HP E1463A VXI 32-Channel 5 Amp, Form C Switch |
The HP E1463A 32-channel form C switch is a C-size, 1-slot, register-based VXI module. It is capable of carrying 5 Amp of current on a single channel for power-switching applications. These applications include process control, appliance pass/fail testing, and on/off control among many others.
This general-purpose switch generates low thermal offset voltage
(<3 µV typical), making it suitable for signal switching and
scanning applications. The HP E1463A comes with the HP QUIC screw
terminal block (optional solder eye connectors) for easy wiring.
Space to add series and shunt signal conditioning or
circuit-protection elements -- MOVs and fuses -- is available on the
terminal block. Extra screw terminal blocks can be purchased and
wired separately if multiple applications share the HP E1463A.
Note: Configuration software that allows you to easily select
compatible interfaces, controller platforms, and VXI test system
components is available on CD ROM. Order the
"Test System
and VXI Products Catalog and CD ROM" from
the Test & Measurement Catalogs available on this web site.
Input
Maximum voltage (C to NC or NO or any terminal-to-chassis): DC: 125 V (250 V non-switched) AC rms: 250 V AC peak: n/a Maximum current (non-inductive, per switch): DC: 5 A, (50 Adc or Aac rms per module) AC rms: 5 A, (50 Adc or Aac rms per module) Maximum power: Per switch: DC: 150 W AC: 1,250 VA Per module: DC: 1,500 W AC: 12,500 VA
DC
Maximum thermal offset: 7 µV (<3 µV typ) Closed channel resistance: Initial: <.25 Ohm (>100 mA) <20 Ohm (<100 mA) End of life: <2 Ohm (>100 mA) Insulation resistance (between any two points): <=40°C, <=95% RH: >10E8 Ohm <=40°C, <=65% RH: n/a <=25°C, <=40% RH: >10E9 Ohm
AC
Typical bandwidth (-3 dB): 10 MHz Crosstalk (dB, channel-to-channel): <10 kHz: <-83 <100 kHz: <-63 <1 MHz: <-43 <10 MHz: -- Crosstalk (dB, common-to-NO or NC): <10 kHz: <-80 <100 kHz: <-60 <1 MHz: <-40 <10 MHz: n/a Crosstalk (dB, module-to-module): <10 kHz: <-100 <100 kHz: <-100 <1 MHz: <-90 <10 MHz: n/a Closed channel capacitance: Ch-to-ch: 30 pF Ch-to-com: <40 pF Ch-to-guard: <25 pF
General Characteristics
Typical relay life (number of operations): No load: >5x10E7 Rated load: >3.5x10E4 (250 Vac, 5A, p.f.=0.4) >10E5 (250 Vac, 5A resistive) >10E5 (30 Vac, 5A L/R=7 ms) Time to close or open a channel (register programming): 16 ms Connector type, wire size: Screw: >=18 AWG(1.2 mm) Power up/down states: Normally open contact is open
VXI Characteristics
VXI device type: Register-based, A16, slave only Size: C Slots: 1 Connectors: P1/P2 Shared memory: None VXI busses: None C-size compatibility: n/a
Instrument Drivers
Click here for driver availability and downloading.Command module firmware: ROM Command module firmware rev: A.08 I-SCPI Win 3.1: Yes I-SCPI Series 700: Yes C-SCPI LynxOS: Yes C-SCPI Series 700: Yes HP VEE Drivers: Yes VXIplug&play Win Framework: Yes VXIplug&play Win95/NT Framework: Yes VXIplug&play HP-UX Framework: No (not available at time of publication)
Module Current
IPM IDM +5 V: 0.1 0.1 +12 V: 0.6 0.01
Cooling/Slot
Watt/slot: 10.00 deltaP mm H2O: 0.08 Air flow liter/s: 0.42
HP E1463A VXI 32-Channel 5 Amp, Form C Switch Opt 0B3 Service manual Opt W01 3-yr. return to HP to 1-yr. on-site warranty Opt A3G Solder eye terminals HP E1463-80011 Extra screw terminal blockHP E1463A Technical Specifications Datasheet
If you do not have the Adobe Acrobat Reader necessary for viewing this documentation, download your Free Acrobat Reader now. |
![]() |
Page Updated: Thursday June 19 16:15:17 UTC 1997