwave Switch/Step Attenuator Driver
   Opt      W01	3-yr. return to HP to 1-yr. on-site warranty

33320G		Programmable step attenuator, dc - 4 GHz
   Opt 008	dc ribbon cable, 8"  
   Opt 011	5 volt operation instead of std 24 volt 
   Opt 016	dc ribbon cable, 16"  
   Opt 020	Ribbon cable assembly, 233 mm long  
   Opt 890	Attenuator calibration data  
   Opt UKS	Certificate of calibration  

33320H		Programmable step attenuator, dc-18 GHz 
   Opt 008	dc ribbon cable, 8"  
   Opt 011	5 volt operation instead of std 24 volt 
   Opt 016	dc ribbon cable, 16"  
   Opt 020	Ribbon cable assembly, 233 mm long  
   Opt 890	Calibration data  
   Opt UKS	Certificate of calibration  

33321G		Programmable Step Attenuator  
   Opt 008	DC Ribbon Cable, 8"  
   Opt 011	Programmable Step Attenuator  
   Opt 016	DC Ribbon Cable, 16"  
   Opt 020	Ribbon Cable Option  
   Opt 890	Attenuator Calibration Data  
   Opt UKS	Certificateof calibration  

33321H		Programmable 10 dB OEM step attenuator  
   Opt 008	dc ribbon cable, 8"  
   Opt 011	5 volt operation instead of std 24-30 V 
   Opt 016	dc ribbon cable, 16"  
   Opt 020	Ribbon cable assembly, 233 mm long  
   Opt 890	Calibration data  
   Opt UKS	Certificate of calibration  

33322G		Programmable Step Attenuator  
   Opt 008	DC Ribbon Cable, 8"  
   Opt 011	Programmable Step Attenuator, 5volts  
   Opt 016	DC Ribbon Cable, 16"  
   Opt 020	Ribbon Cable Option  
   Opt 890	Calibration Data  
   Opt UKS	Certificate of calibration  

33322H		Programmable step attenuator; 110 dB max
   Opt 008	dc ribbon cable, 8"  
   Opt 011	5 volt operation instead of std 24 volt 
   Opt 016	dc ribbon cable, 16"  
   Opt 020	Ribbon cable assembly, 233 mm long  
   Opt 890	Calibration data  
   Opt UKS	Certificate of calibration  

33323K		Programmable Step Attenuator  
   Opt 008	8 inch Ribbon Cable  
   Opt 011	5 voltCoils  
   Opt 016	16 inch Ribbon Cable  
   Opt 020	Ribbon Cable Option  
   Opt 890	Calibration Data  
   Opt UKS	Certificate of calibration  

8766K		SP3T 50 Ohm Microwave Switch
   Opt 008	8-in ribbon cable
   Opt 011	5 volt operation

8767K		SP4T 50 Ohm Microwave Switch
   Opt 008	8-in ribbon cable
   Opt 011	5 volt operation

8768K		SP5T 50 Ohm Microwave Switch
   Opt 008	8-in ribbon cable
   Opt 011	5 volt operation

8769K		SP6T 50 Ohm Microwave Switch
   Opt 008	8-in ribbon cable
   Opt 011	5 volt operation

Documentation Available
Request the HP Microwave Test Accessories Catalog for additional information.

HPE1370A Technical Specifications Datasheet

If you do not have the Adobe Acrobat Reader necessary for viewing this documentation, download your Free Acrobat Reader now. Get Acrobat



[ Summary ][ Features ][ Specifications ][ Ordering ][ Assistance ]

To help you make the right instrument choices



Contact HP Test & Measurement. (c) Copyright 1994, 1995, 1996, 1997 Hewlett-Packard Company.

Page Updated: Thursday June 19 16:15:50 UTC 1997