HP E2270A 16-Ch Form A Switch M-Module |
The HP E2270A 16-Channel Form A Switch is a single-wide, register-based M-Module. It furnishes 16 independent SPST latching relays for general purpose signal switching and control of external devices. Use this M-Module when you need high integrity contacts or quality connections of non-multiplexed signals in your system.
Logic on the card provides for maskable interrupts (INTC type) when the requested relay movements have been completed. The module also has a FIFO for storing up to 8 relay operations. You can write rapid setup changes to the module and execute them with only one interrupt occurrence once the entire group of relay movements is complete.
With each M-Module having its own address within the HP E2251A M-Module
carrier, you have the flexibility to use the M-Modules in many
combinations. This flexibility allows you to get the amount of
functionality you need in smaller blocks, lowering your overall
system costs.
Input |
||||||||||||||||||||||||||||||||||||||||||||||||
DC: | 60 V/200 V (see note) | |||||||||||||||||||||||||||||||||||||||||||||||
AC rms: | 48 V/125 V (see note) | |||||||||||||||||||||||||||||||||||||||||||||||
AC peak: | 68 V/175V (see note) | |||||||||||||||||||||||||||||||||||||||||||||||
Maximum current (non-inductive): Per switch: |
2 A 2 A |
|||||||||||||||||||||||||||||||||||||||||||||||
Per module:
|
2 A 2 A |
|||||||||||||||||||||||||||||||||||||||||||||||
Maximum power: Per switch: |
50 W 50 VA |
|||||||||||||||||||||||||||||||||||||||||||||||
Per module:
|
200 W 200 VA |
|||||||||||||||||||||||||||||||||||||||||||||||
DC |
||||||||||||||||||||||||||||||||||||||||||||||||
Maximum thermal offset: | < 3 uV (typcial) | |||||||||||||||||||||||||||||||||||||||||||||||
End of life: | < 2 Ohms | |||||||||||||||||||||||||||||||||||||||||||||||
Insulation resistance (between any two points):
|
10E8 Ohms (typical) n/a 10E8 Ohms (typical) |
|||||||||||||||||||||||||||||||||||||||||||||||
AC |
||||||||||||||||||||||||||||||||||||||||||||||||
Typical bandwidth (-3dB): | > 10MHz (typical) | |||||||||||||||||||||||||||||||||||||||||||||||
Crosstalk (dB, channel-to-channel):
|
n/a <-64 dB(typical) <-44 dB(typical) <-24 dB(typical) |
|||||||||||||||||||||||||||||||||||||||||||||||
Closed channel capacitance:
|
<15 pF (typical) < 25 pF (typical) |
|||||||||||||||||||||||||||||||||||||||||||||||
General Characterstics |
||||||||||||||||||||||||||||||||||||||||||||||||
Relays: | 16 latching relays | |||||||||||||||||||||||||||||||||||||||||||||||
Typical relay life (number of operations):
|
n/a 10E5 |
|||||||||||||||||||||||||||||||||||||||||||||||
Time to close or open a channel (register programming): | 8 msec | |||||||||||||||||||||||||||||||||||||||||||||||
Connector type, wire size:
|
44 pin D-Sub n/a |
|||||||||||||||||||||||||||||||||||||||||||||||
Power up/down states: | latching relays retain last programmed state | |||||||||||||||||||||||||||||||||||||||||||||||
M-Module Characteristics |
||||||||||||||||||||||||||||||||||||||||||||||||
Output connector type: | two 44-pin D-Sub(female) | |||||||||||||||||||||||||||||||||||||||||||||||
Standard compliance: | IDENT, A08, D16, INTC | |||||||||||||||||||||||||||||||||||||||||||||||
Accessory: | 44-pin D-Sub (male) with plastic housing | |||||||||||||||||||||||||||||||||||||||||||||||
VXI Characterstics |
||||||||||||||||||||||||||||||||||||||||||||||||
VXI device type: | Register-based | |||||||||||||||||||||||||||||||||||||||||||||||
Data Transfer Bus: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
Size: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
Slots: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
Connectors: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
Shared Memory: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
VXI Busses: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
C-size compatibility: | Yes with E2251A | |||||||||||||||||||||||||||||||||||||||||||||||
Instrument Drivers |
||||||||||||||||||||||||||||||||||||||||||||||||
Command Module Firmware: | Downloadable | |||||||||||||||||||||||||||||||||||||||||||||||
Command Module Firmware Rev: | A.08 | |||||||||||||||||||||||||||||||||||||||||||||||
I-SCPI Win 3.1: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
I-SCPI Series 700: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
C-SCPI LynxOS: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
C-SCPI Series 700: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
HP VEE Drivers: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
VXI plug&play Win Framework: | n/a | |||||||||||||||||||||||||||||||||||||||||||||||
Yes | ||||||||||||||||||||||||||||||||||||||||||||||||
VXI plug&playHP-UX Framework | Yes | |||||||||||||||||||||||||||||||||||||||||||||||
Module Current
|
||||||||||||||||||||||||||||||||||||||||||||||||
|
HP E2270A 16-Ch Form A Switch M-Module Opt W01 3 yr. return to HP to 1 yr. OnSite warranty Opt 0B1 Add manual set
Page Updated: Thursday June 19 16:10:57 UTC 1997