Power: 480 W
Output voltage:
fixed mode: 0 - 60 V
SAS and table mode: Voc, max: 65V
Output current:
fixed mode: 0 - 8 A
SAS and table mode: Isc, max: 8A
Programming accuracy: at 25 degrees C ± 5 degrees C (SAS and table mode)
Voltage: 0.075% + 0.017% of rated voltage
Current: 0.2% + 0.25% of rated current
Ripple and Noise: (20 Hz to 20 MHz) with outputs ungrounded or
with either terminal grounded.
Fixed Mode:
Voltage: rms 12 mV
p-p 84 mV
Current: rms 2.4 mA
p-p 18 mA
Simulator and Table Mode:
Voltage: rms 16 mV
p-p 110 mV
Current: rms 4 mA
p-p 32 mA
Load/Line regulation: change in output voltage or current for any load or
line change within ratings.
Fixed Mode:
Voltage: 2 mV
Current: 1 mA
Simulator and Table Mode:
Current: 1 mA
Weight: Net, 25 kg (56 lbs); shipping, 29 kg (63 lbs)
Dimensions: 425.5 mm W x 132.6 mm H x 497.8 mm D (16.75 in x 5.25 in x 19.6 in)
HP E4350B Solar Array Simulator. Voc, max-65 Vac Opt 0BN Service Manual and extra Operating Guide Opt 100 87-106 Vac, 47 - 63 Hz Opt 220 191 - 233 Vac, 47 - 63 Hz Opt 240 209 - 250 Vac, 47 - 63 Hz Opt 1CM Rackmount Kit, HP p/n 5062-3977 Opt 1CP Rackmount Kit with Handles, HP p/n 5062-3983 Opt 0B0 Delete manual kit Accessories: HP 1252-3698 7-pin Analog Plug HP 1252-1488 4-pin Digital Plug HP 5080-2148 Serial Link Cable 2 m (6.6 ft) HP 1494-0059 Accessory Slide Kit
No literature is available online at this time.
To help you make the right product choicesCustomers outside the U.S. can obtain assistance through local HP DIRECT help.
Related Information:
Using Solar Array Simulators This paper describes solar array simulator (SAS) and how its powerful DSP generates the I-V curve to simulate solar panels.
Sequential Shunt Regulation This application note describes the sequential shunt regulation that is widely used for regulating the satellite bus voltage.
Request a copy of the Power Products Catalog
Related HP E4350 Series Solar Array Simulators product datasheets:

Page Updated: Friday February 12 02:09:56 UTC 1999