HP E1466A VXI 4x64 Relay Matrix |
The HP E1466A relay matrix is a C-size, 1-slot, register- based VXI module. This 4x64 matrix switches each crosspoint- both high and low. The HP E1466A module provides the best cost-per-crosspoint for large matrix applications. It features easy expansion to larger matrixes via a chaining cable that allows you to interconnect rows and columns on different modules. A full HP E1401B 13-slot mainframe can have up to 3072 2-wire crosspoints.
The HP E1466A shares the same switch card with the HP E1465A and
E1467A; each product’s unique terminal block determines the matrix
configuration. Therefore, you can change matrix topology simply by
plugging in the various terminal blocks, which can be obtained
separately. Creating a matrix as large as 4x256 requires three
matrix modules and interconnected rows and columns on the terminal
blocks. All of the HP E1465/66/67A matrix modules offer similar
densities, with different row/column sizes and identical
performance specifications. All specifications are identical for
this family, except for crosstalk.
Note: Configuration software that allows you to easily select
compatible interfaces, controller platforms, and VXI test system
components is available on CD ROM. Order the
"Test System
and VXI Products Catalog and CD ROM" from
the Test & Measurement Catalogs available on this web site.
Input (HP E1466A)
Maximum Voltage (any terminal to any other terminal chassis): DC: 200 V AC rms: 170 V Peak: 238 Vp-p Maximum Power: Per module: 62.5 VA (resistive load) Per channel: 30W
DC (HP E1465A)
Maximum Thermal Offset: 5 µV (per channel, differential Hi-Lo) Closed Channel Resistance (per channel): <4.0 ohms initially (worst crosspoint) <1.8 ohms initially (best crosspoint) <10.0 ohms end of relay life Insulation Resistance (between any two points): >10E8 ohms (<=40°C, <=95% RH) >10E9 ohms (<=25°C, <=40% RH) Minimum Bandwidth (-3 dB, ZL=ZX=50 ohms): 10 MHz
AC (HP E1466A)
AC specifications apply with no more than one crosspoint closed per row or column. Specifications are for 16x16 matrix, for Z(load)=Z(source)=50 ohms. Crosstalk(1) Within a Card (worst path) <10 kHz <100 kHz <1 MHz Closed Path to Closed Path (typical)(3) -66 dB -45 dB -29 dB Open Row to Open Row (typical)(3) -73 dB -52 dB -37 dB Open Row to Open Column (typical)(3) -84 dB -64 dB -47 dB Open Column to Open Column (typical)(3) -92 dB -70 dB -52 dB Module-to-Module(2) (represents 4x123 configuration) Closed Path to Closed Path (typical)(3) -66 dB -45 dB -29 dB Open Row to Open Row (typical)(3) -68 dB -46 dB -29 dB Open Row to Open Column (typical)(3) -84 dB -64 dB -48 dB Open Column to Open Column (typical)(3) -92 dB -71 dB -52 dB Closed Channel Capacitance: Hi to Lo: <270 pF Hi to Ground: <430 pF Lo to Ground: <440 pF NOTES: (1) Specifications are for worst crosspoint. Matrix expansion degrades crosstalk and bandwidth performance. (2) Chaining cable used to connect modules (HP P/N E1466-80002). (3) Typical is defined as the worst crosspoint test result from one or two matrix modules. If guaranteed specifications are necessary, contact your local sales representative. Minimum bandwidth (-3 dB, 50 Ohm): 10 MHz
General
Minimum Relay Life: No load 10E7 operations Screw Terminal Wire Size: 18 to 26 AWG (1.2, 0.9, 0.75, 0.6, 0.5 mm)
VXI Characteristics
VXI device type: Register-based, A16, slave only Size: C Slots: 1 Connectors: P1 Shared memory: None VXI busses: None C-size compatibility: n/a
Instrument Drivers
Click here for driver availability and downloading.Command module firmware: ROM Command module firmware rev: A.08 I-SCPI Win 3.1: Yes I-SCPI Series 700: Yes C-SCPI LynxOS: Yes C-SCPI Series 700: Yes HP VEE Drivers: Yes VXIplug&play Win Framework: Yes VXIplug&play Win95/NT Framework: Yes VXIplug&play HP-UX Framework: No (not available at time of publication)
Module Current
IPM IDM +5 V: 0.1 0.01 +12 V: 0.18 0.01
Cooling/Slot
Watt/slot: 5.00 deltaP mm H2O: 0.08 Air Flow liter/s: 0.42
HP E1466A VXI 4x64 Relay Matrix Opt 0B3 Service manual Opt W01 3-yr. return to HP to 1-yr. on-site warranty HP E1466-80001 Terminal block 4x64 relay matrix HP E1466-80002 Cable kit, daisy chainHPE1466A Technical Specifications Datasheet
If you do not have the Adobe Acrobat Reader necessary for viewing this documentation, download your Free Acrobat Reader now. |
![]() |
Page Updated: Thursday June 19 16:15:39 UTC 1997