HP E1421B 6-Slot, C-Size VXI Mainframe

[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]
The HP E1421B C-size, 6-slot VXI mainframe is a compact, cost-effective solution for configurations requiring fewer slots than the 13-slot HP E1401B C-size mainframe.

The smaller size and weight of the HP E1421B make it an excellent choice for either portable or rack-mount applications. The HP E1421B complies with the VXIbus Specification by providing injector surface rails used by the HP QUIC easy module insertion and extraction system.

HP has incorporated its industry-leading Pressurized Air Channel cooling system into the design of the HP E1421B. It ensures clean, uniform airflow to each module. For greater power supply serviceability, power input intake is through the rear of the mainframe. Airflow is through the right side and exhausts through the left.

Refer to the Related Links Section below for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable.


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]


[ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

Airflow and Power Supply Serviceability


Backplane

  • High performance
  • Monolithic
  • 6 slots
  • VXI P1 and P2 connectors The backplane features solid state automatic daisy-chain jumpering for the VMEbus grant and interrupt acknowledge lines, eliminating the need for hand selection of switch settings. The HP E1421B backplane is compatible with the HP backplane connector shield kit, P/N HP E1400-80920.

    Mechanical Specifications

    mm inches Height without bottom feet: 221.5 8.72 Height with bottom feet: 233.4 9.19 Width without side feet: 425.5 16.75 Width with side feet: 447.8 17.63 Depth with rear feet + power supply handles: 558.8 22.00 Weight: 13.9 kg / 30.6 lbs

    Power Specifications

    Power output: The power supply generates backplane logic signals ACFAIL* and SYSRESET* in full compliance with the VXI Specification, Revision 1.4. DC Output Voltage Pk Current at 55 °C IMP Dynamic Current IMD +5 V 45 A 5 A +12 V 8 A 2.5 A –12 V 8 A 2.5 A +24 V 8 A 4 A –24 V 8 A 4 A –5.2 V 40 A 5 A –2 V 15 A 3.5 A

    Usable power

    450 W maximum at 55 °C

    Power Supply Protection

    All outputs are protected from over-temperature, over-voltage, over-current, and short-to-ground.

    Power Input

    Input voltage: 100 Vac to 264 Vac Input frequency: 47 Hz to 66 Hz Inrush current: 40 A max

    Cooling

    Temperature rise: 10 °C (through the module for a 60 W module with typical density)

    Environmental and Regulatory

    Acoustic noise: Low-speed fan: 53 dBA sound pressure (at bystander position) High-speed fan: 59 dBA sound pressure (at bystander position)

    Shielding

    Intermodule: Gasketing per VXI Rev. 1.4, B.7.2.3. is provided. Backplane: Backplane Connector Shields per VXI Rev. 1.4, B.7.2.3 (available as Option 918 or as a separate accessory, HP E1421-80920) Intermodule chassis: Intermodule chassis shields per VXI Rev 1.4, B.7.3.4 (available as a separate product, HP E1409B)

    Electromagnetic Compliance

    To ensure compliance with RFI levels specified in standards EN55011 and CISPR11, the Backplane Connector shields must be installed in the mainframe. Order Option 918 to get shields factory installed. The HP E1409B C-Size Chassis Shield allows grounded shielding between mainframe slots in the HP E1401A/B and E1421B VXI Mainframes. This shield fits between slots – not using up a mainframe slot.

    VXI Characteristics

    VXI device type: Mainframe Data transfer bus: All per VXIbus specification, Rev. 1.4 Size: C Slots: 6 Connectors: P1/2 Shared memory: n/a VXI busses: All per VXIbus Standard Specification, Rev. 1.4

    Available Current

    IMP IMD +5 V: 45.00 5.00 +12 V: 8.00 2.50 –12 V: 8.00 2.50 +24 V: 8.00 4.00 –24 V: 8.00 4.00 –5.2 V 40.00 5.00 –2 V: 15.00 3.50

    Cooling/Slot

    Watts/slot: 60 W (10 °C rise) DeltaP mm H2O: n/a Air Flow liter/s: n/a

  • [ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

    HP E1421B      6-Slot, C-Size VXI Mainframe
      Opt 500      VXI Module Installation with standard Address
      Opt 908      Flange Kit
      Opt 909      Handle and Flange Kit
      Opt 915      Smoked Acrylic Door
      Opt 916      Recess Flange Mounting Kit
      Opt 918      VXI Backplane Connector Shield Kit
      Opt W01      3 year Return to HP to 1 year OnSite Warranty
    HP E1400-80920 Shield, Backplane Connector
    HP E1400-60202 Filler Panel 1 Slot
    HP E1421-65000 Flush Rack Flange Kit
    HP E1421-80916 Recess Flange Mounting Kit
    HP E1409B      Series C chassis shield for the E1401A
    HP 1494-0060   Rack Slide Kit
    HP 1494-0061   Rack Slide Kit for Non-HP Rack
    
    


    [ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

    HP E1421B Technical Specifications Datasheet ( PDF)

    If you do not have the Adobe Acrobat Reader necessary for viewing PDF documentation, download your free Acrobat Reader now. Get Acrobat

    [ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

    To help you make the right product choices

    [ Summary ][ Features ][ Specifications ][ Key Literature ][ Ordering ][ Assistance ][ Related ]

    Related Information:


    Related VXI Mainframes Family Specifications product datasheets:

    Related product families available online:



    Privacy Statement    Use of this site indicates that you accept the Terms of Use
    Contact HP Test & Measurement. (c) Copyright 1994 - 1998 Hewlett-Packard Company.

    Page Updated: Thursday February 18 07:19:54 UTC 1999